文献速递头颈部肿瘤放疗放疗物理与技术

头颈癌自动与手动IMPT计划的盲法临床评估

Qualitative Blinded Clinical Assessment of Automated and Manual IMPT Plans for Head and Neck Cancer.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2025-12-19

回顾性纳入30例接受手动IMPT计划治疗的头颈癌患者,用Erasmus-iCycle生成全自动IMPT计划,由3名经验丰富的头颈放疗医生盲法评估。

要点

  • 30例自动IMPT计划均被3名放疗医生评为临床可接受
  • 28/30例中医生一致偏好自动计划,手动计划从未被偏好
  • 靶区覆盖等效,自动计划靶区适形性和危及器官保护更优

核心结论

  • 全自动IMPT计划在头颈癌中均被经验丰富的放疗医生认为临床可接受,且几乎全部病例被一致偏好于手动计划,差异有统计学意义。

研究设计与样本

  • 回顾性纳入30例接受手动IMPT计划治疗的头颈癌患者,用Erasmus-iCycle生成全自动IMPT计划,采用相同临床4野配置和剂量约束。
  • 3名经验丰富的头颈放疗医生独立盲法评估自动与对应手动计划的临床可接受性和偏好。
  • 采用配对McNemar检验评估观察者间偏好差异,广义线性混合模型评估对自动计划的总体偏好。

主要发现

  • 30例自动IMPT计划均被所有3名医生评为临床可接受,手动计划中28/30例被所有3名医生评为临床可接受。
  • 28/30例中医生一致偏好自动计划(每对观察者间P=1.00),其余2例中1名医生无偏好,手动计划从未被偏好。
  • 靶区覆盖被认为等效,自动计划在靶区适形性和串联及并联危及器官保护方面通常被评为更优。

关键数值与推荐

  • 处方剂量:原发肿瘤7000 cGy(相对生物效应),双侧选择性淋巴结体积5425 cGy(相对生物效应)。
  • 自动计划使用Erasmus-iCycle生成,采用相同临床4野配置和剂量约束。

临床怎么用

  • 全自动IMPT计划可作为头颈癌临床可接受的计划选项,在多数病例中医生偏好自动计划而非手动计划。
  • 自动计划在靶区适形性和危及器官保护方面通常更优,支持其临床推广潜力。

局限性

  • 回顾性研究,样本量30例,来自单一机构经验。
  • 仅评估临床可接受性和偏好,未报告长期疗效或毒性结局。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To clinically validate fully automated intensity-modulated proton therapy (IMPT) planning for head and neck cancer (HNC) through blinded comparison with manual plans by experienced radiation oncologists (ROs). METHODS AND MATERIALS: Thirty patients with HNC treated with a manually created IMPT plan were retrospectively included. Dose prescription was 7000 cGy (relative biologic effectiveness) to the primary tumor and 5425 cGy (relative biologic effectiveness) to the bilateral elective nodal volumes. Fully automated IMPT plans were generated using Erasmus-iCycle, applying the same clinical 4-beam configuration and dose constraints. Three experienced HNC ROs independently assessed the automated and corresponding manual plans in a blinded manner. Each RO evaluated both plans, blinded to the planning method, to determine clinical acceptability and indicate their preference, if any. Interobserver differences in preference were evaluated using pairwise McNemar tests. A generalized linear mixed model was used to assess overall preference for automated plans. RESULTS: All 30 automated IMPT plans were considered clinically acceptable, whereas 28 of the 30 manual plans were rated clinically acceptable by all 3 ROs. In 28 out of 30 cases, the ROs unanimously (P = 1.00 between each pair of observers) preferred the automated plan. In the remaining 2 cases, 1 of the 3 ROs had no preference. The manual plan was never preferred. The overall preference for automated plans over no preference was statistically significant (P< .001). Target coverage was considered equivalent, whereas target conformality and sparing of both serial and parallel organs at risk were generally rated superior in the automated plans. CONCLUSIONS: All fully automated IMPT plans for HNC were considered clinically acceptable by experienced HNC ROs. Automated plans were unanimously preferred over manually created plans in nearly all cases, with statistical significance, highlighting the clinical potential of automated IMPT planning tools.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Huiskes M, Astreinidou E, de Jong M, et al. Qualitative Blinded Clinical Assessment of Automated and Manual IMPT Plans for Head and Neck Cancer. Int J Radiat Oncol Biol Phys. 2025. PMID: 41420630. doi:10.1016/j.ijrobp.2025.11.029

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。