前瞻性随机试验比较乳腺癌放疗中两种深吸气屏气管理设备:BRAVEHeart试验结果

Prospective Randomized Trial Comparing 2 Devices for Deep Inspiration Breath Hold Management in Breast Radiation Therapy: Results of the BRAVEHeart Trial.
PubMed 文献 · Adv Radiat Oncol · 2024-07-15

BRAVEHeart试验将左侧乳腺癌患者随机分配至新型胸表面追踪系统或腹部挡块追踪系统进行深吸气屏气生物反馈,回顾分析239,296张电影电子射野影像以量化治疗精度。26例可分析患者中,两臂治疗精度无差异;胸表面与内胸壁运动的中位相关性为0.69,腹部挡块为0.17。结论未发现胸表面追踪设备在治疗精度、满意度或预约时长上优于腹部挡块系统。

要点

  • 两臂之间治疗精度无差异。
  • 胸表面与内胸壁运动的中位相关性为0.69,腹部挡块为0.17。
  • 患者认为两种系统的视觉反馈均易于遵循,两臂预约时长无差异。

核心结论

  • 未发现统计证据表明新型胸表面追踪设备在治疗精度、满意度或预约时长上优于腹部挡块系统。
  • 在深吸气屏气期间,内胸壁运动与胸表面运动的中位每次屏气相关性高于腹部挡块与胸表面的中位相关性。

研究设计与样本

  • 前瞻性随机试验将左侧乳腺癌患者随机分配至新型胸表面追踪系统或腹部挡块系统进行深吸气屏气主动管理并给予视觉反馈。
  • 两臂均被动监测未分配的系统,回顾分析239,296张电影电子射野影像以提取胸壁位置。
  • 26例参与者的数据可进行分析。

主要发现

  • 两臂之间治疗精度无差异。
  • 在所有患者和分次中,内胸壁运动与外替代物之间的中位相关性为胸表面0.69、腹部挡块0.17。
  • 患者认为两种系统的视觉反馈均易于遵循。
  • 两臂之间预约时长无差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The Breast Radiotherapy Audio Visual Enhancement for sparing the Heart (BRAVEHeart) trial prospectively randomized patients with left-sided breast cancer to 1 of 2 deep inspiration breath hold biofeedback devices: a novel chest surface tracking system and an abdominal block tracking system. The primary hypothesis was that the accuracy of chest tracking would be higher than that of abdominal tracking as the chest is a more direct surrogate of the breast target. METHODS AND MATERIALS: Patients with left-sided breast cancer were treated in deep inspiration breath hold with intensity modulated radiation therapy delivery. Patients were randomized to either the novel chest surface system or abdominal block system for active management of breath hold with visual feedback. On both trial arms, the unallocated system was monitored passively. A total of 239,296 cine electronic portal imaging device images were analyzed retrospectively to extract the chest wall position. Treatment accuracy was quantified as the deviation of the internal chest wall during treatment relative to the planned position from the digitally reconstructed radiograph. The correlation between motion of the external surrogate and internal chest wall was calculated per-breath hold. Ease of use was assessed with questionnaires for both radiation therapists and patients and appointment length recorded. RESULTS: Data from 26 participants were available for analysis. No difference was found in delivered treatment accuracy between arms. Across all patients and fractions, the median correlation between internal chest wall movement and external surrogate was 0.69 for the chest surface and 0.17 for the abdominal block. Patients found it easy to follow visual feedback from both systems. No difference was found in appointment length between arms. CONCLUSIONS: No statistical evidence was found for superior treatment accuracy, satisfaction, or appointment length for the novel chest surface tracking device compared with the abdominal block system. During deep inspiration breath hold, the median per-breath hold correlation of internal chest wall movement to the motion of the chest surface was higher than the median correlation of the abdominal block to the chest surface.