文献速递消化道肿瘤放疗放疗物理与技术

双能CT虚拟单能成像用于直肠癌放疗靶区勾画

Evaluation of dual-energy CT virtual monoenergetic imaging for target delineation in rectal cancer radiotherapy.
PubMed 文献 · Radiother Oncol · 2026-03-19

结果显示静脉期40 keV VMI图像质量优于常规120 kVp CT,与MRI勾画的GTV一致性更高(平均DSC 0.83 vs 0.67),观察者间一致性更好,头脚方向边界识别误差更小。

要点

  • 静脉期40 keV VMI的病灶对比度、对比噪声比和信噪比均显著高于常规120 kVp CT。
  • VMI与MRI勾画GTV的平均DSC为0.83,显著高于常规CT的0.67。
  • VMI的观察者间一致性优于常规CT,头脚方向边界误差显著减小。

核心结论

  • 静脉期40 keV双能CT虚拟单能成像在客观和主观图像质量上均优于常规120 kVp CT,可显著提高直肠癌放疗GTV勾画准确性、观察者间一致性和头脚方向边界识别。

研究设计与样本

  • 评估40-200 keV虚拟单能图像和合成120 kVp CT的病灶对比度、对比噪声比和信噪比,确定最佳单能图像。
  • 三名放射肿瘤科医生独立评估最佳单能图像、常规120 kVp CT和T2WI-MRI的图像质量及肿瘤勾画,并以T2WI-MRI为参考勾画GTV。

主要发现

  • 静脉期40 keV VMI的病灶对比度、对比噪声比和信噪比显著高于常规120 kVp CT(p < 0.0001)。
  • VMI与MRI勾画GTV的平均DSC为0.83 ± 0.04,显著高于常规CT与MRI的0.67 ± 0.10(p < 0.0001)。
  • 配准精度高的患者中,VMI与MRI的DSC提高至0.86 ± 0.01。
  • VMI的观察者间一致性为0.82 ± 0.05,优于常规CT的0.76 ± 0.07(p < 0.001)。
  • 与常规CT相比,VMI显著减小头侧和尾侧边界误差。

关键数值与推荐

  • 最佳单能图像为静脉期40 keV VMI。
  • VMI主观整体图像质量评分与MRI相当(p = 0.040),肿瘤勾画评分与MRI相当(p = 0.449)。

临床怎么用

  • 静脉期40 keV双能CT虚拟单能成像可作为直肠癌放疗GTV勾画的可靠影像工具,有助于平衡肿瘤控制与正常组织保护。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the image quality of dual-energy CT (DECT) virtual monoenergetic imaging (VMI) in rectal cancer and to investigate its value for gross tumor volume (GTV) delineation in radiotherapy. MATERIALS AND METHODS: Twenty-nine patients with rectal cancer receiving neoadjuvant chemoradiotherapy were prospectively enrolled. Each patient underwent contrast-enhanced DECT and 3.0 T MRI on the same day. Lesion contrast (LC), contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were assessed for VMI from 40-200 keV and synthetic 120 kVp CT (S120kVp), with the optimal monoenergetic image (VMIEopt) determined accordingly. Three radiation oncologists independently assessed VMIEopt, S120kVp, and T2WI-MRI for overall image quality and tumor delineation, and delineated GTVs. T2WI-MRI served as the reference. Dice similarity coefficient (DSC) was used to compare delineation performance, with further analysis of interobserver agreement and cranial-caudal margin identification. RESULTS: Venous-phase 40 keV VMI (VMIEopt) showed significantly higher LC, CNR, and SNR than S120kVp (p < 0.0001). Subjective scores of VMIEopt were comparable with MRI for both overall image quality (p = 0.040) and tumor delineation (p = 0.449). The concordance between VMIEopt- and MRI-defined GTVs was significantly higher than that between S120kVp- and MRI-defined GTVs (mean DSC: 0.83 ± 0.04 vs 0.67 ± 0.10, p < 0.0001). In patients with high registration accuracy, the DSC for the VMIEopt-MRI comparison further improved to 0.86 ± 0.01. Interobserver agreement was superior for VMIEopt compared with S120kVp (0.82 ± 0.05 vs 0.76 ± 0.07, p < 0.001). Cranial and caudal margin errors were also significantly reduced when using VMIEopt compared to S120kVp. CONCLUSION: Venous-phase 40 keV DECT VMI demonstrated objectively and subjectively superior image quality compared with S120kVp, significantly improving GTV delineation accuracy, interobserver consistency, and cranial-caudal margin identification. It may serve as a reliable imaging tool to balance tumor control and normal tissue sparing in rectal cancer radiotherapy.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Liu K, Wang W, Wang P, et al. Evaluation of dual-energy CT virtual monoenergetic imaging for target delineation in rectal cancer radiotherapy. Radiother Oncol. 2026. PMID: 41864515. doi:10.1016/j.radonc.2026.111488

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。