质子布拉格峰跟踪FLASH立体定向放疗可达到IMPT等效剂量学

FLASH Stereotactic radiosurgery for brain metastases using proton Bragg peak tracking can achieve IMPT equivalent dosimetry.
PubMed 文献 · Radiother Oncol · 2026-03-31

本研究在自研治疗计划平台中实现单能布拉格峰(SEBP)跟踪技术,对8例多发脑转移患者比较SEBP-FLASH与标准IMPT单次18 Gy(RBE)的剂量学。两种技术三维剂量分布相当且均满足临床约束,SEBP-FLASH计划中所有危及器官在5 Gy(RBE)剂量阈值下达到>97%的FLASH剂量率覆盖。

要点

  • SEBP-FLASH与IMPT的三维剂量分布相当,均满足临床约束。
  • SEBP-FLASH计划中所有危及器官在5 Gy(RBE)阈值下FLASH剂量率覆盖>97%。
  • 该技术为多发脑转移立体定向放疗提供兼顾肿瘤控制与正常组织保护的可能。

核心结论

  • SEBP-FLASH delivery provides conformal dose distributions suitable for stereotactic treatment of multiple brain metastases, with dosimetric parameters meeting clinical recommendations and achieving the dose rates required for the FLASH effect.
  • This approach shows promise in balancing effective tumor control with enhanced normal tissue protection, potentially reducing toxicities.

研究设计与样本

  • 研究在自研治疗计划平台中实现单能布拉格峰(SEBP)跟踪技术,SEBP使用回旋加速器的单能层、射程移位器和射程补偿器实现布拉格峰远端跟踪和超高剂量率(UHDR)照射。
  • 对8例多发脑转移患者比较标准IMPT与SEBP-FLASH递送单次18 Gy(RBE)的剂量学,采用剂量率体积直方图(DRVH)评估UHDR比例(V40Gy(RBE)/s)。

主要发现

  • 两种技术三维剂量分布相当,均产生适形剂量分布并保持在临床约束内。
  • SEBP-FLASH计划的UHDR评估显示,所有危及器官(包括正常脑组织和脑干)在5 Gy(RBE)剂量阈值下达到>97%的FLASH剂量率覆盖。

关键数值与推荐

  • SEBP-FLASH与IMPT均递送单次18 Gy(RBE)用于8例多发脑转移患者。
  • 所有危及器官在5 Gy(RBE)剂量阈值下FLASH剂量率覆盖>97%。
  • UHDR比例以V40Gy(RBE)/s评估。

临床怎么用

  • SEBP-FLASH可为多发脑转移立体定向放疗提供适形剂量分布并满足临床推荐。
  • 该技术可达到FLASH效应所需剂量率,有望在肿瘤控制与正常组织保护间取得平衡。

局限性

  • 本研究为自研平台上的概念验证,样本仅8例患者,尚未评估临床结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE/OBJECTIVES: Stereotactic radiosurgery (SRS) is a primary technique for treating brain metastasis, however it can be associated with loss of neurocognitive function and necrosis. FLASH radiotherapy has demonstrated superior normal tissue sparing, however its clinical feasibility for treating multiple brain metastases has not yet been assessed. This study aims to establish a proof of concept for applying this novel modality in brain metastases treatment. METHODS: We implemented a single-energy Bragg peak (SEBP) tracking technique into an in house treatment planning platform. SEBP uses a single-energy layer from the cyclotron, along with a range shifter and range compensator, to achieve Bragg peak distal tracking and enable ultra high dose rate (UHDR) delivery. Standard of care IMPT was compared with the SEBP-FLASH method for delivering a single 18 Gy(RBE) fraction in eight patients with multiple brain metastases. Dosimetric parameters were compared between IMPT and SEBP-FLASH and dose rate volume histograms (DRVH) were used to evaluate the UHDR ratio (V40Gy(RBE)/s) to determine treatment feasibility and potential benefits. RESULTS: The 3D dose distributions were comparable between the two techniques, with each producing conformal dose distributions while remaining within clinical constraints. UHDR evaluation of SEBP-FLASH plans demonstrated that all critical organs at risk (OARs), including normal brain tissue and the brainstem achieved (>97%) FLASH dose rate coverage at a dose threshold to 5 Gy(RBE). CONCLUSION: SEBP-FLASH delivery provides conformal dose distributions suitable for stereotactic treatment of multiple brain metastases, with dosimetric parameters meeting clinical recommendations and achieving the dose rates required for the FLASH effect. This approach shows promise in balancing effective tumor control with enhanced normal tissue protection, potentially reducing toxicities.