文献速递消化道肿瘤放疗放疗物理与技术

低剂量平均线性能量转移与碳离子放疗后胰腺癌局部复发相关

Low Dose-Averaged Linear Energy Transfer Contributes to Local Recurrence of Pancreatic Cancer Treated With Carbon Ion Radiation Therapy.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2025-07-16

回顾性分析2013至2021年106例不可手术胰腺癌患者,接受碳离子放疗(55.2 Gy RBE/12次)同步化疗。结果显示CTV最小LETd(Lmin)是局部复发的显著预测因子,低Lmin组2年累积局部复发率显著更高(32.4% vs 12.7%)。

要点

  • 以42.2 keV/µm为界,低Lmin组2年累积局部复发率32.4%,高Lmin组12.7%。

核心结论

  • 碳离子放疗中CTV内低剂量平均线性能量转移(LETd)与胰腺癌局部控制不佳相关。

研究设计与样本

  • 回顾性分析2013至2021年接受碳离子放疗同步化疗的不可手术胰腺癌患者106例。
  • 处方剂量为55.2 Gy(RBE),分12次给予。
  • 使用内部流程计算碳离子放疗计划的LETd,分析肿瘤LETd参数与局部复发的关系。

主要发现

  • 2年累积局部复发率为20.2%(95%CI 12.8%-28.9%)。

关键数值与推荐

  • CTV Lmin的截断值为42.2 keV/µm,由18个月时的时间依赖ROC分析确定。

临床怎么用

  • 碳离子放疗计划评估时除剂量外,应关注CTV内LETd分布,低Lmin可能提示局部复发风险较高。

局限性

  • 本研究为回顾性分析,样本来自单中心(原文未明确说明,但为回顾性设计)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To evaluate the effects of dose-averaged linear energy transfer (LETd) profiles on local control (LC) of pancreatic cancer treated with carbon ion radiation therapy (CIRT). METHODS AND MATERIALS: Data from patients with inoperable pancreatic cancer, treated with CIRT and concurrent chemotherapy between 2013 and 2021, were analyzed retrospectively. The prescribed dose was 55.2 Gy (relative biological effectiveness), administered in 12 fractions. The LETd of CIRT plans were calculated using a previously reported in-house pipeline. The association between tumor LETd profiles and local recurrence (LR) was analyzed. RESULTS: The study analyzed 106 patients. The 2-year cumulative LR rate was 20.2% (95% confidence interval [CI], 12.8%-28.9%). Analysis of LETd parameters using a Fine-Gray regression model showed that the minimum LETd (Lmin) for the clinical target volume (CTV) had a significant effect on LR (P = .023). According to the cut-off value of 42.2 keV/µm, determined by time-dependent receiver operating characteristic analysis at 18 months, patients with low CTV Lmin had a significantly greater cumulative LR rate than those with high CTV Lmin (P = .020; 2-year cumulative LR rate, 32.4% [95% CI, 16.6%-49.3%] vs 12.7% [95% CI, 5.8%-22.5%]). Cause-specific proportional hazards models identified CTV Lmin as a significant predictor of LR (hazard ratio, 0.83; [95% CI, 0.71-0.98]; P = .030). CTV Lmin showed a strong, significant negative correlation with CTV (P < .0001, r = -0.52). CONCLUSIONS: This is the largest study investigating the association between tumor LETd profiles and LC post-CIRT. The results suggest that low LETd within the CTV is associated with poor LC in patients with pancreatic cancer treated with CIRT.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Sakamoto S, Oike T, Kobayashi D, et al. Low Dose-Averaged Linear Energy Transfer Contributes to Local Recurrence of Pancreatic Cancer Treated With Carbon Ion Radiation Therapy. Int J Radiat Oncol Biol Phys. 2025. PMID: 40681056. doi:10.1016/j.ijrobp.2025.07.1406

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。