文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

环形机架系统上前列腺癌缺氧靶向剂量雕刻放疗的剂量学可行性

Dosimetric Feasibility of Dose-Painting Radiation Therapy for Targeting Hypoxia in Prostate Cancer on a Novel Ring Gantry Radiation Therapy System.
PubMed 文献 · Adv Radiat Oncol · 2025-11-29

研究基于7例中危前列腺癌患者的氟米索硝唑PET缺氧显像,在RefleXion环形机架系统上制定剂量雕刻IMRT计划,分别测试常规分割、中度大分割和高度大分割三种处方对肿瘤及缺氧区同步加量。结果显示7例患者均达到处方剂量并满足危及器官剂量限值,证明该技术剂量学可行。

要点

  • 7例中危前列腺癌患者均实现处方剂量覆盖,同时满足危及器官剂量限值。
  • 基于氟米索硝唑PET定义的缺氧区可在RefleXion系统上实现同步加量。
  • 研究测试了常规分割、中度大分割和高度大分割三种剂量雕刻方案。

核心结论

  • 在RefleXion治疗计划系统上,对前列腺癌肿瘤区及缺氧区进行剂量提升在剂量学上可行,且不突破危及器官剂量限值。

研究设计与样本

  • 选取7例来自Programme d'Action Intégré de Recherche-prostate研究的中危前列腺癌患者,均接受外照射放疗且治疗前氟米索硝唑PET显示肿瘤摄取。
  • GTV基于MRI勾画,缺氧区基于氟米索硝唑PET摄取在PTV内勾画。
  • 在RefleXion治疗计划系统研究版上制定IMRT计划,测试三种处方方案。

主要发现

  • 7例患者均达到处方剂量,同时遵守危及器官常规剂量限值。

关键数值与推荐

  • 常规分割方案:PTV 77 Gy/35次,GTV同步加量至95 Gy/35次,缺氧区加量至118 Gy/35次。
  • 中度大分割方案:PTV 60 Gy/20次,GTV加量至67 Gy/20次,缺氧区加量至91 Gy/20次。
  • 高度大分割方案:PTV 40 Gy/5次,GTV加量至50 Gy/5次,缺氧区加量尽可能高。

临床怎么用

  • 该计划系统可在满足危及器官剂量限值的前提下,对前列腺癌肿瘤及缺氧区实施同步剂量提升。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Hypoxia is a well-known major factor contributing to the radioresistance of prostate cancer, which could be counteracted by increasing the dose. This study aimed to demonstrate the dosimetric feasibility of a dose-painting radiation therapy plan for prostate cancer, using a novel ring gantry system, based on the localization of tumoral and hypoxic areas. METHODS AND MATERIALS: Seven patients from the Programme d'Action Intégré de Recherche-prostate study, who underwent external-beam radiation therapy for intermediate-risk prostate cancer and exhibited pretherapeutic fluromisonodazole positron emission tomography (PET) uptake in the tumor, were selected. The gross tumor volume (GTV) was delineated on the magnetic resonance imaging, and the hypoxic region within the planning target volume was delineated based on fluromisonodazole PET uptake. Intensity modulated radiation therapy planning was performed based on 3 different prescriptions: standard fractionation (77 Gy in 35 fractions to the planning target volume), with an integrated boost of 95 Gy and 118 Gy in 35 fractions to the GTV and the hypoxic region, moderate hypofractionation (60 Gy in 20 fractions) with a boost of 67 Gy and 91 Gy to the GTV and the hypoxic region, and high hypofractionation (40 Gy in 5 fractions) with a boost of 50 Gy to the GTV and as high as possible to the hypoxic region. Planning was performed on the research version of the RefleXion treatment planning system. RESULTS: We achieved the prescribed dose in all 7 patients while respecting the usual dose limits for organs at risk. CONCLUSIONS: This study demonstrated the dosimetric feasibility of dose escalation in both the tumor and hypoxic regions in patients with prostate cancer using the RefleXion treatment planning system, without compromising the dose limits for organs at risks.

来源:Adv Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Perennec T, Al Feghali KA, de Jong D, et al. Dosimetric Feasibility of Dose-Painting Radiation Therapy for Targeting Hypoxia in Prostate Cancer on a Novel Ring Gantry Radiation Therapy System. Adv Radiat Oncol. 2025. PMID: 41541754. doi:10.1016/j.adro.2025.101940

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。