文献速递头颈部肿瘤放疗放疗物理与技术

人工智能辅助压缩感知技术加速头颈部肿瘤放疗的MRI模拟定位

Artificial Intelligence-Assisted Compressed Sensing Technique Accelerates Magnetic Resonance Imaging Simulation for Head and Neck Cancer Radiation Therapy.
PubMed 文献 · Adv Radiat Oncol · 2025-06-06

一项针对52例病理确诊头颈部肿瘤患者的研究,比较人工智能辅助压缩感知(ACS)与传统并行成像(PI)在3.0-T MRI模拟定位中的表现。结果显示ACS显著缩短采集时间(平均总采集时间从694.78秒降至378.50秒,平均降低比例45.52%),且图像质量、信噪比、对比噪声比及靶区勾画与PI相当。

要点

  • ACS较PI显著缩短MRI模拟定位采集时间,平均总时间降低45.52%。
  • ACS与PI的图像质量评分、信噪比及对比噪声比基本相当。
  • ACS与PI融合图像所得肿瘤靶区体积及Dice相似系数接近,不影响靶区勾画。

核心结论

  • 与PI相比,ACS可显著加速头颈部肿瘤放疗的MRI模拟定位,同时不损害图像质量及肿瘤靶区勾画的引导作用。

研究设计与样本

  • 研究纳入52例病理确诊的头颈部肿瘤患者,使用3.0-T MRI模拟定位系统,每例患者分别采用ACS和PI采集轴位T1加权梯度自旋回波、T2加权快速自旋回波以及增强后和增强后脂肪抑制T1加权梯度自旋回波序列。

主要发现

  • ACS的MRI模拟定位采集时间显著短于PI,无论单序列时间还是总采集时间(所有P < .05)。
  • PI的平均总采集时间为694.78 ± 16.85秒,使用ACS后为378.50 ± 10.05秒,平均降低比例45.52%。
  • ACS与PI的信噪比、对比噪声比及定性图像评分(病灶检出、病灶边缘锐利度、伪影、整体图像质量)几乎相当。
  • ACS与PI融合图像所得原发肿瘤和转移淋巴结的平均肿瘤靶区体积也相当(所有P > .05)。
  • 原发肿瘤和转移淋巴结的平均Dice相似系数值均接近1。

临床怎么用

  • 在头颈部肿瘤放疗MRI模拟定位中,可采用ACS技术替代PI以显著缩短采集时间,而不影响图像质量和靶区勾画。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To explore the potential of artificial intelligence-assisted compressed sensing (ACS) technique, when compared with that of conventional parallel imaging (PI) technique, in magnetic resonance imaging (MRI) simulation for head and neck cancer radiation therapy. METHODS AND MATERIALS: Fifty-two patients with pathologically confirmed head and neck cancer underwent MRI simulation using a 3.0-T MRI simulation system. For each patient, axial T1-weighted gradient spin echo, T2-weighted fast spin echo sequence, and postcontrast and postcontrast fat-suppressed T1-weighted gradient spin echo sequence were obtained by ACS and PI. Acquisition time, signal-to-noise ratio, contrast-to-noise ratio, and image quality of both sets of MRI simulation images were compared. Image quality analysis was scored with lesion detection, margin sharpness of lesions, artifacts, and overall image quality using the 5-point Likert scale. Moreover, tumor target volume acquired from fusion images of simulation computed tomography with simulation MRI by ACS and from fusion images by PI were compared. Dice similarity coefficient of gross tumor target between fusion images by ACS and those by PI were also measured. RESULTS: Acquisition time of MRI simulation by ACS was significantly shorter than that by PI, whether for the time of individual sequence or the total acquisition time (P < .05 for all). The mean total acquisition time by PI (694.78 ± 16.85 seconds) was significantly less after using ACS (378.50 ± 10.05 seconds), with a mean reduction ratio 45.52%. Signal-to-noise ratio, contrast-to-noise ratio values and qualitative image scores (lesion detection, margin sharpness, artifacts, and overall image quality) were almost comparable between ACS and PI. Mean tumor target volume of both primary tumors and metastatic lymph nodes acquired from fusion images by ACS were also comparable to those from fusion images by PI (P > .05 for all). Mean Dice similarity coefficient values for primary tumors and metastatic lymph nodes were both close to 1. CONCLUSIONS: Compared to PI, ACS can significantly accelerate MRI simulation for head and neck cancer radiation therapy without compromising image quality and degrading the guidance role of tumor target delineation.

来源:Adv Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Zhou SH, Lin MS, Luo Y, et al. Artificial Intelligence-Assisted Compressed Sensing Technique Accelerates Magnetic Resonance Imaging Simulation for Head and Neck Cancer Radiation Therapy. Adv Radiat Oncol. 2025. PMID: 40741320. doi:10.1016/j.adro.2025.101819

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。