文献速递中枢神经肿瘤放疗放疗物理与技术

原发脑肿瘤放疗计划中利用弥散张量成像保护记忆纤维束

Memory Tract Sparing Using Diffusion Tensor Imaging in Radiation Planning of Primary Brain Tumors.
PubMed 文献 · Pract Radiat Oncol · 2024-09-30

一项前瞻性试验纳入12例低级别胶质瘤术后或活检后患者,放疗总剂量54 Gy分30次,利用弥散张量成像勾画海马相关白质纤维束并整合入放疗计划。容积旋转调强放疗计划满足记忆纤维束剂量约束,平均平均剂量10.1 Gy;蒙特利尔认知评估评分放疗前27.1、治疗后8个月26.4(P=0.07)。作者认为该技术可实现海马及相关白质纤维束保护,初步认知数据有前景,需更大队列进一步验证。

要点

  • 12例低级别胶质瘤患者成功勾画记忆纤维束和海马,容积旋转调强放疗计划满足记忆纤维束剂量约束,平均平均剂量10.1 Gy。
  • 蒙特利尔认知评估评分放疗前27.1 vs 治疗后8个月26.4(P=0.07),剔除1例后分别为27.1 vs 26.6(P=0.13)。
  • 作者认为弥散张量成像引导的容积旋转调强放疗可实现海马及相关白质纤维束保护,初步认知数据有前景,需更大队列进一步验证。

核心结论

  • 作者认为,利用弥散张量成像检测记忆纤维束并整合入容积旋转调强放疗计划,可实现海马及相关白质纤维束保护,可能保留认知功能;初步认知数据有前景,支持需在更大队列中进一步验证。

研究设计与样本

  • 前瞻性试验,经机构审查委员会批准(SMC0307-23),纳入年龄≥18岁、原发脑肿瘤切除或活检后患者,排除跨至对侧半球的多灶性胶质瘤。
  • 放疗总剂量54 Gy分30次;行弥散张量成像标测海马相关白质纤维束,使用Eclipse治疗计划软件勾画记忆纤维束和海马并整合入放疗计划。
  • 剂量学分析比较2个带记忆纤维束约束的计划与1个不带约束的计划;主要终点为安全性和剂量学可行性。

主要发现

  • 共纳入12例低级别胶质瘤患者,记忆纤维束和海马勾画均成功。
  • 容积旋转调强放疗计划满足记忆纤维束剂量约束,平均平均剂量为10.1 Gy。
  • 蒙特利尔认知评估评分放疗前平均27.1,治疗后8个月平均26.4,P=0.07;剔除1例患者后分别为27.1和26.6,P=0.13。

局限性

  • 作者指出初步认知数据有前景,支持需在更大队列中进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Radiation therapy (RT) is a critical treatment modality for both primary and metastatic brain tumors, yet ∼30% of patients experience cognitive decline post-RT. This cognitive toxicity is linked to low radiation doses affecting the hippocampal dentate gyrus. Hippocampal avoidance-whole brain RT combined with memantine has shown promising outcomes in preserving cognitive function and quality of life in patients with brain metastases. Nowadays, it is the standard of care for those with good performance status and no hippocampal metastases. METHODS AND MATERIALS: We conducted a prospective trial approved by the institutional review board (SMC0307-23), including patients aged ≥18 years with primary brain tumors postresection or biopsy. Exclusion criteria included multifocal glioma crossing to the other hemisphere. RT was delivered to a total dose of 54 Gy in 30 fractions. Diffusion tensor imaging was performed to map hippocampal-associated white matter tracts. Using Eclipse treatment planning software, memory fiber tracts and hippocampi were contoured and integrated into RT planning. Dosimetric analyses compared 2 plans with memory fiber constraints and 1 without. The primary endpoints were safety and dosimetric feasibility. RESULTS: Twelve patients with low-grade gliomas were included, and the contouring of memory fibers and hippocampi was successful. Volumetric modulated arc therapy (VMAT) treatment plans met-dose constraints for memory fibers, with an average mean dose of 10.1 Gy. The average Montreal Cognitive Assessment score before RT was 27.1 and 26.4 at 8 months post-treatment, with a P value of .07. Excluding 1 patient, the scores were 27.1 and 26.6, respectively (P = .13). CONCLUSIONS: Magnetic resonance imaging planning using diffusion tensor imaging for memory fiber detection and incorporation into RT planning via VMAT techniques enables hippocampal and associated white fiber sparing, potentially preserving cognitive function. Preliminary cognitive data are promising, supporting the need for further validation in a larger cohort.

来源:Pract Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Haisraely O, Mayer A, Jaffe M, et al. Memory Tract Sparing Using Diffusion Tensor Imaging in Radiation Planning of Primary Brain Tumors. Pract Radiat Oncol. 2024. PMID: 39357773. doi:10.1016/j.prro.2024.08.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。