文献速递乳腺癌放疗放疗物理与技术

俯卧位同步双侧乳腺癌放疗的临床结局与摆位重复性

Clinical Outcomes and Setup Reproducibility in Patients Receiving Synchronous Bilateral Breast Radiation in the Prone Position.
PubMed 文献 · Pract Radiat Oncol · 2026-03-11

双侧全乳放疗最常见剂量为40.5 Gy并瘤床同步加量至48 Gy,部分乳腺照射为30 Gy/5次或40.05 Gy/15次。双侧全乳放疗患者急性皮炎发生率高于部分乳腺照射,摆位位移多在亚厘米或亚度水平,仅10%患者GaF胶片显示野重叠。

要点

  • 俯卧位双侧乳腺放疗可行,摆位位移多小于1厘米或1度,GaF胶片野重叠率仅10%。
  • 双侧全乳放疗患者急性2级皮炎发生率17.7%、3级2%,高于部分乳腺照射。
  • 胸骨区急性皮炎6例中仅2例GaF胶片显示重叠,提示重叠不能完全解释 midline 皮炎。

核心结论

  • 俯卧位同步双侧乳腺癌放疗可行,摆位位移和野重叠率低,但双侧全乳放疗患者急性皮炎发生率高于部分乳腺照射。

主要发现

  • 双侧全乳放疗最常见剂量为40.5 Gy并瘤床同步加量至48 Gy,部分乳腺照射为30 Gy/5次(4例)或40.05 Gy/15次(1例)。
  • 发生2级(17.7%)和3级(2%)皮炎的患者除1例外均接受双侧全乳放疗。
  • 6例患者出现胸骨区急性皮炎,其中2例GaF胶片显示重叠。
  • 20例有晚期毒性随访的患者中25%发生晚期1至2级皮炎(20%接受全乳放疗),1例出现局部和远处复发。

关键数值与推荐

  • 双侧全乳放疗最常见剂量40.5 Gy,瘤床同步加量至48 Gy;部分乳腺照射30 Gy/5次或40.05 Gy/15次。
  • 2014年后前5次治疗放置GaF胶片评估野重叠,持续重叠时触发重新模拟定位或重新计划。

临床怎么用

  • 俯卧位可用于同步双侧乳腺癌放疗,摆位重复性良好,但双侧全乳放疗需关注急性皮炎风险。
  • GaF胶片可用于评估野重叠,但胸骨区皮炎并非均与胶片可见重叠相关。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Radiation therapy (RT) positioning and planning are vital to minimizing toxicity in patients with synchronous bilateral breast cancer (SBBC). We studied clinical outcomes and setup reproducibility in SBBC patients treated in the prone position. METHODS AND MATERIALS: This retrospective study analyzed SBBC patients treated prone between 2012 and 2022. Demographics, clinical RT dose/field, dosimetry, on-treatment imaging, toxicity, and outcomes data were collected. RT delivery was standardized, with the left breast treated first. After 2014, radiochromic (GaF) films were placed for fractions 1 to 5 to evaluate field overlap, prompting resimulation or replanning if consistent overlap was detected. Positional shifts during setup were collected for bilateral whole breast irradiation (WBI) and partial breast irradiation (PBI). RESULTS: Forty-five patients were included. Median age was 67 years, and median follow-up was 64 months. Thirty-five, 5, and 5 patients received bilateral WBI (1 with low axilla), bilateral PBI, and a combination of WBI and PBI, respectively. The most common WBI dose was 40.5 Gy, with a simultaneous tumor bed boost to 48 Gy. PBI patients received 30 Gy in 5 fractions (n = 4) or 40.05 Gy in 15 fractions (n = 1). All patients who developed grade 2 (17.7%) and grade 3 (2%) dermatitis received bilateral WBI except for 1. Six patients had acute dermatitis in the sternal area, with overlap on GaF seen in 2 patients. Of 20 patients with late toxicity follow-up, 25% had late grade 1 to 2 dermatitis (20% received WBI). One patient recurred locally and distantly. Mean positional shifts were mostly subcentimeter or subdegree. Only 10% of patients had field overlap on GaF. CONCLUSIONS: To our knowledge, this is the first study examining patients treated for SBBC in the prone position. Prone bilateral RT is feasible with minimal shifts and overlap. However, higher rates of acute dermatitis occurred in bilateral WBI patients (vs PBI), and overlap was not seen on GaF in all patients who developed midline dermatitis.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Shah A, Galavis P, Morris S, et al. Clinical Outcomes and Setup Reproducibility in Patients Receiving Synchronous Bilateral Breast Radiation in the Prone Position. Pract Radiat Oncol. 2026. PMID: 41825687. doi:10.1016/j.prro.2026.02.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。