多任务特征融合网络用于宫颈癌放疗CTV分割的开发与外部验证
本研究开发并验证了双分支端到端多任务特征融合网络MTF-Net,利用距离定位信息图增强宫颈癌放疗临床靶区(CTV)分割。数据来自三个中心,两中心用于训练与内部验证,第三中心作为独立外部测试集。MTF-Net内部测试平均Dice分数84.67%,外部测试77.51%,在Dice分数、阳性预测值和95%豪斯多夫距离等指标上优于商业分割软件(敏感性除外)。
要点
- MTF-Net内部测试平均Dice分数84.67%,外部测试77.51%。
- MTF-Net在Dice分数、阳性预测值和95%豪斯多夫距离上优于商业软件,敏感性除外。
- 研究提示MTF-Net在宫颈癌放疗计划中具有临床应用潜力。
核心结论
- 本研究提示MTF-Net优于现有最先进分割方法和商业软件,在宫颈癌放疗计划中具有临床应用潜力。
研究设计与样本
- 开发双分支端到端多任务特征融合网络MTF-Net,由共享编码器和两个并行解码器组成,分别生成距离定位信息图(Dimg)和CTV分割掩膜。
- 引入距离信息注意力融合模块,将Dimg特征整合到CTV分割过程以优化靶区勾画。
- 数据集来自三个中心,两中心数据用于模型训练和内部验证,第三中心数据作为独立数据集用于外部测试。
- 在临床环境中将MTF-Net与商业分割软件进行性能比较。
主要发现
- MTF-Net在内部测试数据集上平均Dice分数为84.67%,在外部测试数据集上为77.51%。
- 与商业软件相比,MTF-Net在Dice分数、阳性预测值和95%豪斯多夫距离等指标上表现更优,敏感性除外。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: Accurate segmentation of the clinical target volume (CTV) is essential to deliver an effective radiation dose to tumor tissues in cervical cancer radiotherapy. Also, although automated CTV segmentation can reduce oncologists' workload, challenges persist due to the microscopic spread of tumor cells undetectable in CT imaging, low-intensity contrast between organs, and inter-observer variability. This study aims to develop and validate a multi-task feature fusion network (MTF-Net) that uses distance-based information to enhance CTV segmentation accuracy. MATERIALS AND METHODS: We developed a dual-branch, end-to-end MTF-Net designed to address the challenges in cervical cancer CTV segmentation. The MTF-Net architecture consists of a shared encoder and two parallel decoders, one generating a distance location information map (Dimg) and the other producing CTV segmentation masks. To enhance segmentation accuracy, we introduced a distance information attention fusion module that integrates features from the Dimg into the CTV segmentation process, thus optimizing target delineation. The datasets for this study were from three centers. Data from two centers were used for model training and internal validation, and that of the third center was used as an independent dataset for external testing. To benchmark performance, we also compared MTF-Net to commercial segmentation software in a clinical setting. RESULTS: MTF-Net achieved an average dice score of 84.67% on internal and 77.51% on external testing datasets. Compared with commercial software, MTF-Net demonstrated superior performance across several metrics, including Dice score, positive predictive value, and 95% Hausdorff distance, with the exception of sensitivity. CONCLUSIONS: This study indicates that MTF-Net outperforms existing state-of-the-art segmentation methods and commercial software, demonstrating its potential effectiveness for clinical applications in cervical cancer radiotherapy planning.
引用
- Wu Z, Lu L, Xu C, et al. Development and external validation of a multi-task feature fusion network for CTV segmentation in cervical cancer radiotherapy. Radiother Oncol. 2024. PMID: 39733971. doi:10.1016/j.radonc.2024.110699
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。