文献速递消化道肿瘤放疗放疗物理与技术

显式束流几何建模提升食管癌放疗三维剂量预测精度

Explicit modeling of beam geometry improves three-dimensional dose prediction for esophageal cancer radiotherapy under heterogeneous beam configurations.
PubMed 文献 · Radiat Oncol · 2026-05-22

该回顾性研究纳入751例食管癌IMRT患者,构建仅基于解剖的剂量预测模型(ADP)与整合射线追踪束流几何的模型(AADP)。AADP将平均剂量误差从2.88%降至2.02%,等剂量体积Dice系数从0.90升至0.93,在罕见束流配置下平均误差为3.08%对4.52%,并缩短计划时间最多65%。

要点

  • 显式束流几何建模可降低食管癌IMRT剂量预测误差并提升等剂量空间相似度。
  • 在罕见束流配置下AADP鲁棒性优于仅解剖模型,平均误差3.08%对4.52%。
  • AADP辅助计划使 junior physicists 总计划时间从111.4分钟缩短至38.5分钟。

核心结论

  • 基于射线追踪的显式束流几何建模可提升食管癌IMRT三维剂量预测的准确性、鲁棒性与临床实用性。

研究设计与样本

  • 回顾性分析751例食管癌IMRT患者,构建共享AS-NeSt骨干的ADP与AADP两个模型。
  • 在独立测试集(n=100)、罕见束流配置队列(n=33)和临床验证队列(n=42)中以临床计划为参考基线进行评估。

主要发现

  • AADP较ADP显著降低多数靶区与危及器官的预测误差,平均剂量误差从2.88%降至2.02%。
  • 低至中等剂量区域(肺和心脏)改善明显,等剂量体积平均Dice相似系数从0.90升至0.93。
  • 罕见束流配置下AADP平均误差为3.08%,ADP为4.52%。
  • AADP辅助计划使 junior physicists 总计划时间从111.4分钟缩短至38.5分钟(最多缩短65%),减少迭代并改善物理师内部及之间剂量一致性。

临床怎么用

  • 可将治疗前可获取的归一化束流覆盖图与重叠图作为剂量预测模型输入,以提升计划效率与一致性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Deep learning-based 3D dose prediction boosts radiotherapy planning efficiency and consistency, yet most models rely solely on anatomical data and assume homogeneous beam configurations, impairing their robustness in esophageal cancer intensity-modulated radiotherapy (IMRT) with heterogeneous beam arrangements. This study explored whether explicit beam geometry modeling enhances voxel-level dose prediction accuracy, robustness in rare beam configurations, and clinical workflow efficiency. METHODS: A retrospective analysis was performed on 751 esophageal cancer IMRT patients. Two models with the identical AS-NeSt backbone were constructed: an anatomy-only dose prediction model (ADP) and an anatomy-and-angle-based model (AADP) integrating ray-tracing-derived beam geometry representations (normalized beam coverage and overlap maps) accessible in pre-planning. Model performance was assessed on an independent test set (n = 100), a rare-beam configuration cohort (n = 33) and a clinical validation cohort (n = 42), against clinical plans as the reference baseline. Evaluation was based on dosimetric metrics and isodose spatial similarity, along with an analysis of its robustness on unseen beam configurations and impact in a crossover clinical workflow study. RESULTS: Compared with ADP, AADP significantly reduced prediction errors for most targets and organs at risk, cutting average dosimetric error from 2.88% to 2.02%, with prominent improvements in low-to-intermediate dose regions (lung and heart). The mean Dice similarity coefficient of isodose volumes rose from 0.90 to 0.93. For rare beam configurations, AADP exhibited superior robustness (average error: 3.08% vs. 4.52%). Notably, AADP-assisted planning shortened total planning time by up to 65% (from 111.4 to 38.5 min for junior physicists), reduced iterations, and improved intra- and inter-physicist dose consistency. CONCLUSIONS: This study confirms explicit ray-tracing-based beam geometry modeling enhances the accuracy, robustness, and clinical utility of 3D dose prediction for esophageal cancer IMRT, supporting beam geometry as a critical component of clinically deployable, physics-informed dose prediction models.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Duan Y, Chen H, Wang H, et al. Explicit modeling of beam geometry improves three-dimensional dose prediction for esophageal cancer radiotherapy under heterogeneous beam configurations. Radiat Oncol. 2026. PMID: 42174687. doi:10.1186/s13014-026-02844-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。