前列腺癌MRI引导自适应放疗的患者特异性自动计划方法
本研究回顾性收集40例前列腺癌患者数据,提出一种患者特异性自动计划方法:先训练群体剂量预测模型(M0),再以患者数据微调生成患者特异性模型(Mps),据其预测剂量分布优化自动计划。自动计划较手动计划提高了靶区覆盖、降低了直肠照射,并缩短了计划时间与机器跳数。
要点
- 自动计划使计划靶区覆盖提高0.61%(P=0.023),临床靶区4000覆盖提高1.60%(P<0.001)。
- 自动计划使直肠壁V2900cGy降低1.06%(P=0.004)、V1810cGy降低2.49%(P<0.001),直肠V1810cGy降低2.82%(P=0.012)。
- 自动计划计划时间减少3.92分钟(P=0.001),机器跳数减少46.48(P=0.003),出束时间减少0.26分钟(P=0.004)。
核心结论
- 所提出的患者特异性自动计划方法在前列腺癌MRI引导自适应放疗中展现出稳健的自动化水平,并能以更少时间生成高质量治疗计划。
研究设计与样本
- 回顾性收集40例前列腺癌患者数据,提出患者特异性自动计划方法并与手动计划在计划质量、效率、剂量学验证和临床评估方面进行比较。
主要发现
- 自动计划提高了靶区覆盖:计划靶区覆盖增加0.61%(P=0.023),临床靶区4000覆盖增加1.60%(P<0.001)。
- 自动计划降低了直肠照射:直肠壁V2900cGy减少1.06%(P=0.004)、V1810cGy减少2.49%(P<0.001),直肠V1810cGy减少2.82%(P=0.012)。
- 自动计划对其他危及器官的保护与手动计划相当。
- 自动计划计划时间减少3.92分钟(P=0.001),机器跳数减少46.48(P=0.003),出束时间减少0.26分钟(P=0.004)。
- 自动计划3%/2mm伽马通过率提高0.47%(P=0.014)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: Fast and automated generation of treatment plans is desirable for magnetic resonance imaging (MRI)-guided adaptive radiotherapy (MRIgART). This study proposed a novel patient-specific auto-planning method and validated its feasibility in improving the existing online planning workflow. MATERIALS AND METHODS: Data from 40 patients with prostate cancer were collected retrospectively. A patient-specific auto-planning method was proposed to generate adaptive treatment plans. First, a population dose-prediction model (M0) was trained using data from previous patients. Second, a patient-specific model (Mps) was created for each new patient by fine-tuning M0 with the patient's data. Finally, an auto plan was optimized using the parameters derived from the predicted dose distribution by Mps. The auto plans were compared with manual plans in terms of plan quality, efficiency, dosimetric verification, and clinical evaluation. RESULTS: The auto plans improved target coverage, reduced irradiation to the rectum, and provided comparable protection to other organs-at-risk. Target coverage for the planning target volume (+0.61 %, P = 0.023) and clinical target volume 4000 (+1.60 %, P < 0.001) increased. V2900cGy (-1.06 %, P = 0.004) and V1810cGy (-2.49 %, P < 0.001) to the rectal wall and V1810cGy (-2.82 %, P = 0.012) to the rectum were significantly reduced. The auto plans required less planning time (-3.92 min, P = 0.001), monitor units (-46.48, P = 0.003), and delivery time (-0.26 min, P = 0.004), and their gamma pass rates (3 %/2 mm) were higher (+0.47 %, P = 0.014). CONCLUSION: The proposed patient-specific auto-planning method demonstrated a robust level of automation and was able to generate high-quality treatment plans in less time for MRIgART in prostate cancer.
引用
- Liu X, Chen X, Chen D, et al. A patient-specific auto-planning method for MRI-guided adaptive radiotherapy in prostate cancer. Radiother Oncol. 2024. PMID: 39245067. doi:10.1016/j.radonc.2024.110525
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。