螺旋容积调强弧形放疗用于全脑放疗同步推量治疗多发脑转移
本研究回顾性纳入10例多发脑转移(40-120个)患者,比较螺旋容积调强弧形放疗(SVMAT)与螺旋断层放疗(HT)及分段容积调强弧形放疗(PVMAT)的计划质量。结果显示SVMAT靶区覆盖与适形性与HT及PVMAT无显著差异,但右侧海马、视神经和视交叉保护优于HT,且部分旋转次数下出束时间短于HT。
要点
- SVMAT靶区覆盖与适形性与HT及PVMAT无显著差异。
- SVMAT对右侧海马、视神经和视交叉保护优于HT。
- SVMAT在6、8、10次旋转时出束时间短于HT。
核心结论
- 对于全脑放疗同步推量,SVMAT相比HT获得更好的计划质量和更高的出束效率,与PVMAT计划质量相似。
研究设计与样本
- 回顾性纳入10例既往接受HT全脑放疗同步推量(40 Gy全脑,60 Gy转移灶,20次)的多发脑转移(40-120个)患者。
- SVMAT计划使用DeepPlan 1.3设计,治疗机为NeuRT Aurora,床在指定多次机架旋转后移出再移入,旋转次数6-16次。
- 基于包含20项指标的计划质量度量(PQM)比较SVMAT、HT和PVMAT计划。
主要发现
- 全脑和转移灶的靶区覆盖与适形指数(CI)在SVMAT与HT或SVMAT与PVMAT之间均无显著差异(p > 0.05)。
- SVMAT相比HT改善了右侧海马、视神经和视交叉的保护(p < 0.05),但与PVMAT在OAR保护上无显著差异(p > 0.05)。
- SVMAT计划(6、8、10、12、14、16次旋转)的平均PQM总分分别为51.70 ± 8.14、53.24 ± 5.84、53.64 ± 7.16、54.24 ± 7.06、54.60 ± 6.30和55.05 ± 6.18分。
- HT的平均PQM得分为38.18 ± 5.48分,显著低于SVMAT计划(p < 0.05);PVMAT平均得分为54.34 ± 6.48分,与SVMAT无显著差异(p > 0.05)。
- SVMAT在6、8、10次旋转时的出束时间分别为271.5 ± 53.7 s、310.3 ± 42.9 s、359.6 ± 34.4 s,短于HT的393.0 ± 25.0 s(p < 0.05);SVMAT 6次旋转也短于PVMAT的312.6 ± 53.7 s(p < 0.05)。
关键数值与推荐
- 处方剂量:全脑40 Gy,转移灶60 Gy,分20次。
- PQM包含20项指标,评分越高计划质量越好。
临床怎么用
- 对于多发脑转移的全脑放疗同步推量,SVMAT可作为一种计划质量优于HT且出束效率较高的技术选择。
- 在需要保护海马、视神经和视交叉等危及器官时,SVMAT相比HT具有优势。
- SVMAT与PVMAT计划质量相似,可根据临床需求和设备条件选择。
局限性
- 本研究为回顾性研究,样本量仅10例。
- SVMAT计划为基于既往HT病例的重新设计,非前瞻性随机比较。
- 研究仅评估计划质量和出束时间,未报告临床疗效或毒性结果。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Spiral volumetric modulated arc therapy (SVMAT) is an integrated radiation therapy technique with longitudinal couch movement to generate a spiral/helical trajectory. This approach combines the merits of volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT). This study aimed to investigate the treatment planning of SVMAT for whole-brain radiotherapy (WBRT) with simultaneous integrated boost (SIB) for a large number (> 40) of metastases. MATERIALS AND METHODS: Ten patients with multiple brain metastases (40-120 metastases) were retrospectively enrolled. These patients had previously received treatment with HT using the WBRT + SIB technique. Prescribed doses of 40 Gy for the whole brain and 60 Gy for the metastases were delivered in 20 fractions. In this study, SVMAT plans were designed using DeepPlan (version 1.3, Wisdom Tech., Hefei, Anhui, China) as the treatment planning system for the radiotherapy machine NeuRT Aurora (Neusoft IntelliRay Technology, Shenyang, Liaoning, China). In all SVMAT plans, the patient couch was set to move out after specified multiple gantry rotations and then move in within a single treatment fraction. The number of gantry rotations ranged between 6 and 16. These SVMAT plans were compared with HT and piecewise VMAT (previously proposed PVMAT) based on a plan quality metric (PQM) comprising 20 metrics. RESULTS: For target coverage and conformity index (CI) of whole brain and metastases, no significant differences were observed between the SVMAT&HT or between SVMAT&PVMAT plans (p > 0.05). The sparing of right hippocampus, optic nerves and optic chiasm were improved using the SVMAT plan compared to the HT plan (p < 0.05). However, no significant difference was observed between the SVMAT and PVMAT plans for OAR sparing (p > 0.05). The mean total scores of PQM were 51.70 ± 8.14 (mean ± standard deviation), 53.24 ± 5.84, 53.64 ± 7.16, 54.24 ± 7.06, 54.60 ± 6.30, and 55.05 ± 6.18 points for SVMAT plans with gantry rotations of 6 8, 10, 12, 14, and 16, respectively. The average score for HT was 38.18 ± 5.48 points, which was significantly lower than that for the SVMAT plans (p < 0.05). Furthermore, the mean score for PVMAT was 54.34 ± 6.48 points, and no significant differences were observed between SVMAT and PVMAT (p > 0.05). The beam delivery time was shorter for SVMAT with 6 (271.5 ± 53.7 s), 8(310.3 ± 42.9 s), and 10(359.6 ± 34.4 s) rotations compared to HT (393.0 ± 25.0 s) (p < 0.05) and also shorter for SVMAT with six rotations compared to PVMAT (312.6 ± 53.7 s) (p < 0.05). CONCLUSIONS: For WBRT + SIB, SVMAT achieved improved plan quality and higher delivery efficiency compared with HT and had similar plan quality compared with PVMAT.
引用
- Xu Y, Miao J, Dai J, et al. Spiral volumetric modulated arc therapy for whole-brain radiotherapy with simultaneous integrated boost to multiple brain metastases. Radiat Oncol. 2025. PMID: 41219976. doi:10.1186/s13014-025-02742-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。