文献速递乳腺癌放疗放疗物理与技术

每周锥形束CT引导校正对乳腺癌屏气放疗平均心脏剂量影响的前瞻性试验

Prospective Trial on the Impact of Weekly Cone Beam Computed Tomography-Guided Correction on Mean Heart Dose in Breast Cancer Breath-Hold Radiation Therapy.
PubMed 文献 · Adv Radiat Oncol · 2024-10-10

这项前瞻性单中心试验将55例乳腺癌患者按屏气方式分为主动呼吸控制(ABC)组19例、自主深吸气屏气(vDIBH)组16例和表面引导放疗(SGRT)组20例,比较每周锥形束CT(CBCT)在线校正前后平均心脏剂量(MHD)的累积与分次间变异。结果显示CBCT在线校正与vDIBH组分次间MHD变异显著降低相关(标准差差值22.6 cGy,p=.0389),ABC组亦显著降低(标准差差值9.9 cGy,p=.0262),SGRT组无显著影响(p=.2272);三组累积MHD均无变化。

要点

  • CBCT在线校正使vDIBH组分次间MHD标准差降低22.6 cGy(p=.0389)。
  • CBCT在线校正使ABC组分次间MHD标准差降低9.9 cGy(p=.0262)。
  • SGRT组分次间MHD变异未受CBCT校正显著影响(p=.2272),三组累积MHD均无变化。

核心结论

  • CBCT引导在线校正可降低ABC或vDIBH屏气放疗中MHD的分次间变异,SGRT条件下对MHD稳定性无影响。
  • 作者提出未来研究可探索SGRT中将CBCT频率降至低于每周,以减少治疗时间和CBCT相关辐射剂量。

研究设计与样本

  • 前瞻性单中心试验,按屏气方式序贯分配乳腺癌患者接受辅助放疗40至50 Gy,分15至25次。
  • 共纳入55例患者:vDIBH组16例、ABC组19例、SGRT组20例。
  • 在每周CBCT图像上于在线校正前后估算MHD,以每例患者MHD的平均值和标准差代表累积与分次间变异。

主要发现

  • CBCT引导在线校正与vDIBH组分次间MHD变异显著降低相关,标准差差值22.6 cGy,p=.0389。
  • CBCT引导在线校正与ABC组分次间MHD变异显著降低相关,标准差差值9.9 cGy,p=.0262。
  • CBCT引导在线校正对SGRT组分次间MHD变异无显著影响,p=.2272。
  • CBCT引导在线校正对全部3组的累积MHD均无影响。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Surface guided radiation therapy (SGRT) in breast cancer radiation therapy (RT) may decrease the need for image guidance such as cone beam computed tomography (CBCT). The goal of this study was to evaluate the impact of CBCT image guidance on the cumulative and interfractional variation of mean heart dose (MHD) during breath-hold RT in patients with breast cancer. We hypothesized that weekly CBCT is not necessary for SGRT-assisted breath-hold but is still needed in patients treated with voluntary deep inspiration breath-hold (vDIBH) and active breathing control (ABC) to maintain a stable MHD. METHODS AND MATERIALS: This was a prospective, single-center trial that sequentially assigned breast cancer patients to adjuvant RT 40 to 50 Gy in 15 to 25 fractions using vDIBH, ABC, or SGRT to reproduce the breath-hold. The MHD was estimated on each of the weekly CBCT images before and after online correction. The cumulative and interfractional variation of MHD, which were represented by the average and SD of MHD in each patient, were compared in the series of CBCT before and after online correction to evaluate whether online CBCT-guided correction could lead to a more reproducible MHD. RESULTS: Fifty-five patients were included (vDIBH = 16, ABC = 19, and SGRT = 20). The CBCT-guided online correction was associated with a significant decrease in the interfractional variation of MHD in vDIBH (SD difference, 22.6 cGy; p = .0389) and ABC (SD difference, 9.9 cGy; p = .0262), but not in SGRT (p = .2272). The CBCT-guided online correction had no impact on the cumulative MHD in all 3 groups. CONCLUSIONS: This study demonstrated that CBCT-guided online correction could reduce the interfractional variation of MHD in ABC or vDIBH. When SGRT was available, CBCT-guided correction had no impact on the stability of MHD across the treatment fractions. Future studies may explore whether the CBCT frequency could be reduced to less than weekly in SGRT to decrease treatment time and the radiation dose associated with CBCT.

来源:Adv Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Chan AW, Hoang A, Chen H, et al. Prospective Trial on the Impact of Weekly Cone Beam Computed Tomography-Guided Correction on Mean Heart Dose in Breast Cancer Breath-Hold Radiation Therapy. Adv Radiat Oncol. 2024. PMID: 39524526. doi:10.1016/j.adro.2024.101651

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。