文献速递头颈部肿瘤放疗放疗物理与技术

直立位提升头颈部碳离子固定束放疗射束角度优化与危及器官保护

Upright positioning enhances beam angle optimization and organ sparing in head and neck carbon-ion radiotherapy with fixed-beam systems.
PubMed 文献 · Radiat Oncol · 2025-12-02

结果显示U15在稳健性与危及器官保护间平衡最佳,S15为实用替代,S0与U45分别因稳健性差和脑干剂量高而不推荐。

要点

  • 直立位前向15°(U15)在稳健性与危及器官保护间平衡最佳。
  • 仰卧位15°斜角(S15)可作为实用替代方案。
  • 仰卧位0°(S0)与直立位45°(U45)分别因稳健性差和脑干剂量高不推荐。

核心结论

  • 直立位前向15°(U15)射束配置在稳健性与危及器官保护之间取得最佳平衡,是首选方案。

研究设计与样本

  • 计划在RayStation(v10B)中生成,考虑±3 mm摆位不确定度与±3.5%射程不确定度。

主要发现

  • 所有计划达到可比的名义靶区覆盖与相似CI值。
  • S15较S0稳健性显著改善(DVH带ΔD95%=0.5 Gy(RBE)、ΔV95%=1.4%;最差情况ΔD95%=0.3 Gy(RBE)、ΔHI=0.01、ΔCI=0.02,均p<0.05)且危及器官剂量更低(耳蜗28.4 vs. 30.6 Gy(RBE)、腮腺13.5 vs. 18.5 Gy(RBE)、脑干D1cc 40.1 vs. 41.7 Gy(RBE),均p<0.001)。
  • U15稳健性与S15相当,耳蜗(18.5 vs. 28.4 Gy(RBE),p<0.001)与腮腺(11.9 vs. 13.5 Gy(RBE),p<0.05)保护进一步改善。
  • U45稳健性与危及器官保护最高,但脑干D1cc显著升高至50.9 Gy(RBE)(p<0.05)。

关键数值与推荐

  • 推荐U15作为首选射束配置,S15作为实用替代方案,不推荐S0与U45。

临床怎么用

  • 在固定束碳离子放疗系统中,头颈部肿瘤可优先考虑直立位前向15°射束以优化稳健性与危及器官保护。
  • 若直立位不可行,仰卧位15°斜角射束可作为替代选择。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Carbon-ion radiotherapy (CIRT) for head and neck tumors is typically delivered in the supine posture using fixed beam lines, which limits beam angle selection. Combining upright posture with fixed beam lines offers expanded angular access and potential dosimetric advantages, yet optimal angle configurations remain unclear. This study identifies optimal beam angles in head and neck CIRT by comparing dosimetry and robustness of upright and supine plans for fixed-beam systems, thereby supporting beam angle optimization and clinical implementation of upright treatment in fixed-beam systems. METHODS: Twenty patients with head and neck cancer were retrospectively robustly optimized using four beam configurations: horizontal beams at 0° (S0) and with a 15° superior-oblique tilt (S15) in the supine posture, anterior beams at 15° (U15) and 45° (U45) in the upright posture. Plans were generated in RayStation (v10B) accounting for ± 3 mm setup and ± 3.5% range uncertainties. Target coverage (D95%, D2%, V95%, conformity index [CI], homogeneity index [HI]), plan robustness (DVH bands, worst-case scenario), and organ-at-risk (OAR) dosimetry (mean dose to cochleae and parotid glands, and brainstem D1cc) were compared. Statistical analyses used paired t-tests or Wilcoxon signed-rank tests. RESULTS: All plans achieved comparable nominal target coverage and similar CI values. S15 showed significantly improved robustness (DVH band ΔD95% = 0.5 Gy(RBE), ΔV95% = 1.4%; worst-case ΔD95% = 0.3 Gy(RBE), ΔHI = 0.01, ΔCI = 0.02, all p < 0.05) and lower OAR doses versus S0 (cochlea: 28.4 vs. 30.6 Gy(RBE), parotid: 13.5 vs. 18.5 Gy(RBE), brainstem D1cc: 40.1 vs. 41.7 Gy(RBE), all p < 0.001). U15 exhibited comparable robustness to S15 with further reductions in cochlea (18.5 vs. 28.4 Gy(RBE), p < 0.001) and parotid sparing (11.9 vs. 13.5 Gy(RBE), p < 0.05). U45 showed the highest robustness and OAR sparing, except for the brainstem, where D1cc was significantly increased (50.9 Gy(RBE), p < 0.05). CONCLUSIONS: The anterior beams at 15°in the upright setup (U15) showed the best balance of robustness and OAR sparing, making it the preferred option. The 15°-angled supine setup (S15) is a practical alternative. S0 and U45 are not recommended due to inferior robustness and higher brainstem dose, respectively.