前列腺癌在线自适应放疗中CTV-to-PTV外扩是否过大?微观病灶分布对治疗边界需求的影响
该研究基于组织病理学概率分布模拟前列腺内微观卫星灶,评估其空间分布对CTV-to-PTV外扩的影响。结果显示,在系统误差Σ=0.5mm、随机误差σr=1.5mm时,CTVprostate需3mm外扩,而CTV卫星灶仅需0-1mm;σr=2.7mm时,CTVprostate需5mm,多数卫星灶定义仅需2-3mm。结论认为若GTV有充分外扩覆盖,在线自适应放疗中CTV-to-PTV外扩可减少约2mm。
要点
- 微观病灶空间分布影响外扩需求,CTV卫星灶所需外扩小于整个前列腺CTV。
- 系统误差0.5mm、随机误差1.5mm时,前列腺CTV需3mm,卫星灶仅需0-1mm。
- 若GTV有充分外扩,在线自适应前列腺癌放疗CTV-to-PTV外扩可减少约2mm。
核心结论
- 若GTV被充分外扩覆盖,前列腺癌在线自适应放疗中CTV-to-PTV外扩可减少约2mm。
研究设计与样本
- 定义44cm3前列腺为CTVprostate,基于组织病理学概率分布采样微观卫星灶(数量1-10个、大小0.02-0.2cm3)定义CTVsatellites。
- 创建0-5mm均匀剂量分布,从3D高斯分布采样几何误差模拟5分次在线自适应治疗,确定使90%模拟中95%处方剂量覆盖CTVsatellites的PTV外扩。
主要发现
- 系统误差宽度Σ=0.5mm、随机误差宽度σr=1.5mm时,CTVprostate外扩为3mm,各CTVsatellites定义外扩为0-1mm。
- σr=2.7mm时,CTVprostate需5mm外扩,除最有利和最不利的CTVsatellites定义外均需2-3mm。
关键数值与推荐
- PTV外扩标准为确保90%模拟中95%处方剂量覆盖CTVsatellites。
- Σ=0.5mm、σr=1.5mm时,CTVprostate外扩3mm,CTVsatellites外扩0-1mm。
- σr=2.7mm时,CTVprostate外扩5mm,多数CTVsatellites定义外扩2-3mm。
临床怎么用
- 在线自适应前列腺癌放疗中,若GTV已有充分外扩,可考虑将CTV-to-PTV外扩减少约2mm。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Planning target volume (PTV) margin recipes assume all parts of the target are equally important. For the prostate clinical target volume (CTV) this is invalid. We evaluated the impact of the spatial probability distribution of microscopic disease in the prostate on CTV-to-PTV margins. MATERIALS AND METHODS: A prostate with a volume of 44 cm3 was defined as CTVprostate. Homogenous dose distributions were created with margins ranging 0-5 mm. The gross tumor volume (GTV) was assumed covered with a separate margin. Microscopic satellites were sampled within the CTVprostate from a histopathology-based probability distribution for a range of numbers (1-10) and sizes (0.02-0.2 cm3) to define CTVsatellites. Geometric errors were sampled from a 3D Gaussian distribution, simulating online adaptive treatment of 5 fractions. Each CTV was shifted with respect to the dose according to each total error. The PTV margin ensuring 95 % of the prescribed dose to the CTVsatellites in 90 % of simulations was determined and compared with CTVprostate. RESULTS: For systematic errors with width (Σ) 0.5 mm and random errors with width (σr) 1.5 mm, the margin for the CTVprostate was 3 mm, whereas for each definition of CTVsatellites this margin was 0-1 mm. For σr = 2.7 mm, a margin of 5 mm was adequate for the CTVprostate and 2-3 mm for all except the most favourable and unfavourable CTVsatellites definition. CONCLUSION: The CTV-to-PTV margins used in online adaptive radiotherapy for prostate cancer can be reduced by ∼2 mm, if the GTV is covered with an adequate margin.
引用
- Dassen MG, van Herk M, Witte MG, et al. Are the CTV-to-PTV margins currently used in online adaptive radiotherapy for prostate cancer too large? The impact of the distribution of microscopic disease on treatment margin requirements. Radiother Oncol. 2025. PMID: 41423135. doi:10.1016/j.radonc.2025.111351
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。