弥散加权成像用于宫颈癌根治性放化疗及图像引导自适应近距离治疗中肿瘤区勾画
六名医师(三名专家、三名住院医师)在三个时间点勾画。结果显示DWI引导可显著改善专家间一致性,并提升住院医师与专家共识的符合度,尤其在近距离治疗时。
要点
- DWI引导可降低宫颈癌GTV勾画的观察者间变异。
- DWI对经验较少的医师获益更明显,轮廓更接近专家共识。
- DWI引导改善了近距离治疗前与治疗时肿瘤体积的相关性。
核心结论
- 将DWI纳入勾画流程可降低专家和住院放射肿瘤科医师的观察者间变异。
- DWI引导尤其使经验较少的医师通过额外功能信息获得更接近专家共识的轮廓。
研究设计与样本
- 六名医师(三名专家、三名住院医师)在诊断时、近距离治疗前、近距离治疗前应用器在位三个时间点勾画GTV。
- 勾画分别基于单独T2加权图像和T2加权联合DWI(b=800smm-2)引导。
- 以专家共识作为参考标准,采用STAPLE算法。
- 采用 conformity index、Dice-Sørensen系数和Hausdorff距离评估观察者间一致性。
主要发现
- DWI引导显著改善专家间一致性:诊断时 conformity index 从0.62升至0.70(p<0.05),近距离治疗时从0.33升至0.39(p<0.05)。
- 对住院医师,DWI引导增强与专家共识的一致性,尤其在近距离治疗时Dice系数中位增加9%(p<0.05),Hausdorff距离中位减少1.3 mm(p<0.05)。
- DWI引导改善了两组医师在近距离治疗前与治疗时之间的肿瘤体积相关性。
临床怎么用
- 在宫颈癌根治性放化疗及图像引导自适应近距离治疗的GTV勾画中可考虑纳入DWI(b=800smm-2)辅助。
- 对经验较少的医师,DWI引导有助于获得更接近专家共识的轮廓。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: Accurate gross tumor volume (GTV) delineation is critical for successful radiochemotherapy and image-guided adaptive brachytherapy (BT) in cervical cancer. This study investigated whether diffusion-weighted imaging (DWI) improves GTV delineation accuracy compared to T2-weighted (T2w) MRI alone, across different physician experience levels. MATERIALS AND METHODS: Twenty-seven patients with locally advanced cervical carcinoma undergoing primary radiochemotherapy were analyzed. Six physicians (three experts, three residents) delineated GTVs at three time points: diagnosis (init), pre-brachytherapy (preBT), and pre-brachytherapy with applicator in situ (BT). Segmentations were performed using T2w images alone and T2w plus DWI (b=800smm-2) guidance. Expert consensus served as reference standard using STAPLE algorithm. Inter-observer agreement was assessed using conformity index, Dice-Sørensen coefficient, and Hausdorff distance. RESULTS: DWI guidance significantly improved inter-observer agreement among experts at init (conformity index: 0.62→ 0.70, p<0.05) and BT (0.33→ 0.39, p<0.05) time points. For residents, DWI guidance enhanced agreement with expert consensus, particularly during BT, with significant improvements in Dice coefficient (median increase 9%, p<0.05) and reduced Hausdorff distance (median decrease 1.3 mm, p<0.05). Tumor volume correlation between preBT and BT time points improved with DWI guidance for both groups. CONCLUSION: Incorporating DWI into the segmentation workflow reduces inter-observer variability for both expert and resident radiation oncologists. DWI guidance particularly benefits less experienced physicians, enabling them to achieve contours closer to expert consensus standards through additional functional information.
引用
- Zimmermann L, Knäusl B, Knoth J, et al. Diffusion weighted imaging for gross tumor volume delineation in primary radiochemotherapy and image guided adaptive brachytherapy for cervical cancer. Radiother Oncol. 2025. PMID: 41297112. doi:10.1016/j.radonc.2025.111306
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。