文献速递头颈部肿瘤放疗放疗物理与技术

告别面罩!采用个体化背侧壳与表面引导实现精准头颈部放疗

Goodbye face masks! Accurate head and neck radiotherapy using individual dorsal shells and surface guidance.
PubMed 文献 · Radiother Oncol · 2025-04-25

结果显示分次内运动导致的CTV-PTV外扩为各方向1.1 mm,总CTV-PTV外扩可设为3 mm,提示该方法可在不牺牲治疗精度的前提下提升患者舒适度。

要点

  • 分次内运动CTV-PTV外扩各方向均为1.1 mm,总外扩可设为3 mm。
  • 3.5%分次因分次内运动超过2 mm或2°阈值需中断重新摆位。

核心结论

  • 以SGRT联合背侧壳替代传统面罩,可为头颈部肿瘤患者提供更舒适的放疗体验而不牺牲治疗精度。

主要发现

  • 1.1%的分次因CBCT期间或之后运动需重新摆位,4.4%的分次因体位不准确需重新摆位。
  • 3.5%的分次因分次内运动超过2 mm或2°阈值(th2)而中断治疗以重新摆位。
  • 基于治疗后CBCT确定的分次内运动CTV-PTV外扩各方向均为1.1 mm,总CTV-PTV外扩可设为3 mm。

关键数值与推荐

  • 分次内运动阈值设为2 mm或2°(th2),超过时重新摆位。
  • 分次内运动CTV-PTV外扩各方向均为1.1 mm。
  • 总CTV-PTV外扩可设为3 mm。

临床怎么用

  • 头颈部肿瘤放疗可采用个体化背侧壳联合SGRT进行定位与分次内运动监测,并以CBCT在线校正。
  • 基于本研究所定分次内运动外扩1.1 mm,总CTV-PTV外扩可设为3 mm。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: Using surface guided radiotherapy (SGRT), head and neck (H&N) cancer patients may undergo radiotherapy without the discomfort and stress of a restricting face mask. In this study, the patient setup accuracy, number of necessary treatment interrupts, and intrafraction motion for H&N cancer patients positioned using an individual dorsal shell and monitored using SGRT was examined. MATERIAL AND METHODS: Twenty-six H&N cancer patients were positioned in a dorsal shell using SGRT. A cone-beam CT (CBCT) was used for online setup correction. SGRT was also used for intrafraction motion monitoring, and repositioning of the patient when an intrafraction motion threshold of 2 mm or 2° (th2) was exceeded. Based on post-treatment CBCT's, the intrafraction motion and resulting CTV-PTV margin were determined. RESULTS: For 1.1 % of fractions, the patient had to be repositioned because of motion during/after the CBCT, and for 4.4 % of fractions because of inaccurate patient posture. For 3.5 % of fractions, treatment had to be interrupted for repositioning because intrafraction motion exceeded th2. The CTV-PTV margin for intrafraction motion is 1.1 mm in all directions. A total CTV-PTV margin of 3 mm can be applied. CONCLUSIONS: By replacing traditional face masks with SGRT and a dorsal shell, we can offer H&N cancer patients a more comfortable radiotherapy treatment experience without sacrificing the treatment accuracy.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Essers M, Mesch L, Beugeling M, et al. Goodbye face masks! Accurate head and neck radiotherapy using individual dorsal shells and surface guidance. Radiother Oncol. 2025. PMID: 40288690. doi:10.1016/j.radonc.2025.110909

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。