告别面罩!采用个体化背侧壳与表面引导实现精准头颈部放疗
结果显示分次内运动导致的CTV-PTV外扩为各方向1.1 mm,总CTV-PTV外扩可设为3 mm,提示该方法可在不牺牲治疗精度的前提下提升患者舒适度。
要点
- 分次内运动CTV-PTV外扩各方向均为1.1 mm,总外扩可设为3 mm。
- 3.5%分次因分次内运动超过2 mm或2°阈值需中断重新摆位。
核心结论
- 以SGRT联合背侧壳替代传统面罩,可为头颈部肿瘤患者提供更舒适的放疗体验而不牺牲治疗精度。
主要发现
- 1.1%的分次因CBCT期间或之后运动需重新摆位,4.4%的分次因体位不准确需重新摆位。
- 3.5%的分次因分次内运动超过2 mm或2°阈值(th2)而中断治疗以重新摆位。
- 基于治疗后CBCT确定的分次内运动CTV-PTV外扩各方向均为1.1 mm,总CTV-PTV外扩可设为3 mm。
关键数值与推荐
- 分次内运动阈值设为2 mm或2°(th2),超过时重新摆位。
- 分次内运动CTV-PTV外扩各方向均为1.1 mm。
- 总CTV-PTV外扩可设为3 mm。
临床怎么用
- 头颈部肿瘤放疗可采用个体化背侧壳联合SGRT进行定位与分次内运动监测,并以CBCT在线校正。
- 基于本研究所定分次内运动外扩1.1 mm,总CTV-PTV外扩可设为3 mm。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: Using surface guided radiotherapy (SGRT), head and neck (H&N) cancer patients may undergo radiotherapy without the discomfort and stress of a restricting face mask. In this study, the patient setup accuracy, number of necessary treatment interrupts, and intrafraction motion for H&N cancer patients positioned using an individual dorsal shell and monitored using SGRT was examined. MATERIAL AND METHODS: Twenty-six H&N cancer patients were positioned in a dorsal shell using SGRT. A cone-beam CT (CBCT) was used for online setup correction. SGRT was also used for intrafraction motion monitoring, and repositioning of the patient when an intrafraction motion threshold of 2 mm or 2° (th2) was exceeded. Based on post-treatment CBCT's, the intrafraction motion and resulting CTV-PTV margin were determined. RESULTS: For 1.1 % of fractions, the patient had to be repositioned because of motion during/after the CBCT, and for 4.4 % of fractions because of inaccurate patient posture. For 3.5 % of fractions, treatment had to be interrupted for repositioning because intrafraction motion exceeded th2. The CTV-PTV margin for intrafraction motion is 1.1 mm in all directions. A total CTV-PTV margin of 3 mm can be applied. CONCLUSIONS: By replacing traditional face masks with SGRT and a dorsal shell, we can offer H&N cancer patients a more comfortable radiotherapy treatment experience without sacrificing the treatment accuracy.
引用
- Essers M, Mesch L, Beugeling M, et al. Goodbye face masks! Accurate head and neck radiotherapy using individual dorsal shells and surface guidance. Radiother Oncol. 2025. PMID: 40288690. doi:10.1016/j.radonc.2025.110909
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。