切伦科夫成像生物形态特征验证乳腺放疗中组织形变下的患者体位

Cherenkov Imaged Bio-Morphological Features Verify Patient Positioning With Deformable Tissue Translocation in Breast Radiation Therapy.
PubMed 文献 · Adv Radiat Oncol · 2024-11-19

本研究利用切伦科夫图像的生物形态特征(如血管)进行刚性/非刚性配准,量化乳腺放疗中整体位移与局部组织形变。体模测试平均精度0.83 mm(平移达20 mm);10例全乳放疗患者分次间整体位移3.7±2.4 mm,局部形变达3.3±1.9 mm(区域形变第95百分位)。

要点

  • 体模平移达20 mm时平均精度0.83 mm。
  • 10例患者分次间整体位移3.7±2.4 mm。
  • 局部组织形变达3.3±1.9 mm(第95百分位)。

核心结论

  • 切伦科夫可视化生物形态特征结合刚性/非刚性配准可量化整体与局部体位变化,对现行常规成像未充分评估的局部形变提供量化指导具有可行性。

研究设计与样本

  • 方法学研究:在拟人胸部体模上通过已知距离平移治疗床和诱导呼吸运动测试,并应用于10例分次全乳放疗患者影像数据集。

主要发现

  • 体模平移达20 mm时平均精度0.83 mm。
  • 10例患者分次间整体位移3.7±2.4 mm。
  • 局部组织形变达3.3±1.9 mm(区域形变第95百分位)。

临床怎么用

  • 该方法可提供分次间/分次内体位量化指导,尤其针对常规成像未充分评估的局部组织形变。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Accurate patient positioning is crucial for precise radiation therapy dose delivery, as errors in positioning can profoundly influence treatment outcomes. This study introduces a novel application for loco-regional tissue deformation tracking via Cherenkov image analysis during fractionated breast cancer radiation therapy. The primary objective of this research was to develop and test an algorithmic method for Cherenkov-based position accuracy quantification, particularly for loco-regional deformations, which do not have an ideal method for quantification during radiation therapy. METHODS AND MATERIALS: Bio-morphological features in the Cherenkov images, such as vessels, were segmented. A rigid/nonrigid combined registration technique was employed to pinpoint both inter- and intrafractional positioning variations. The methodology was tested on an anthropomorphic chest phantom experiment via shifting a treatment couch with known distances and inducing respiratory motion to simulate interfraction setup uncertainties and intrafraction motions, respectively. It was then applied to a data set of fractionated whole breast radiation therapy human imaging (n = 10 patients). RESULTS: The methodology provided quantified positioning variations comprising 2 components: a global shift determined through rigid registration and a 2-dimensional variation map illustrating loco-regional tissue deformation quantified via nonrigid registration. Controlled phantom testing yielded an average accuracy of 0.83 mm for couch translations up to 20 mm in various directions. Analysis of clinical Cherenkov imaging data from 10 breast cancer patients compared with their first imaged fraction revealed an interfraction setup variation of 3.7 ± 2.4 mm in the global shift and loco-regional deformation up to 3.3 ± 1.9 mm (95th percentile of all regional deformation). CONCLUSIONS: This study introduces the use of Cherenkov visualized bio-morphological features to quantify the global and local variations in patient positioning based on rigid and nonrigid registrations. This new approach demonstrates the feasibility of providing quantitative guidance for inter/intrafraction positioning, particularly for the loco-regional deformations that have been unappreciated in current practice with conventional imaging techniques.

来源:Adv Radiat Oncol,查看原文。版权归原作者所有。