文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

碘-125低剂量率近距离放疗治疗局限期前列腺癌的剂量组学预测生化失败因素

Dosiomic predictors of biochemical failure in patients with localized prostate cancer treated with Iodine-125 low-dose-rate brachytherapy.
PubMed 文献 · Radiat Oncol · 2025-04-16

本研究纳入96例接受碘-125低剂量率近距离放疗的局限期前列腺癌患者(48例生化失败、48例无生化失败),从植入后1个月CT计算的剂量分布图像中提取1130个剂量组学特征,采用Boruta算法降维,通过验证队列的多因素逻辑回归(分析A)和衍生队列建模(分析B)评估预测效能。分析B中形状、直方图及全部四特征模型的AUC分别为0.81、0.77和0.86。四个显著剂量组学特征被识别,其中elongation、Maximum2DDiameterRow和wavelet-HHL_Skewness能强地区分预后良好与不良患者。

要点

  • 从1130个剂量组学特征中筛选出4个显著特征用于预测生化失败。
  • 分析B中形状特征、直方图特征及全部四特征模型的AUC分别为0.81、0.77和0.86。
  • elongation、Maximum2DDiameterRow和wavelet-HHL_Skewness三个特征强地区分预后良好与不良患者。

核心结论

  • 识别出四个显著剂量组学特征,其中三个特征能强地区分预后良好与不良患者。
  • 植入后CT及剂量分布的剂量组学特征可能作为评估低剂量率近距离放疗疗效的有效因素。

研究设计与样本

  • 2005年1月至2015年2月期间,1205例局限期前列腺癌患者接受碘-125种子植入且未联合外照射,其中选取96例(48例生化失败、48例无生化失败)纳入本研究。
  • 患者分为衍生队列和验证队列,从植入后1个月CT计算的剂量分布图像中提取1130个剂量组学特征(形状大小、直方图、纹理),并用Boruta算法降维。
  • 分析A使用验证队列数据进行多因素逻辑回归识别显著特征;分析B使用衍生队列数据生成逻辑回归模型,并在验证队列中用AUC评估预测准确性。

主要发现

  • 特征降维后,形状大小组、直方图组和纹理组分别保留2、2和4个特征。
  • 分析A的多因素逻辑回归识别出四个主导特征,形状大小组和纹理组各两个。
  • 分析B中,使用形状大小特征、直方图特征及全部四特征的逻辑回归预测模型的AUC分别为0.81、0.77和0.86。

关键数值与推荐

  • 分析B中形状大小特征模型的AUC为0.81,直方图特征模型为0.77,全部四特征模型为0.86。
  • 四个显著剂量组学特征中,elongation、Maximum2DDiameterRow和wavelet-HHL_Skewness三个特征强地区分预后良好与不良患者。

临床怎么用

  • 植入后CT及剂量分布的剂量组学特征可能作为评估前列腺癌低剂量率近距离放疗疗效的有效因素。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to identify dosiomic features that have a significant impact on biochemical failure (BCF) following low-dose rate (LDR) brachytherapy treatment using Iodine-125 seeds for prostate cancer and to provide insights into LDR brachytherapy treatment efficacy using a dosiomic approach. METHODS: Between January 2005 and February 2015, 1,205 patients with localized prostate cancer underwent Iodine-125 seed implantation without combined external irradiation. A total of 96 patients were selected for this study, including 48 with BCF and 48 without BCF. The patients were divided into two cohorts: derivation and validation. Dose distribution images (DDs) were calculated from computed tomography (CT) images taken one month after implantation. A total of 1,130 dosiomic features, including shape-and-size, histogram, and texture features, were extracted from these DDs, their wavelet-transformed images, and Laplacian-of-Gaussian (LoG)-filtered images. The features obtained were categorized into three groups: shape-and-size (S), histogram (H), and texture (T). The Boruta algorithm was used to eliminate less important features. Two analyses were performed: Analysis A performed a multivariate logistic regression analysis using data from the validation cohort to identify significant features. Analysis B generated logistic regression models using derivation cohort data. The accuracy of BCF prediction was assessed using the validation cohort, with performance measured using the area under the receiver operating characteristic curve (AUC). RESULTS: After the feature reduction process, two, two, and four features remained in the S, H, and T feature groups, respectively. In analysis A, the multivariate logistic regression identified four dominant features, two from each of the S and T groups. In analysis B, the AUC of the logistic regression prediction models using S, H, and all four features were 0.81, 0.77, and 0.86, respectively. CONCLUSIONS: Four significant dosiomic features were identified. Notably, three features-elongation, Maximum2DDiameterRow, and wavelet-HHL_Skewness-strongly distinguished patients with favorable prognoses from others. These findings suggest that dosiomic features from postimplant CT and dose distribution may serve as effective factors for evaluating LDR brachytherapy outcomes in patients with prostate cancer.

来源:Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Nakano M, Kaji S, Kawakami S, et al. Dosiomic predictors of biochemical failure in patients with localized prostate cancer treated with Iodine-125 low-dose-rate brachytherapy. Radiat Oncol. 2025. PMID: 40241205. doi:10.1186/s13014-025-02619-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。