SFRT可显著缩短从会诊到开始治疗的时间,剂量学不确定性总体较低但胸部病例变异较大,有限数据显示毒性可控且症状缓解有效。

要点

  • SFRT可显著缩短会诊至治疗开始的时间间隔。
  • 诊断CT剂量学不确定性总体低,胸部病例变异较高。
  • 患者选择通常排除陡峭剂量梯度、再程放疗或需固定装置者。

核心结论

  • SFRT为姑息放疗提供实用高效的替代方案,在选定患者中可加快治疗启动并优化资源利用,不损害安全性与疗效。

主要发现

  • SFRT与常规流程相比显著缩短从会诊到治疗开始的时间间隔。
  • 使用诊断CT的剂量学不确定性总体较低,胸部病例变异较高。
  • 有限临床结局数据显示毒性谱良好且症状缓解有效。

关键数值与推荐

  • 患者选择通常排除涉及陡峭剂量梯度、再程放疗或需要固定装置的治疗。

临床怎么用

  • 在选定姑息患者中可考虑SFRT以加快治疗启动,但胸部病灶与复杂计划需谨慎。

局限性

  • 纳入研究为回顾性与前瞻性队列,临床结局数据有限,需更多具有稳健临床终点的前瞻性研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Cancer incidence continues to rise globally, with nearly half of patients requiring radiotherapy. Simulation-free radiotherapy (SFRT) using diagnostic CT scans instead of dedicated planning CTs is a streamlined alternative that may reduce patient visits and shorten time to treatment without impacting quality of care. This systematic review evaluates the practical aspects, dosimetric accuracy, and clinical outcomes of SFRT in palliative radiotherapy. METHODS: Following PRISMA guidelines, PubMed and Embase were searched for publications on SFRT using multiple search terms. Included studies reported clinical or logistical endpoints such as treatment timing, toxicity, dosimetric errors, and patient-reported outcomes. RESULTS: Eleven studies met inclusion criteria, comprising retrospective and prospective cohorts with patient numbers ranging from 10 to 1000. SFRT was associated with significantly reduced intervals from consultation to treatment start compared to conventional workflows. Dosimetric uncertainties using diagnostic CT scans were generally low, with higher variability observed in thoracic cases. Patient selection typically excluded treatments involving steep dose gradients, reirradiation, or requiring immobilization devices. Limited clinical outcome data showed favourable toxicity profiles and effective symptom relief. CONCLUSIONS: SFRT offers a practical, efficient alternative for palliative radiotherapy, enabling faster treatment initiation and optimized resource use without compromising safety or efficacy in selected patients. The overall dosimetric accuracy appears acceptable for most cases, though caution is advised for thoracic lesions and complex treatment plans. Additional prospective studies with robust clinical endpoints are needed to further validate the role of SFRT in palliative radiotherapy.

来源:Clin Transl Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Zwahlen DR, Brodmann S, Förster R, et al. Simulation-free palliative radiotherapy using diagnostic CT scans- is less more? A systematic review. Clin Transl Radiat Oncol. 2025. PMID: 41080988. doi:10.1016/j.ctro.2025.101053

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。