基于零回波时间MRI生成头颈部放疗合成CT的前瞻性评估

Synthetic CT generation using Zero TE MR for head-and-neck radiotherapy.
PubMed 文献 · Radiother Oncol · 2025-01-29

本研究基于127例患者开发多任务2D U-net方法,从零回波时间(ZTE)MRI生成合成CT,并在17例独立测试中验证。临床计划重算显示PTV指标98.8%偏差小于2%,所有OAR指标偏差小于1 Gy。合成计划显示剂量差异随PTV位置变化而增大。

要点

  • ZTE-MRI扫描时间2分33秒(常规)或56秒(加速),合成CT与CT平均绝对误差94±11 HU。
  • 临床计划中98.8%的PTV指标偏差小于2%,所有OAR指标偏差小于1 Gy。
  • 合成计划显示剂量差异随PTV位置不同而增大,可作为临床计划的补充评估剂量精度。

核心结论

  • 基于临床计划,ZTE-MR生成的合成CT与CT在头颈部区域显示出极佳的剂量一致性。

研究设计与样本

  • 方法基于127例患者开发,并在17例独立测试中验证。
  • 合成CT由ZTE-MRI通过多任务2D U-net生成,扫描时间为2分33秒(常规)或56秒(加速)。
  • 临床治疗计划在合成CT上重算,比较合成CT与CT的HU值和剂量体积直方图指标。
  • 随后生成合成治疗计划,系统评估不同解剖区域的剂量学精度。

主要发现

  • 患者轮廓内合成CT与CT的平均绝对误差为94±11 HU。
  • 临床计划中,98.8%的PTV指标在合成CT与CT之间偏差小于2%,所有OAR指标偏差小于1 Gy。
  • 合成计划显示较大的剂量差异,取决于PTV的位置。

局限性

  • 头颈部区域因患者特定的空气、骨与软组织界面及口咽腔而仍具挑战性。
  • ZTE-MRI在头颈部的应用相对未充分探索。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: MRI-based synthetic CTs (synCTs) show promise to replace planning CT scans in various anatomical regions. However, the head-and-neck region remains challenging because of patient-specific air, bone and soft tissues interfaces and oropharynx cavities. Zero-Echo-Time (ZTE) MRI can be fast and silent, accurately discriminate bone and air, and could potentially lead to high dose calculation accuracy, but is relatively unexplored for the head-and-neck region. Here, we prospectively evaluated the dosimetric accuracy of a novel, fast ZTE sequence for synCT generation. MATERIALS AND METHODS: The method was developed based on 127 patients and validated in an independent test (n = 17). synCTs were generated using a multi-task 2D U-net from ZTE MRIs (scanning time: 2:33 min (normal scan) or 56 s (accelerated scan)). Clinical treatment plans were recalculated on the synCT. The Hounsfield Units (HU) and dose-volume-histogram metrics were compared between the synCT and CT. Subsequently, synthetic treatment plans were generated to systematically assess dosimetry accuracy in different anatomical regions using dose-volume-histogram metrics. RESULTS: The mean absolute error between the synCT and CT was 94 ± 11 HU inside the patient contour. For the clinical plans, 98.8% of PTV metrics deviated less than 2% between synCT and CT and all OAR metrics deviated less than 1 Gy. The synthetic plans showed larger dose differences depending on the location of the PTV. CONCLUSIONS: Excellent dose agreement was found based on clinical plans between the CT and a ZTE-MR-based synCT in the head-and-neck region. Synthetic plans are an important addition to clinical plans to evaluate the dosimetric accuracy of synCT scans.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Lauwers I, Capala M, Kaushik S, et al. Synthetic CT generation using Zero TE MR for head-and-neck radiotherapy. Radiother Oncol. 2025. PMID: 39889967. doi:10.1016/j.radonc.2025.110762

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。