固定配置与图像引导针插入在宫颈近距离放疗中的剂量学比较
本研究纳入FIGO IB2-IVa期宫颈癌患者46例,比较固定配置(FC)针插入与标准图像引导(SOC)针插入在近距离放疗中的剂量学与毒性。两组均无CTCAE 3-4级OAR毒性。
要点
- HRCTV、膀胱D2cc、直肠D2cc剂量学差异无统计学意义。
- 两组均未发生CTCAE 3-4级OAR毒性。
核心结论
- FC针插入法在宫颈近距离放疗中临床可行,毒性极小且剂量学结果与标准图像引导方法相当。
研究设计与样本
- 纳入FIGO IB2-IVa期宫颈癌患者46例,外照射后行Utrecht施源器间质近距离放疗28Gy/4次,分FC组与SOC组,允许交叉。
主要发现
- 两组均无患者发生CTCAE 3-4级OAR毒性。
关键数值与推荐
- FC组:6根侧针以2 cm深度插入,无图像引导;SOC组:CT引导针插入。
- 近距离放疗剂量方案为28Gy/4次。
临床怎么用
- 在资源有限环境中,FC针插入法可作为图像引导方法的可行替代,以减少医疗负担。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Brachytherapy is an integral part of cervical cancer management. In interstitial brachytherapy, image guided needle insertion can be logistically challenging in resource-limited settings. This study aimed to evaluate whether a fixed-configuration (FC) needle insertion method yields dosimetric results and toxicity profile comparable to the standard, image guided technique. METHODS AND MATERIALS: The study included cervical cancer patients, FIGO IB2-IVa, who underwent external beam radiation (EBRT) followed by interstitial brachytherapy, 28Gy/4 fractions, via Utrecht applicator. Patients were either assigned to an FC group, where 6 lateral needles were inserted at 2 cm depth without image guidance, or the standard of care (SOC) group, where CT guided needle insertion was done. Cross-over was permitted if needed. Planning a CT scan was done afterward in both groups. Per patient, dosimetric analysis was done in patients with a consistent technique throughout treatment. The dosimetric parameters for HR CTV D90 and organs at risk (OARs), that is, D2cc of bladder, rectum, and sigmoid colon, were analyzed and compared using Mann-Whitney U test. Patients were evaluated for posttreatment acute toxicity. RESULTS: 181 fractions were evaluated in a cohort of 46 patients. Per-fraction analysis (FC = 93, SOC = 88) revealed insignificant differences across HRCTV (P = .28), D2cc bladder (P = .98), and D2cc rectum (P = .37). D2cc sigmoid was significantly greater in the FC group (median D2cc = 4.79 Gy) than the SOC group (median D2cc = 4.36 Gy, P = .01). Per-patient analysis (FC = 17, SOC = 14) yielded insignificant dosimetric differences across the clinical target volume (P = .57), D2cc bladder (P = .440), D2cc rectum (P = .54), and D2cc sigmoid (P = .52). No patient in either group developed grade CTCAE 3-4 OAR toxicity. CONCLUSIONS: The FC needle insertion method is a clinically feasible option in cervical brachytherapy, yielding minimal toxicity and dosimetric outcomes comparable to the standard, image guided approach, thus offering a viable alternative that can reduce health care burden, especially in resource-limited settings.
引用
- Ejaz M, Khan MS, Baig AQ, et al. Dosimetric Comparison of Fixed-Configuration Versus Image Guided Needle Insertion in Cervical Brachytherapy. Pract Radiat Oncol. 2026. PMID: 41925665. doi:10.1016/j.prro.2026.02.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。