文献速递泌尿生殖与妇科肿瘤放疗放疗物理与技术

宫颈癌实施每日计划:靶区体积生成方法的比较

Implementing Plan of the Day for Cervical Cancer: A Comparison of Target Volume Generation Methods.
PubMed 文献 · Adv Radiat Oncol · 2024-07-01

本研究对40例宫颈癌患者采用膀胱充盈变化的3次计划扫描和每日锥形束CT,比较文献中30种靶区生成方法。基于膀胱体积建模外推的2计划库平均覆盖98%、平均PTV体积1419 cm³,3计划库(10 mm外扩)平均覆盖96%、平均PTV体积1346 cm³,均以较小PTV获得良好覆盖。

要点

  • 建模外推的2计划PotD库平均覆盖98%,平均PTV体积1419 cm³。
  • 3计划库(每次计划扫描CTV加10 mm外扩)平均覆盖96%,平均PTV体积1346 cm³。
  • 最佳非自适应策略覆盖未显著优于最佳PotD策略(P = .13),但PTV更大(P = .02)。

核心结论

  • 研究识别出建模的2计划方法和简单的3计划方法,两者与非自适应策略相比均以较小PTV提供良好覆盖。

研究设计与样本

  • 40例宫颈癌患者各有3次膀胱充盈变化的计划扫描,放疗期间每日行锥形束CT,选取5至11次锥形束CT代表分次间运动。
  • 临床靶区(CTV)和危及器官按EMBRACE-II指南勾画,文献检索识别出30种自适应和非自适应PTV生成方案并应用于本组患者。
  • 对11例患者还研究了临床实施的主观编辑计划库。

主要发现

  • 11项研究在中位14例患者(范围9至23例)中评估了15种PotD策略与非自适应对照。
  • 提供全部患者100%覆盖所需的固定等向外扩为44 mm,平均PTV体积为3316 cm³。
  • 覆盖最佳的PotD策略为基于膀胱体积建模外推形成的2计划库,平均覆盖98%,平均PTV体积1419 cm³。
  • 由每次计划扫描CTV加10 mm外扩组成的3计划库平均覆盖96%,平均PTV体积1346 cm³。
  • 临床实施的主观外推方案在11例亚组中平均覆盖100%,PTV体积1282 cm³。

关键数值与推荐

  • 最佳非自适应策略提供的覆盖未统计学显著优于最佳PotD策略(P = .13),但PTV更大(P = .02)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Owing to substantial interfraction motion in cervical cancer, plan-of-the-day (PotD) adaptive radiation therapy may be of benefit to patients. Implementation is limited by uncertainty over how to generate the planning target volumes (PTVs). We compared published methods on our own patients. METHODS AND MATERIALS: Forty patients each had 3 planning scans with variable bladder filling and daily cone beam computed tomographies (cone beam CTs) during radiation therapy; 5 to 11 cone beam CTs were selected to represent interfraction motion. Clinical target volumes (CTVs) and organs at risk were contoured following EMBRACE-II guidelines. A literature search identified 30 adaptive and nonadaptive solutions to PTV generation, which we applied to our patients. PTV sizes and mean coverage of the daily CTV were determined. For 11 patients, the clinically implemented, subjectively edited plan library was also investigated. RESULTS: Eleven studies assessed 15 PotD strategies against nonadaptive comparators on a median of 14 patients (range, 9-23). Some PotD approaches applied margin recipes to the CTV on each planning scan, some modeled the CTV against bladder volume, and others applied incremental isotropic margins to the CTV with a single planning scan. Generally, coverage improved as PTV size increased. The fixed isotropic margin required to provide 100% coverage of all patients was 44 mm, with a mean PTV size of 3316 cm3. The PotD strategy with the best coverage was a 2-plan library formed by modeling the CTV against bladder volume with extrapolation; it provided 98% mean coverage with 1419-cm3 mean PTV size. A 3-plan library consisting of the CTV on each planning scan with 10-mm margin provided 96% mean coverage with 1346-cm3 mean PTV size. The clinically implemented solution that employed subjective extrapolation had mean 100% coverage and 1282-cm3 PTV size on the 11-patient subset. Coverage provided by the best nonadaptive strategies was not statistically superior to the best PotD strategy (P = .13), but PTVs were larger (P = .02). CONCLUSIONS: We identified a modeled 2-plan method and a simple 3-plan method, both of which provided excellent coverage with small PTVs compared with nonadaptive strategies.

来源:Adv Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Wang L, Mohajer J, McNair H, et al. Implementing Plan of the Day for Cervical Cancer: A Comparison of Target Volume Generation Methods. Adv Radiat Oncol. 2024. PMID: 39155886. doi:10.1016/j.adro.2024.101560

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。