MR引导前列腺SBRT的靶区分次内运动:自适应计划与实时运动管理的重要性
该研究在1.5 T MR-Linac上对212例临床局限型前列腺癌患者行5次SBRT,采用综合运动管理(CMM)连续追踪并门控分次内运动(IFM)。结果显示62.7%的分次因>1.5 mm的束前位移而进行自适应位置(ATP)计划校正,54.1%的分次出现持续>3 mm位移,21.7%出现>5 mm位移;ATS+ATP工作流与持续>3 mm运动几率降低相关(p=0.035),年龄较大与几率增加相关(p=0.011)。
要点
- 62.7%分次因>1.5 mm束前位移需ATP计划校正。
- 54.1%分次出现持续>3 mm位移,中位累计24秒。
- ATS+ATP工作流与持续>3 mm运动几率降低相关。
核心结论
- 前列腺在束前及束中可发生显著位移,常超过所用外扩边界,可能导致肿瘤欠剂量。
- 持续运动追踪与门控是减少IFM、提高治疗递送精度的重要工具。
研究设计与样本
- 212例临床局限型前列腺癌患者接受1.5 T MR-Linac上5次SBRT,IFM由CMM连续追踪并门控,束前位移通过束前MRI配准识别,多变量分析识别与IFM相关的变量。
主要发现
- 614个分次(62.7%)因>1.5 mm束前位移行ATP计划校正。
- 前后和头脚方向束前位移均值分别为2.2 mm和2.1 mm。
- 962个可评估分次中,中位束流时间为13.7分钟,平均占空比为95.8%。
- 520个分次(54.1%)出现持续>3 mm位移,中位累计持续时间24秒;209个分次(21.7%)出现>5 mm位移,中位持续时间12.4秒。
- ATS+ATP工作流与持续>3 mm运动几率降低相关(p=0.035),年龄较大与几率增加相关(p=0.011)。
临床怎么用
- 前列腺SBRT中应使用连续运动追踪与门控,并结合束前MRI配准行ATP校正以减少IFM。
- ATS+ATP工作流可能降低持续>3 mm运动风险,可考虑用于临床。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: This study evaluated the extent of prostate displacement during SBRT on an MRI Linac using comprehensive motion management (CMM) and identified variables associated with intrafraction motion (IFM). METHODS: 212 patients with clinically localized prostate cancer were treated with 5-fraction SBRT on a 1.5 T MR-Linac where IFM was continuously tracked and gated by CMM. Pre-beam positional shifts were identified from MRI registration prior to beam delivery. Intrafraction positional variability during beam delivery was evaluated, and multivariable analysis identified variables associated with IFM. RESULTS: In 614 fractions (62.7%), a > 1.5 mm pre-beam positional shift led to an adapt-to-position (ATP) plan correction. Mean anterior-posterior and superior-inferior pre-beam shifts were 2.2 mm and 2.1 mm, respectively. For 962 evaluable fractions, the median beam-on-time was 13.7 min with a mean duty cycle of 95.8%. Sustained > 3 mm displacement was observed in 520 fractions (54.1%) with a median cumulative duration of 24 s; >5 mm displacement was observed in 209 fractions (21.7%) with a median duration of 12.4 s. The ATS + ATP workflow was associated with reduced odds of sustained > 3 mm motion (p = 0.035), while older age was associated with increased odds (p = 0.011). CONCLUSIONS: Significant prostate shifts can occur immediately prior to and during radiation beam delivery, frequently exceeding applied margins and potentially leading to tumor underdosage. Continuous motion tracking and gating during prostate SBRT is an important tool in reducing IFM and enhance treatment delivery accuracy.
引用
- Zelefsky MJ, Chen T, Walters RD, et al. Intra-fraction target motion during MR-guided prostate stereotactic body radiotherapy: the importance of adaptive planning and real-time motion management. Radiother Oncol. 2026. PMID: 42150736. doi:10.1016/j.radonc.2026.111603
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。