自动化MR-only放疗在头颈癌治疗中优于CT放疗并减少人工操作时间
本研究评估头颈癌自动化MR-only放疗工作流的可行性,该工作流包括基于零回波时间的合成CT用于剂量计算和基于T2w的自动OAR勾画。
要点
- 自动化MR-only勾画精度优于临床CT勾画(DSC 0.79 vs 0.67)。
- MR-only剂量计算误差小于临床工作流(+0.34 Gy vs -1.39 Gy)。
- 自动化MR-only工作流可减少头颈放疗准备工作量。
核心结论
- 自动化MR-only头颈放疗工作流比标准CT临床工作流更准确,证明其减少治疗准备工作量的可行性。
主要发现
- 自动MR-only勾画的DSC为0.79,临床CT勾画为0.67,95% Hausdorff距离分别为4.0 mm和5.8 mm(p值<0.001)。
- 自动MR-only放疗的平均剂量计算误差为+0.34 Gy,临床工作流为-1.39 Gy(p值<0.01)。
关键数值与推荐
- DSC 0.79 vs 0.67;95% Hausdorff距离4.0 vs 5.8 mm(p<0.001);平均剂量计算误差+0.34 Gy vs -1.39 Gy(p<0.01)。
临床怎么用
- 自动化MR-only工作流可替代计划CT和手动OAR勾画,减少头颈放疗准备工作量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Cancer incidence is expected to increase in Europe by 18% in eighteen years. To account for the increasing patient numbers, the workload per patient needs to be reduced. One step towards future-proof radiotherapy is automated MR-only radiotherapy as it could eliminate the need for (i) a planning CT and (ii) for manual organ at risk (OAR) delineations. The aim of this study was to evaluate the feasibility of an automated MR-only workflow for head-and-neck radiotherapy. METHOD: Automated MR-only radiotherapy consisted of a Zero-Echo-Time-based synthetic CT for dose calculations and automated T2w-based OAR delineations. Automated MR-Only RT was compared to the clinical workflow consisting of CT-based dose calculation and CT-based OAR delineations. Both approaches were benchmarked to a gold standard consisting of the planning CT for dose calculations and manual delineations on the T2w MR scan. Dice similarity coefficients (DSC), 95% Hausdorff distances and absolute DVH metrics were compared between the clinical and MR-only workflow using a linear mixed-effect model. A p-value < 0.05 was deemed significant. RESULTS: Seventeen head-and-neck cancer patients were included. The automated MR-only delineations were more accurate compared to the clinical CT delineations (DSC of 0.79 vs. 0.67; 95% Hausdorff distance 4.0 vs 5.8 mm (p-values < 0.001)). The average dose calculation errors of the automated MR only RT were smaller than the clinical workflow (+0.34 Gy vs. -1.39 (p-value < 0.01)). DISCUSSION: The automated MR-only head-and-neck radiotherapy workflow was more accurate than the standard CT based clinical workflow, demonstrating the feasibility of automated MR-only RT to decrease the workload for head-and-neck RT treatment preparation.
引用
- Lauwers I, Capala M, Kaushik S, et al. Automated MR-only radiotherapy outperforms CT-based radiotherapy and decreases hands-on time for head-and-neck cancer treatment. Clin Transl Radiat Oncol. 2026. PMID: 41732216. doi:10.1016/j.ctro.2026.101122