文献速递消化道肿瘤放疗放疗物理与技术

在线剂量自适应放疗显著缩小直肠癌照射体积

Online dose-adaptive radiotherapy considerably reduces irradiated volume in rectal cancer radiotherapy.
PubMed 文献 · Radiother Oncol · 2025-11-22

该回顾性研究纳入14例接受1.5 T MR-Linac在线自适应放疗(OART)、方案为5×5 Gy的直肠癌患者,在分次1–4累积实际交付剂量的基础上优化分次5计划,实现在线剂量自适应放疗(DART)。结果显示DART较常规OART使CTV D99%平均降低0.5 Gy,但超过90%患者靶区覆盖仍符合方案要求,同时临床PTV外1 cm环的中位剂量降低3.6 Gy,接受95%处方剂量的患者体积平均减少32%(221 cm3)。

要点

  • DART技术上可行,累积交付的CTV剂量可满足方案覆盖要求。
  • 临床PTV外1 cm环中位剂量较常规OART降低3.6 Gy。
  • 接受95%处方剂量的患者体积平均减少32%(221 cm3)。

核心结论

  • 在线剂量自适应放疗在直肠癌中技术可行,能在保证累积CTV剂量的同时显著保护健康组织。

研究设计与样本

  • 回顾性纳入14例接受1.5 T MR-Linac在线自适应放疗、方案为5×5 Gy的直肠癌患者。
  • 分次1–4按1 mm PTV margin生成每日计划,并将实际交付剂量经形变配准累积至分次5的适配扫描。
  • 分次5以分次1–4累积剂量为背景优化至处方剂量,并与采用临床PTV margin的常规OART累积交付剂量比较。

主要发现

  • DART较常规OART使CTV D99%平均降低0.5 Gy,但超过90%患者靶区覆盖符合方案要求。
  • 临床PTV外1 cm环的中位剂量降低3.6 Gy。
  • 接受95%处方剂量的患者体积平均减少32%(221 cm3)。

关键数值与推荐

  • 分次1–4采用1 mm PTV margin生成每日计划。
  • DART后CTV D99%平均降低0.5 Gy,超过90%患者靶区覆盖充足。
  • 临床PTV外1 cm环中位剂量降低3.6 Gy,接受95%处方剂量的体积平均减少32%(221 cm3)。

临床怎么用

  • 可考虑在MR-Linac平台对直肠癌短程放疗实施在线剂量自适应,以缩小照射体积并保护健康组织。

局限性

  • 回顾性设计,样本量为14例直肠癌患者,需进一步前瞻性验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: Online adaptive radiotherapy (OART) allows for a reduction of geometric uncertainties and therefore smaller PTV margins. In this work we take the next step and introduce online dose-adaptive radiotherapy (DART), where the treatment plan is adapted not only to the geometry of the day but also to the accumulated dose delivered in previous fractions. MATERIALS AND METHODS: 14 rectal cancer patients that were treated with OART with 5x5Gy on a 1.5 T MR-Linac were retrospectively included. For fractions 1-4, a daily treatment plan using 1 mm PTV margin was generated. Actual delivered dose was estimated by recalculation of this plan on the post-treatment scan. By means of deformable image registration, the delivered doses were accumulated on the adaptation scan of fraction 5. For fraction 5, a plan was optimized to the prescribed dose, using the accumulated dose of fractions 1-4 as background. Target coverage and irradiated volume of the final accumulated delivered dose was compared with the accumulated delivered dose from conventional OART using clinical PTV margins. RESULTS: After dose accumulation, DART led to a mean decrease in CTV D99% of 0.5 Gy compared to conventional OART, however, conform protocol, target coverage was sufficient in >90 % of patients. The median dose in the 1 cm ring around the clinical PTV was reduced by 3.6 Gy and the patient volume that received 95 % of the prescribed dose decreased by 32 % (221 cm3) on average. CONCLUSION: Online DART is technically feasible, achieving adequate delivered accumulated CTV dose, while substantially sparing the healthy tissue.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Schröder L, van der Bijl E, Wiersema L, et al. Online dose-adaptive radiotherapy considerably reduces irradiated volume in rectal cancer radiotherapy. Radiother Oncol. 2025. PMID: 41285184. doi:10.1016/j.radonc.2025.111302

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。