优化CBCT在线自适应放疗流程以减少医师参与
该研究基于34例前列腺癌患者的前瞻性2期试验数据,分析613个分次的CBCT在线自适应放疗流程。结果显示5影响者流程将手动靶区修正降至11%的分次,医师靶区审核时间最短为2.5分钟,提示优化流程可减少医师参与并支持技师驱动模式。
要点
- 5影响者流程手动靶区修正仅11%,显著低于3影响者51%和2影响者61%。
- 5影响者流程医师靶区审核中位时间2.5分钟,短于3影响者5.0分钟和2影响者5.6分钟。
- 优化流程可能支持类似标准图像引导放疗的技师驱动模式。
核心结论
- 在前列腺癌患者中,优化CBCT在线自适应放疗流程可减少医师参与需求。
研究设计与样本
- 分析前瞻性2期试验中34例前列腺癌患者接受CBCT在线自适应放疗(62 Gy/20次)的数据,比较2、3、5影响者三种流程。
主要发现
- 共分析613个分次,5影响者流程手动靶区修正为11%的分次,3影响者为51%,2影响者为61%(P < .001)。
- 各流程中位会话时长为24.0分钟(IQR,22.0-28.0)。
- 5影响者流程中位靶区审核时间2.5分钟,短于3影响者5.0分钟(P < .001)和2影响者5.6分钟(P = .002)。
- 84%的患者认为治疗时间耐受良好。
关键数值与推荐
- 5影响者流程手动靶区修正11%的分次,3影响者51%,2影响者61%(P < .001)。
- 5影响者流程中位靶区审核时间2.5分钟,3影响者5.0分钟(P < .001),2影响者5.6分钟(P = .002)。
临床怎么用
- 采用5影响者流程可减少医师手动靶区修正和审核时间,支持技师主导的在线自适应放疗流程。
局限性
- 研究仅纳入前列腺癌患者,需在其他癌种中进一步验证并关注临床终点。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To evaluate the impact of an optimized online adaptive radiation therapy workflow on physician involvement. METHODS AND MATERIALS: Data from a prospective phase 2 trial involving 34 prostate cancer patients treated with cone beam computed tomography (CBCT)-based online adaptive radiation therapy (62 Gy in 20 fractions) were analyzed. Manual interventions were required for 2 steps in the workflow: radiation therapy technologist review and adjustment of automatically segmented organs, guiding target segmentation, so-called "influencer," while physicians reviewed and refined the targets. Three different workflows were compared: 2-influencer (rectum and bladder), 3-influencer (+prostate), and 5-influencer (+seminal vesicles and bowel). Time for workflow steps, extent of manual corrections, and target volume changes were compared. RESULTS: A total of 613 fractions were analyzed. The 5-influencer workflow reduced manual target corrections to 11% of fractions compared with 51% for the 3-influencer workflow and 61% for the 2-influencer workflow (P < .001). Median session duration across workflows was 24.0 minutes (IQR, 22.0-28.0). Median target review times were shortest with the 5-influencer workflow at 2.5 minutes compared with 5.0 minutes for the 3-influencer workflow (P < .001) and 5.6 minutes for the 2-influencer workflow (P = .002). Most patients (84%) found the treatment time well tolerable. CONCLUSIONS: This study of prostate cancer patients suggests that optimized workflow reduces the need for physician involvement in online CBCT guided adaptive radiation therapy. Optimized workflows may facilitate a more radiation therapy technologist-driven approach similar to standard image guided radiation therapy. Further studies in other cancers, also focusing on clinical endpoints, are needed to further improve CBCT guided online adaptive radiation therapy.
引用
- Kalinauskaite G, Künzel LA, Kluge A, et al. Optimizing Workflow for Cone Beam Computed Tomography-Based Online Adaptive Radiation Therapy Toward Reduced Physician Involvement. Adv Radiat Oncol. 2025. PMID: 40927651. doi:10.1016/j.adro.2025.101874
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。