文献速递头颈部肿瘤放疗放疗物理与技术

手动轮廓编辑对头颈癌在线自适应放疗计划质量的影响

Impact of Manual Contour Editing on Plan Quality for Online Adaptive Radiation Therapy for Head and Neck Cancer.
PubMed 文献 · Pract Radiat Oncol · 2024-10-05

该研究回顾性分析了44例头颈癌患者的349个自适应分次,模拟三种轮廓编辑流程:不编辑任何轮廓、仅编辑影响者OAR、编辑影响者和靶区。仅编辑影响者和靶区时,超过95.5%的自适应计划达到患者特异性剂量学目标,而仅编辑影响者时因靶区未编辑导致覆盖不足。

要点

  • 不编辑任何轮廓时所有OAR轮廓质量显著较差(平均DSC 0.85±0.17,HD95 3.10±5.80mm)。
  • 仅编辑影响者OAR时,靶区和其余OAR的医师编辑频率分别为80.8%至95.7%和2.3%(臂丛)至67.7%(口腔)。
  • 编辑影响者和靶区、省略其余OAR时,超过95.5%的自适应计划达到患者特异性剂量学目标。

核心结论

  • 基于锥形束CT的头颈癌在线自适应放疗流程中,仅编辑影响者OAR和靶区而省略其余OAR,可在不损害自适应计划质量的前提下有意义的加速流程。

研究设计与样本

  • 回顾性分析44例头颈癌患者的349个自适应分次,以医师编辑的OAR和靶区及相应在线自适应计划为金标准,模拟三种轮廓编辑流程:不编辑轮廓、仅编辑影响者、编辑影响者和靶区。

主要发现

  • 流程1(不编辑轮廓)导致所有OAR轮廓质量显著较差(平均DSC 0.85±0.17,HD95 3.10±5.80mm),因此未计算剂量学数据。
  • 流程2(仅编辑影响者)中,医师编辑靶区和其余OAR的频率分别为80.8%至95.7%和2.3%(臂丛)至67.7%(口腔),OAR几何差异较小(平均DSC>0.95,标准差≤0.09)。
  • 流程2因靶区轮廓未编辑(与真实靶区相比平均DSC 0.86-0.92,平均HD95 2.56-3.30mm),计划不充分且覆盖不足。
  • 流程3(编辑影响者和靶区,非影响者OAR未编辑)中,超过95.5%的自适应计划达到患者特异性剂量学目标。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Online adaptive radiation therapy (oART) has high resource costs especially for head and neck (H&N) cancer, which requires recontouring complex targets and numerous organs-at-risk (OARs). Adaptive radiation therapy systems provide autocontours to help. We aimed to explore the optimal level of editing automatic contours to maintain plan quality in a cone beam computed tomography-based oART system for H&N cancer. In this system, influencer OAR contours are generated and reviewed first, which then drives the autocontouring of the remaining OARs and targets. METHODS AND MATERIALS: Three-hundred-forty-nine adapted fractions of 44 patients with H&N cancer were retrospectively analyzed, with physician-edited OARs and targets. These contours and associated online-adapted plans served as the gold standard for comparison. We simulated 3 contour editing workflows: (1) no editing of contours; (2) only editing the influencers; and (3) editing the influencers and targets. The geometric difference was quantified using the Dice similarity coefficient (DSC) and Hausdorff distance (HD). The dosimetric differences in target coverage and OAR doses were calculated between the gold standard and these 3 simulated workflows. RESULTS: Workflow 1 resulted in significantly inferior contour quality for all OARs (mean DSC, 0.85 ± 0.17 and HD95, 3.10 ± 5.80mm); hence, dosimetric data was not calculated for workflow 1. In workflow 2, the frequency of physician editing targets and remaining OARs were 80.8% to 95.7% and 2.3% (brachial plexus) to 67.7% (oral cavity), respectively, where the OAR differences were geometrically minor (mean DSC >0.95 with std ≤0.09). However, because of the unedited target contours of workflow 2 (mean DSC, 0.86-0.92 and mean HD95, 2.56-3.30 mm vs the ground-truth targets), plans were inadequate with insufficient coverage. In workflow 3, when both targets and influencers were edited (noninfluencer OARs were unedited), >95.5% of the adapted plans achieved the patient-specific dosimetry goals. CONCLUSIONS: The cone beam computed tomography-based H&N oART workflow can be meaningfully accelerated by only editing the influencers and targets while omitting the remaining OARs without compromising the quality of the adaptive plans.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Wang S, Liao CY, Choi B, et al. Impact of Manual Contour Editing on Plan Quality for Online Adaptive Radiation Therapy for Head and Neck Cancer. Pract Radiat Oncol. 2024. PMID: 39374894. doi:10.1016/j.prro.2024.09.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。