实时视频辅助表面引导定位在右侧局部区域乳腺癌放疗中的摆位精度与效率
结果显示两种摆位方式在锥形束CT(CBCT)配准后的床位移及淋巴结区域治疗位置精度上差异可忽略,但实时视频辅助使摆位时间平均缩短40秒,且系统误差与随机误差一致或几乎一致。
要点
- 实时视频辅助表面引导摆位不降低右侧乳腺癌摆位精度。
- 实时视频辅助使摆位时间平均缩短40秒,效率显著提升。
- 两种摆位方式的系统误差与随机误差一致或几乎一致。
核心结论
- 在右侧局部区域乳腺癌表面引导摆位中实施实时视频辅助可显著缩短摆位时间,且不损害摆位精度。
研究设计与样本
- 每次分次均采集治疗前锥形束CT(CBCT),利用CBCT配准后的床位移计算系统误差与随机误差,并比较淋巴结区域实际治疗位置与计划位置。
- 记录整个治疗流程中6个时间点以分析摆位效率。
主要发现
- 两种摆位方式在CBCT配准后床位移与淋巴结区域治疗位置精度上的差异可忽略。
- 垂直方向床位移的组均值在两种摆位方式间差异有统计学意义(P = .03)。
- 两种摆位方式的系统误差与随机误差一致或几乎一致,其他摆位精度指标均无显著差异。
- 采用实时视频辅助后摆位时间平均缩短40秒,摆位效率显著改善。
临床怎么用
- 在右侧局部区域乳腺癌表面引导摆位中可引入实时视频辅助,以缩短摆位时间而不影响摆位精度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Real-time video assistance in combination with surface guidance (SG) has been introduced in radiation therapy. In this study, we wanted to investigate the efficiency and accuracy of this new procedure for patients with right-sided locoregional breast cancer with special focus on the arm position. METHODS AND MATERIALS: Twenty-six patients were included. Each patient was positioned using SG with real-time video assistance for half of the fractions. For the other half of the fractions, patient's surface was captured (including arm position) and visually compared to the reference surface before adjusting the patient position. This process was repeated until the patient position was acceptable. Pretreatment cone beam computer tomography (CBCT) was acquired at every fraction. Couch shifts after CBCT match were used to calculate systematic and random errors. CBCTs were also used to compare the actual treatment position of the nodal areas to the planned position. To analyze setup efficiency, 6 time points during the whole treatment procedure were recorded and analyzed. RESULTS: Our results showed negligible differences in setup accuracy when comparing couch shifts after CBCT match and the treated position of the nodal area. The group mean of the vertical couch shifts was significantly different between the 2 setup procedures (P = .03). The systematic error and the random error, however, were identical or almost identical. No other metrics regarding setup accuracy were significantly different. Setup efficiency was significantly improved using SG with real-time video assistance. By implementing real-time video assistance, setup time was reduced by an average of 40 seconds. CONCLUSIONS: By implementing real-time video assistance in the setup of patients with right-sided locoregional breast cancer using SG, setup time can be significantly reduced without compromising setup accuracy.
引用
- Svestad JG, Mikalsen SG, Heydari M, et al. Setup Accuracy and Efficiency of Real-Time Video Assistance for Surface-Guided Positioning in Radiation Therapy of Right-Sided Locoregional Breast Cancer. Adv Radiat Oncol. 2025. PMID: 40757180. doi:10.1016/j.adro.2025.101829
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。