文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

宫颈癌放疗中计划库选择变化的剂量学评估

Dosimetric evaluation of variation in Library of plans selection for cervical cancer radiotherapy.
PubMed 文献 · Radiother Oncol · 2025-03-05

回顾性分析10例宫颈癌患者,比较临床计划选择与基于CBCT上CTV最大重叠的自动计划选择对累积剂量的影响。两种计划库选择方法间无显著剂量差异;但默认非计划库方案较临床选择降低靶区覆盖(99% vs 100%)并增加直肠V40Gy(55% vs 44%)。计划库对选择变化稳健,在靶区覆盖和OAR保护上优于非计划库方法。

要点

  • 计划库不同选择方法间累积剂量无显著差异。
  • 默认非计划库方案较临床选择靶区覆盖99% vs 100%。
  • 默认非计划库方案较临床选择直肠V40Gy 55% vs 44%。

核心结论

  • 计划库对计划选择的变化稳健,在靶区覆盖和危及器官保护方面优于非计划库方法。
  • 计划库是在线自适应再计划的 safe and efficient 替代方案,尤其适用于较长分程方案。

研究设计与样本

  • 回顾性分析10例宫颈癌患者的计划选择与剂量分布。
  • 采用两种计划选择方法:临床计划选择与基于CBCT上计划库CTV与(自动)勾画CTV最大重叠的自动计划选择。
  • 将所选计划的剂量在每日CBCT上计算并累积至CT,以预定临床目标评估剂量差异。

主要发现

  • 不同计划库计划选择方法未导致显著剂量差异。
  • 默认非计划库方案较临床选择降低靶区覆盖(99% vs 100%)。
  • 默认非计划库方案较临床选择增加直肠V40Gy(55% vs 44%)。

关键数值与推荐

  • 靶区覆盖:默认非计划库方案99% vs 临床选择100%。
  • 直肠V40Gy:默认非计划库方案55% vs 临床选择44%。

临床怎么用

  • 计划库对计划选择变化稳健,可作为在线自适应再计划的 safe and efficient 替代方案,尤其适用于较长分程方案。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The aim was to determine whether differences in treatment plan selection methods from a Library-of-Plans (LoP) on cone-beam computed tomography (CBCT) leads to significant discrepancies in total accumulated dose. METHODS: Ten cervical cancer patients were retrospectively analyzed on plan selection and dose distribution. Dose accumulation was performed using two different plan selection methods. 1) The clinical plan selections (i.e. plans as selected during actual treatment) and 2) automatic plan selection, which was based on the largest overlap between LoP clinical target volume (CTV) and (auto-)delineated CTV on CBCT. To evaluate the influence of daily plan selection on the treatment dose, the dose of selected plans was calculated on the daily CBCTs for all fractions and accumulated on the CT. The predefined clinical goals were used to determine if there was a relevant dose difference between the clinical LoP-selection, automatic LoP-selection, and selecting solely the default plan (i.e. full bladder plan with similar margins). RESULTS: Different methods of LoP-plan selection did not result in significant dose differences. However, the default non-LoP plan resulted in significant dose differences compared to LoP-selection methods, with a reduced target coverage (99 % vs 100 %) and higher V40Gy to the rectum (55 % vs 44 %) compared to the clinical selection, respectively. CONCLUSIONS: LoP is robust to variations in plan selection and LoP outperforms non-LoP approaches in terms of target coverage and organs-at-risk (OAR) sparing. Therefore, LoP is a safe and efficient alternative to online adaptive replanning, particularly for longer fractionation schemes.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. de Hond YJM, van Haaren PMA, Verrijssen AE, et al. Dosimetric evaluation of variation in Library of plans selection for cervical cancer radiotherapy. Radiother Oncol. 2025. PMID: 40054626. doi:10.1016/j.radonc.2025.110835

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。