文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

Barrigel与SpaceOAR直肠间隔物在前列腺癌放疗中的真实世界对比分析

Real-World Data on Barrigel and SpaceOAR Rectal Spacers in Prostate Cancer Radiation Therapy: A Comparative Analysis.
PubMed 文献 · Adv Radiat Oncol · 2025-12-28

SpaceOAR中位体积更大(13.80 cc vs 5.10 cc,P<.01),更易获得较高间隔物质量评分(SQS),并在部分剂量体积参数上实现更低的直肠受照体积。校正间隔物体积后,Barrigel在6–13 cc体积范围内对20次分割患者的部分直肠剂量学结果更优。

要点

  • SpaceOAR中位体积13.80 cc大于Barrigel的5.10 cc,且更易获得较高SQS评分。
  • SpaceOAR在20次分割的v60、v46、v38、v30及5次分割的v30、v20上直肠受照体积更低。
  • 校正体积后Barrigel在6–13 cc范围内20次分割的v57、v54更优,且直肠壁浸润发生率更低(0 vs 2.44%)。

核心结论

  • 真实世界数据显示SpaceOAR因置入体积更大而获得更好的剂量学结果。
  • 在相似置入体积下,Barrigel相比SpaceOAR实现更低的直肠受照体积。
  • 剂量学结果更可能受置入体积而非对称性影响,SQS评分方法可能比FV评分更有用。
  • Barrigel的直肠壁浸润发生率低于SpaceOAR。

研究设计与样本

  • 多中心回顾性分析纳入2017至2023年接受放疗的前列腺癌患者。
  • 每例多参数磁共振成像由2名独立观察者进行直肠间隔置入评分。

主要发现

  • SpaceOAR中位体积13.80 cc大于Barrigel中位体积5.10 cc(P<.01)。
  • SpaceOAR更可能获得更高SQS(5次分割OR 6.25;>5次分割OR 2.16;P<.01)。
  • SpaceOAR在20次分割的v60、v46、v38、v30(P<.01均)及5次分割的v30(P=.04)、v20(P=.01)直肠受照体积更低。
  • 校正间隔物体积后,Barrigel在20次分割患者6–13 cc体积范围内v57(P=.01)、v54(P=.01)剂量学结果更优。
  • 较高SQS与更好剂量学结果相关(P<.05);FV评分在各评估剂量水平无类似单调趋势(v36 P=.10、v32 P=.26、v30 P=.45)。

关键数值与推荐

  • SpaceOAR中位体积13.80 cc,Barrigel中位体积5.10 cc(P<.01)。
  • SpaceOAR较高SQS的OR:5次分割6.25,>5次分割2.16(P<.01均)。
  • SpaceOAR直肠壁浸润7/287(2.44%),Barrigel无发生。
  • Barrigel在6–13 cc体积范围20次分割v57(P=.01)、v54(P=.01)更优。

临床怎么用

  • 选择直肠间隔物时需考虑置入体积对剂量学的影响,SpaceOAR较大体积可能带来更好直肠保护。
  • 在相似置入体积下Barrigel可能提供更优的直肠剂量学结果,且直肠壁浸润风险更低。
  • SQS评分方法或比FV评分更有助于评估剂量学结果。

局限性

  • 本研究为回顾性分析,可能存在选择偏倚和信息偏倚。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: : Hydrogel rectal spacers are in widespread and routine clinical use for prostate cancer radiation therapy. Theses spacers separate the prostate from the rectum, thereby reducing the radiation dose to the rectum. Two major hydrogels are in use, SpaceOAR and Barrigel, yet there are no real-world data comparing these two. This study aims to compare these gels with respect to quality of insertion and dosimetric outcomes. METHODS AND MATERIALS: A multicenter retrospective analysis was performed on all men with prostate cancer undergoing radiation therapy from 2017 to 2023. Demographic, radiation therapy, and magnetic resonance imaging details were imported for analysis. Each multiparametric magnetic resonance imaging was scored on rectal spacing placement by 2 independent observers. RESULTS: Eight hundred twenty-two patients were included for dosimetric and 605 for quality of insertion analysis. The median SpaceOAR volume (13.80 cc) was larger than the median Barrigel volume (5.10 cc) (P < .01). SpaceOAR was more likely to achieve a higher Spacer Quality Score (SQS) compared to Barrigel (5-fraction odds ratio [OR], 6.25; >5 fractions OR, 2.16; P < .01 for both respectively). SpaceOAR achieved lower irradiated rectal volumes for 20 fractions, at v60, v46, v38, and v30 (P < .01 for all) and 5 fractions, v30 (P = .04), v20 (P = .01). After accounting for spacer volume, Barrigel achieved better rectal dosimetric outcomes for 20 fraction patients compared to SpaceOAR for volumes between 6 and 13 cc, v57 (P = .01), v54 (P = .01). Higher SQS correlated with improved dosimetric outcomes (P < .05), whereas no similar monotonic trend was observed with the Fischer-Valuck (FV) score across evaluated dose levels, including v36 (P = .10), v32 (P = .26), and v30 (P = .45). Incidence of rectal wall infiltration among SpaceOAR patients was 7/287 (2.44%) compared to none for Barrigel. CONCLUSIONS: Real-world data show that SpaceOAR achieves better dosimetry than Barrigel likely due to larger insertion volumes. At similar insertion volumes, Barrigel achieves lower irradiated rectal volumes compared to SpaceOAR. Dosimetric outcomes are more likely impacted by volume rather than symmetry of insertion. The SQS scoring method may have better utility than the FV scoring method for assessing dosimetric outcomes. Our data also indicate that Barrigel has a lower incidence of rectal wall infiltration compared with SpaceOAR.

来源:Adv Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Prusty S, Cho D, Thong K, et al. Real-World Data on Barrigel and SpaceOAR Rectal Spacers in Prostate Cancer Radiation Therapy: A Comparative Analysis. Adv Radiat Oncol. 2025. PMID: 41716956. doi:10.1016/j.adro.2025.101989

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。