儿童型中线弥漫性高级别胶质瘤放疗中GTV增大与自适应放疗需求
本研究对20例新诊断中线弥漫性胶质瘤或儿童型中线高级别胶质瘤患者,在6周放疗疗程中于治疗前及第10、20次分次时重复MRI,发现12/20例出现GTV增大,14例需20次计划自适应;GTV增大组与无增大组至疾病进展时间无显著差异(中位8.1 vs 7.6个月,p=0.66)。
要点
- 6周放疗中60%患者出现GTV增大,70%患者需计划自适应。
- 应用1.0 cm CTV边界时,推荐进行计划自适应以确保足够放疗。
- GTV增大组与无增大组至疾病进展时间无显著差异(p=0.66)。
核心结论
- 重复MRI显示60%患者出现GTV增大,70%患者需计划自适应;应用1.0 cm CTV边界时推荐计划自适应以确保足够放疗。
研究设计与样本
- 纳入新诊断中线弥漫性胶质瘤或儿童型中线高级别胶质瘤接受6周放疗的患者,治疗前及第10、20次分次时行MRI并勾画GTV。
主要发现
- 20例可评估患者中,12/20例在rMRI10/rMRI20时观察到GTV增大,其中脑桥肿瘤6/11例、非脑桥肿瘤6/9例。
- 结合剂量学标准和视觉检查,14例患者共需20次计划自适应。
- GTV增大组中位至疾病进展时间8.1个月 vs 无增大组7.6个月(p=0.66),无显著差异;TTP范围1.6-17.6个月。
关键数值与推荐
- GTV增大定义为两次扫描间GTV增加>5%。
- 当前儿童型弥漫性高级别胶质瘤放疗protocols在GTV周围应用1.0 cm CTV边界。
- 计划自适应需求基于剂量学标准和视觉标准。
临床怎么用
- 对于接受6周放疗的儿童型中线高级别胶质瘤患者,重复MRI可检出GTV增大并在应用1.0 cm CTV边界时支持计划自适应。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Current pediatric-type diffuse high-grade glioma radiotherapy protocols apply a 1.0 cm clinical target volume (CTV) margin around the gross tumor volume (GTV). However, in adults with glioblastoma, large variations in GTV are observed during radiotherapy. The study aimed to map the GTV variation during a 6-week course of radiotherapy using repeated MR-imaging and to evaluate the need for plan adaptation. Also, the relation between GTV increase and time to disease progression (TTP) was assessed. MATERIAL AND METHODS: Patients with newly diagnosed diffuse midline glioma or diffuse pediatric-type high-grade glioma of the midline structures undergoing a 6-week radiotherapy course, were eligible for inclusion. MRI scans were performed in the pre-treatment phase (MRI0), and at fraction 10 + 20 (rMRI10/rMRI20). On all scans, GTV was delineated. An increase was defined as a >5 % increase of GTV between scans. The need for treatment plan adaptation was based on dosimetric and visual criteria. GTV increase was compared to TTP. RESULTS: Twenty patients were eligible. In 12/20 patients, a GTV increase was observed at rMR10/rMR20, more specifically in 6/11 pontine and 6/9 non-pontine tumors. Combining dosimetric criteria and visual inspection, 20 plan adaptations in 14 patients were required. The TTP (range: 1.6-17.6 months) was not significantly different between the group with (median 8.1 months) versus without a GTV increase (median 7.6 months; p = 0.66). CONCLUSION: Repeated imaging demonstrated a GTV increase in 60 % of patients and plan adaptation in 70 %. When applying CTV margins of 1.0 cm, plan adaptation is recommended to ensure adequate radiotherapy treatment.
引用
- van Ommen F, van Genechten T, Willemsen-Bosman ME, et al. Gross tumor volume increase and need for adaptive radiotherapy in pediatric-type diffuse high-grade glioma of the midline structures. Radiother Oncol. 2025. PMID: 40174703. doi:10.1016/j.radonc.2025.110873
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。