头颈部癌症姑息快速自适应Quad Shot放疗(PEAQ-RT)
结果显示PEAQ-RT在87.5%(7/8)接受至少一个自适应周期的患者中可行,在86%(12/14)尝试的自适应分次中可行,中位减少2次模拟定位就诊。
要点
- PEAQ-RT在87.5%(7/8)接受自适应周期的患者中可行,在86%(12/14)尝试的自适应分次中可行。
- 自适应治疗平均总工作流时间为28分钟(范围14-38分钟)。
- PEAQ-RT中位减少2次(范围0-2)模拟定位就诊,中位节省50.8英里(范围40.6-848英里)路程和3.5小时出行时间。
核心结论
- PEAQ-RT使QS-RT得以实施,同时免除了后续周期额外的CT模拟定位预约。
主要发现
- PEAQ-RT工作流在87.5%(7/8)接受至少一个自适应周期的患者中可行,在86%(12/14)尝试的自适应分次中可行。
- 第二和第三周期自适应治疗平均总工作流时间为28分钟(范围14-38分钟)。
- 所有约束违反均通过在线自适应得到解决。
- PEAQ-RT中位减少2次(范围0-2)模拟定位就诊,中位节省50.8英里(范围40.6-848英里)路程和3.5小时出行时间每患者。
关键数值与推荐
- 可行性定义为在至少80%尝试的自适应分次中完成该快速自适应QS-RT工作流。
临床怎么用
- 对于需要多周期QS-RT的头颈部癌症患者,可采用在线自适应工作流免除后续周期CT模拟定位,减少就诊次数和出行负担。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE/OBJECTIVE: Quad shot radiotherapy (QS-RT) is integral to head and neck cancer palliative care, but multiple CT-simulations for QS-RT cycles can be burdensome for patients. We evaluated the ability of an online adaptive radiotherapy (ART) workflow (PEAQ-RT) to eliminate extra CT simulations in QS-RT and reduce treatment related burdens. MATERIALS/METHODS: Ten patients with head and neck malignancies were enrolled in this prospective study receiving QS-RT for up to three cycles, each comprising four fractions of 350 cGy delivered twice daily, with a total dose of 1400 cGy per cycle. QS-RT could be delivered up to three cycles, spaced three to four weeks apart. Patients underwent standard CT simulation, and the simulation plan served as the treatment plan for the first QS-RT cycle. For subsequent QS-RT cycles, patients proceeded directly to adaptive treatment via institutional online ART protocol. Feasibility was defined as completing this expedited adaptive QS-RT workflow in at least 80 % of attempted adapted fractions. RESULTS: Ten patients aged 56-89 were enrolled. Eight patients received a second cycle of QS-RT and four patients received a third cycle. PEAQ-RT workflow was feasible in 87.5% (7/8) of patients who received at least one adapted cycle and was feasible in 86% (12/14) of attempted adapted fractions. For the second and third cycles, average total workflow time for the adaptive treatments was 28 min (14-38). All constraint violations were resolved with the use of online adaptation. The PEAQ-RT workflow eliminated a median of 2 (range: 0-2) simulation visits with additional QS-RT cycles. This resulted in a median travel distance savings of 50.8 miles (range: 40.6-848 miles) and a median reduction of 3.5 h in travel time per patient. CONCLUSION: PEAQ-RT enabled QS-RT while eliminating the need for additional CT simulation appointments for subsequent cycles.
引用
- Liu W, Schiff JP, Hassanzadeh C, et al. Palliative expeditiously adaptive quad shot radiotherapy for head and neck cancers (PEAQ-RT). Clin Transl Radiat Oncol. 2025. PMID: 40703666. doi:10.1016/j.ctro.2025.101012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。