直肠间隔物在前列腺SBRT中减轻分次内运动:球囊、水凝胶与无间隔物比较
本回顾性研究分析了70例局限性前列腺癌患者共341个SBRT分次,比较球囊间隔物、水凝胶间隔物与无间隔物对分次内前列腺运动的影响。结果显示,球囊间隔物在3mm阈值下减少53%的偏差事件,水凝胶减少28%,球囊间隔物还显著降低主导振荡幅度和三维运动包络体积。
要点
- 球囊间隔物减少3mm阈值偏差事件53%,水凝胶减少28%。
- 球囊间隔物在各方向主导振荡幅度均小于无间隔物。
- 球囊间隔物三维运动包络体积显著小于无间隔物和水凝胶。
核心结论
- 直肠间隔物特别是可生物降解球囊与分次内前列腺运动减少相关。
- 间隔物设计可能具有潜在的运动稳定效应。
研究设计与样本
- 回顾性分析70例局限性前列腺癌患者的341个SBRT分次,采用连续超声追踪。
- 根据机构可用性和FDA批准时间线,患者接受球囊间隔物(118分次)、水凝胶间隔物(88分次)或无间隔物(135分次)。
临床怎么用
- 在前列腺SBRT中可考虑使用直肠间隔物,尤其是球囊间隔物,以减少分次内运动。
- 间隔物选择可能影响运动稳定性,需结合临床实际评估。
局限性
- 回顾性研究设计,间隔物分组基于机构可用性和FDA批准时间线,可能存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: This study aimed to compare the effects of biodegradable balloon and hydrogel perirectal spacers versus no spacer on prostate motion during stereotactic body radiation therapy (SBRT). METHODS AND MATERIALS: We analyzed 341 SBRT fractions with continuous ultrasound tracking in 70 patients treated for localized prostate cancer. Patients received a balloon spacer (118 fractions), a hydrogel spacer (88 fractions), or no spacer (135 fractions) based on institutional availability and U.S. Food and Drug Administration approval timeline. Motion was quantified using Poisson regression analysis of clinically meaningful deviation events (≥2-3 mm for ≥3 seconds), fast Fourier transform analysis of dominant oscillatory amplitudes, and 3-dimensional motion envelope volumes calculated from covariance-derived ellipsoids. RESULTS: At the 3 mm threshold, balloon spacers reduced deviation events by 53% (incidence rate ratio, 0.47; 95% CI, 0.31-0.69; P < .001) and hydrogel spacers by 28% (incidence rate ratio, 0.72; 95% CI, 0.55-0.93; P = .013) compared with no spacer. Balloon spacers demonstrated significantly smaller dominant oscillatory amplitudes across all spatial dimensions: antero-posterior (0.50 vs 0.73 mm, P = .005), superior-inferior (0.30 vs 0.46 mm, P = .005), and left-right (0.20 vs 0.27 mm, P = .064) versus no spacer. The 3-dimensional motion envelope volume was substantially reduced with balloon spacers (0.58 mm3) compared with no spacer (2.04 mm3, P = .002) or hydrogel (2.79 mm3, P < .001). CONCLUSIONS: In this retrospective SBRT cohort, rectal spacing, particularly with a biodegradable balloon, was associated with less intrafraction prostate motion. These findings suggest a potential motion-stabilizing effect of spacer design.
引用
- Tward BV, Szegedi M, Tward JD, et al. Intrafraction Motion Mitigation by Rectal Spacers in Prostate Stereotactic Body Radiation Therapy: Balloon, Hydrogel, and No-Spacer Comparison. Pract Radiat Oncol. 2026. PMID: 42142816. doi:10.1016/j.prro.2026.05.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。