文献速递乳腺癌放疗放疗物理与技术

优化左侧乳腺癌放疗深吸气屏气患者筛选的快速策略

Optimizing Deep Inspiration Breath-Hold Patient Selection in Left Breast Cancer Radiation Therapy: A Rapid Screening Strategy.
PubMed 文献 · Pract Radiat Oncol · 2026-01-15

本研究提出一种基于高性能DIBH-CT合成与定量剂量预测的筛选方法,用于左侧乳腺癌放疗中判断患者是否适合深吸气屏气(DIBH)。回顾性评估178例左侧乳腺癌放疗患者,合成预测DIBH-CT的图像平均绝对误差从178.49 HU降至55.19 HU,放疗策略筛选准确率达86.7%(13/15),预测结果与实际DIBH治疗结果高度一致。

要点

  • 合成预测DIBH-CT可显著降低图像平均绝对误差并提升轮廓配准精度。
  • 以FB-MHD>4 Gy需≥30%降低、≤4 Gy需≥50%降低为阈值筛选DIBH适合患者。
  • 策略筛选准确率达86.7%(13/15),预测与实际DIBH治疗结果高度一致。

核心结论

  • 所提出的快速筛选策略可用于评估左侧乳腺癌放疗患者是否适合DIBH,有望优化临床流程并减轻患者与医护负担。

研究设计与样本

  • 回顾性研究,评估178例接受左侧乳腺癌放疗的患者。
  • 构建两阶段模型:先由自由呼吸CT(FB-CT)经注意力U-Net生成合成DIBH-CT(sDIBH-CT),再用FB-CT与患者特异性DIBH正交投影重训练获得精炼sDIBH-CT。
  • 将FB-CT配准至精炼sDIBH-CT,利用形变向量场获得最终预测DIBH-CT(pDIBH-CT)及相关轮廓,并由剂量预测模型估计pDIBH-CT的平均心脏剂量(MHD)。

主要发现

  • 生成pDIBH-CT后,FB-CT与DIBH-CT之间的平均绝对误差从178.49 ± 41.95 HU降至55.19 ± 14.10 HU。
  • Dice相似系数:CTV从0.50 ± 0.19升至0.87 ± 0.05,PTV从0.59 ± 0.17升至0.89 ± 0.04,心脏从0.79 ± 0.05升至0.92 ± 0.01,肺从0.81 ± 0.04升至0.96 ± 0.01。
  • 放疗策略筛选准确率达86.7%(13/15),预测结果与实际DIBH治疗结果高度一致。

关键数值与推荐

  • DIBH适合患者的MHD降低阈值:FB-MHD >4 Gy者需DIBH下MHD降低≥30%,FB-MHD ≤4 Gy者需降低≥50%。

临床怎么用

  • 可利用FB-CT合成预测DIBH-CT并预测MHD,按FB-MHD阈值快速筛选适合DIBH的左侧乳腺癌放疗患者,减少额外DIBH-CT扫描。

局限性

  • 原文未报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The deep inspiration breath-hold (DIBH) technique for left breast cancer reduces cardiac radiation exposure but requires additional DIBH computed tomography (CT) scans to confirm patient suitability, increasing radiation dose and costs. We propose an innovative screening approach using high-performance DIBH-CT synthesis and quantitative dose prediction. METHODS AND MATERIALS: A 2-stage model was first developed: (1) a synthetic DIBH-CT (sDIBH-CT) was generated from free-breathing CT (FB-CT) via an attention U-Net, and (2) the synthetic model was retrained using FB-CT and patient-specific DIBH orthogonal projections of test patients to obtain a refined sDIBH-CT. The FB-CT was then registered to the refined sDIBH-CT and the consequent deformation vector field was used to obtain the final predicted DIBH-CT (pDIBH-CT) and associated contours. A dose prediction model estimated the mean heart dose (MHD) for pDIBH-CT. Registration accuracy was quantified by the Dice similarity coefficient, while image quality was assessed using the mean absolute error. Furthermore, MHD reduction thresholds were established to stratify DIBH-suitable patients: patients with FB-MHD >4 Gy required ≥30% MHD reduction with DIBH, whereas those with FB-MHD ≤4 Gy required ≥50% reduction. The retrospective study was evaluated using 178 patients treated with left-sided breast radiation therapy. RESULTS: The mean absolute error between FB-CT and DIBH-CT decreased from 178.49 ± 41.95 Hounsfield units (HU) to 55.19 ± 14.10 HU after generating pDIBH-CT. The Dice similarity coefficient increased from 0.50 ± 0.19 to 0.87 ± 0.05 for CTV, 0.59 ± 0.17 to 0.89 ± 0.04 for PTV, 0.79 ± 0.05 to 0.92 ± 0.01 for the heart, and 0.81 ± 0.04 to 0.96 ± 0.01 for the lungs. The accuracy of the radiation therapy strategy screening reached 86.7% (13/15), with the predicted outcomes closely matching the actual DIBH treatment results. CONCLUSIONS: We propose a rapid screening strategy for assessing DIBH suitability for patients treated with left-sided breast radiation therapy. This strategy has the potential to greatly optimize clinical workflow and reduce the burden on both patients and health care providers.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Lyu T, Zhang Y, Dong J, et al. Optimizing Deep Inspiration Breath-Hold Patient Selection in Left Breast Cancer Radiation Therapy: A Rapid Screening Strategy. Pract Radiat Oncol. 2026. PMID: 41547467. doi:10.1016/j.prro.2026.01.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。