文献速递头颈部肿瘤放疗放疗物理与技术

鼻腔鼻窦黏膜黑色素瘤碳离子放疗的临床靶区设计与剂量

Clinical target volume design and dose in carbon-ion radiation therapy for sinonasal mucosal melanoma.
PubMed 文献 · Radiother Oncol · 2024-08-30

回顾135例接受碳离子放疗的鼻腔鼻窦黏膜黑色素瘤患者,处方剂量为57.6或64 Gy分16次,评估临床靶区设计与局部复发模式的关系。扩大临床靶区可显著降低模式II局部复发风险,且此类复发未出现在接受>40 Gy的区域;推荐在至少40 Gy的扩大临床靶区后使用较小靶区以减少不良事件,64 Gy技术显示良好结局。

要点

  • 扩大临床靶区显著降低模式II局部复发风险,此类复发未见于>40 Gy区域。
  • 推荐在至少40 Gy的扩大临床靶区后使用较小靶区以减少不良事件。
  • 57.6 Gy对大肿瘤局部控制不充分;64 Gy最新技术显示良好结局。

核心结论

  • 鼻腔鼻窦黏膜黑色素瘤碳离子放疗采用扩大临床靶区是合适的,即使对小肿瘤亦然。
  • 推荐在至少40 Gy的扩大临床靶区后使用较小靶区以减少不良事件。
  • 大肿瘤的处方剂量57.6 Gy对局部控制不充分。
  • 原发肿瘤的最佳剂量尚不明确,但采用64 Gy的最新技技术显示良好结局。

研究设计与样本

  • 回顾性分析135例接受碳离子放疗的鼻腔鼻窦黏膜黑色素瘤患者。
  • 相对生物效应加权剂量为57.6或64 Gy分16次。
  • 临床靶区分为小临床靶区(包括大体肿瘤及可见黑色素病变并一定边界)和扩大临床靶区(包括肿瘤部位及邻近解剖结构)。

主要发现

  • 5年局部复发率为35.3%。
  • 处方剂量不是模式I局部复发的显著危险因素,但57.6 Gy对大肿瘤局部控制不充分。
  • 使用扩大临床靶区与模式II局部复发风险降低显著相关,且此类复发未发生在接受>40 Gy的区域。
  • 5年模式III局部复发率为6.4%。

关键数值与推荐

  • 局部复发模式I定义为大体肿瘤区域复发,模式II定义为可见黑色素病变和亚临床区域复发(若采用扩大临床靶区则可被覆盖),模式III定义为扩大临床靶区外复发。
  • 相对生物效应加权剂量为57.6或64 Gy分16次。

临床怎么用

  • 作者推荐在至少40 Gy的扩大临床靶区后使用较小靶区以减少不良事件。
  • 作者认为采用扩大临床靶区用于鼻腔鼻窦黏膜黑色素瘤碳离子放疗是合适的,即使对小肿瘤亦然。
  • 作者指出原发肿瘤的最佳剂量尚不明确,但采用64 Gy的最新技技术显示良好结局。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND AND PURPOSE: No guidelines exist for the clinical target volume (CTV) and radiotherapy dose in sinonasal mucosal melanoma (SNMM). Thus, we aimed to determine the carbon-ion radiotherapy (CIRT) CTV and dose for SNMM. MATERIALS AND METHODS: In total, 135 patients with SNMM who received CIRT were reviewed. The relative biological effectiveness-weighted dose was 57.6 or 64 Gy in 16 fractions. CTV was classified into small CTV, which included the gross tumor and visible melanosis with a certain margin, and extended CTV, which included the tumor site and adjacent anatomical structures. Local recurrence (LR) patterns were pattern I, II, and III, defined as recurrence over the gross tumor, visible melanosis and subclinical area, which would be covered if extended CTV was applied, and outside the extended CTV, respectively. RESULTS: The 5-year LR rate was 35.3 %. The prescribed dose was not a significant risk factor for pattern I LR; however, 57.6 Gy for a large tumor was insufficient for local control. Using an extended CTV was significantly associated with a lower risk of pattern II LR, and these recurrences did not occur in regions that received > 40 Gy. The 5-year pattern III LR rate was 6.4 %. CONCLUSION: Utilizing an extended CTV in CIRT for SNMM is appropriate even for small tumors. Using a smaller CTV after an extended CTV of at least 40 Gy is recommended to reduce adverse events. Although the optimal dose for gross tumors remains unclear, the latest technology with 64 Gy showed good outcomes.

来源:Radiother Oncol,查看原文。版权归原作者所有。

引用

  1. Yang WC, Koto M, Ikawa H, et al. Clinical target volume design and dose in carbon-ion radiation therapy for sinonasal mucosal melanoma. Radiother Oncol. 2024. PMID: 39216826. doi:10.1016/j.radonc.2024.110511

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。