多序列MRI在头颈癌深度学习合成CT生成中的评估

Assessing multiple MRI sequences in deep learning-based synthetic CT generation for MR-only radiation therapy of head and neck cancers.
PubMed 文献 · Radiother Oncol · 2025-02-08

本研究纳入26例头颈癌患者,采集12个MR序列(T1平扫、T1增强、T2各含4幅Dixon图像),训练14个U-Net深度学习模型生成合成CT。结果显示使用全部MR序列的像素误差最低(MAE=80.5±9.9 HU),但通道增加会增加人工组织导致自动轮廓和剂量精度下降。T1平扫联合全部Dixon图像的多通道模型质量最佳,全局Gamma通过率为97.9%±1.7%(2%/2mm剂量标准,20%最大剂量阈值)。

要点

  • T1平扫联合全部Dixon图像的多通道模型在各项sCT质量指标中排名靠前。
  • 使用全部MR序列虽MAE最低(80.5±9.9 HU),但人工组织增加致轮廓和剂量精度下降。
  • 含T2序列的模型生成的sCT质量普遍较差。

核心结论

  • 使用T1平扫序列的全部Dixon图像作为多通道输入的深度学习网络生成的sCT最具临床可行性。
  • 作者认为所提方法可能使头颈癌的MR-only放疗计划在临床环境中得以实现。

研究设计与样本

  • 研究纳入26例头颈癌患者,采集12个MR序列(T1平扫、T1增强、T2各含4幅Dixon图像)。
  • 训练14个基于U-Net框架的独特深度学习模型,以多种MR图像为输入生成sCT。
  • 采用平均绝对误差(MAE)、Dice相似系数(DSC)及Gamma通过率比较不同多通道MR-sCT模型生成的sCT与实际CT。

主要发现

  • 使用全部可用MR序列生成的sCT像素误差最低(MAE=80.5±9.9 HU),但通道增加也增加人工组织,导致自动轮廓较差和剂量精度较低。
  • 含T2序列的模型生成的sCT质量普遍较差。
  • T1平扫联合全部Dixon图像的多通道模型在各项sCT质量测量中持续排名靠前(所有结构平均DSC=80.0%±13.6%,2%/2mm剂量标准、20%最大剂量阈值下全局Gamma通过率=97.9%±1.7%)。

关键数值与推荐

  • 最佳多通道MR-sCT模型为T1平扫联合全部Dixon图像,所有结构平均DSC=80.0%±13.6%。
  • 该模型在2%/2mm剂量标准和20%最大剂量阈值下全局Gamma通过率为97.9%±1.7%。
  • 使用全部MR序列时MAE=80.5±9.9 HU。

临床怎么用

  • 作者认为所提方法可能使头颈癌的MR-only放疗计划在临床环境中得以实现。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study investigated the effect of multiple magnetic resonance (MR) sequences on the quality of deep-learning-based synthetic computed tomography (sCT) generation in the head and neck region. MATERIALS AND METHODS: 12 MR series (T1pre-, T1post-contrast, T2 each with 4 Dixon images) were collected from 26 patients with head and neck cancers. 14 unique deep-learning models using the U-Net framework were trained using multiple MRs as inputs to generate sCTs. Mean absolute error (MAE), Dice Similarity Coefficient (DSC), as well as Gamma pass rates were used to compare sCTs to the actual CT across the different multi-channel MR-sCT models. RESULTS: Using all available MR series yielded sCTs with the lowest pixel-wise error (MAE = 80.5 ± 9.9 HU), but increasing channels also increased artificial tissue which led to poorer auto-contouring and lower dosimetric accuracy. Models with T2 protocols generally resulted in poorer quality sCTs. Pre-contrast T1 with all Dixon images was the best multi-channel MR-sCT model, consistently ranking high for all sCT quality measurements (average DSC across all structures = 80.0 % ± 13.6 %, global Gamma Pass Rate = 97.9 % ± 1.7 % at 2 %/2mm dose criterion and 20 % of max dose threshold). CONCLUSIONS: Deep-learning networks using all Dixon images from a pre-contrast T1 sequence as multi-channel inputs produced the most clinically viable sCTs. Our proposed method may enable MR-only radiotherapy planning in a clinical setting for head and neck cancers.