基于CT不同感兴趣区影像组学分析预测局部晚期非小细胞肺癌放化疗后急性放射性肺炎
回顾性纳入2家机构236例局部晚期非小细胞肺癌患者(59例RP≥2),从全肺、肺V20及肺减PTV的V30三个感兴趣区提取影像组学特征建模。基于V30 Lung-PTV区域的LightGBM影像组学模型预测效能最佳,主队列AUC 0.930,外部验证队列AUC 0.887,优于传统剂量学模型。
要点
- 基于V30 Lung-PTV区域的影像组学模型在主队列AUC为0.930,外部验证队列AUC为0.887。
- 剂量学模型主队列AUC为0.798,外部验证队列AUC为0.793。
- 影像组学联合剂量学模型主队列AUC为0.940,外部验证队列AUC为0.951。
核心结论
- 影像组学模型较传统剂量学模型能更有效地预测急性放射性肺炎。
- 基于V30 Lung-PTV区域的影像组学模型较其他区域可获得更高的准确性。
研究设计与样本
- 回顾性研究,纳入2家机构236例非小细胞肺癌患者,其中59例发生RP≥2。
- 患者分为主队列182例(46例RP≥2)和外部验证队列54例(13例RP≥2)。
- 从全肺、肺V20的DVH区域及肺减PTV的V30的DVH区域三个感兴趣区各提取107个影像组学特征。
- 采用U检验、相关系数和LASSO回归进行特征筛选,基于不同分类算法建立6个模型以选出最佳影像组学模型(R模型)。
- 另建立剂量学模型(D模型),并与最佳R模型联合构建混合模型(R+D模型)。
主要发现
- 三个感兴趣区中,基于V30 Lung-PTV区域、由LightGBM算法构建的R模型判别能力最强,AUC为0.930(95%CI:0.829-0.941)。
- 主队列中D模型、R模型和R+D模型的AUC分别为0.798(95%CI:0.732-0.865)、0.930(95%CI:0.829-0.941)和0.940(95%CI:0.906-0.974)。
- 外部验证队列中D模型、R模型和R+D模型的AUC分别为0.793(95%CI:0.637-0.949)、0.887(95%CI:0.810-0.993)和0.951(95%CI:0.891-1.000)。
- 决策曲线分析显示R+D模型通过评估临床实用性可使患者获益。
关键数值与推荐
- R模型基于V30 Lung-PTV区域构建,主队列AUC为0.930(95%CI:0.829-0.941),外部验证队列AUC为0.887(95%CI:0.810-0.993)。
- D模型主队列AUC为0.798(95%CI:0.732-0.865),外部验证队列AUC为0.793(95%CI:0.637-0.949)。
- R+D模型主队列AUC为0.940(95%CI:0.906-0.974),外部验证队列AUC为0.951(95%CI:0.891-1.000)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To establish a radiomics model using radiomics features from different region of interests (ROI) based on dosimetry-related regions in enhanced computed tomography (CT) simulated images to predict radiation pneumonitis (RP) in patients with non-small cell lung cancer (NSCLC). METHODS: Our retrospective study was conducted based on a cohort of 236 NSCLC patients (59 of them with RP≥2) who were treated in 2 institutions and divided into the primary cohort (n = 182,46 of them with RP≥2) and external validation cohort (n = 54,13 of them with RP≥2). Radiomic features extracted from three ROIs were defined as the whole lung (WL), the dose volume histogram (DVH) of the lung V20 (V20_Lung) and the DVH of the V30 of lung minus the planning target volume (PTV) (V30 Lung-PTV). A total of 107 radiomics features were extracted from each ROIs. The U test, correlation coefficient and least absolute shrinkage and selection operator (LASSO) were performed for features selection. Six models based on different classification algorithms were developed to select the best radiomics model (R model).In addition, we built a dosimetry model then combined it with the best R model to create a mixed model (R+D model) The receiver operating characteristic (ROC) curve was delineated to assess the predictive efficacy of the models. Decision curve analysis could benefit from the model proposals through the assessment of clinical utility. RESULTS: Among the three ROIs, the best R model constructed from the LightGBM algorithm demonstrated the strongest discriminative ability in the ROI of V30 Lung-PTV. The corresponding area under the curve (AUC) value was 0.930 (95 % confidence interval (CI): 0.829-0.941). The D model, R model and R+D model achieved AUC values of 0.798 (95 %CI: 0.732-0.865), 0.930 (95 %CI: 0.829-0.941) and 0.940 (95 %CI: 0.906-0.974) in primary cohort, and in external validation cohort, the AUC values were 0.793 (95 %CI:0.637-0.949), 0.887 (95 %CI:0.810-0.993), 0.951 (95CI%:0.891-1.000). Decision curve demonstrate that R+D model could benefit for patients through the assessment of clinical utility. CONCLUSION: The radiomics model was able to predict the acute RP more effectively in comparison with the traditional dosimetry model. Especially the radiomics model based on the V30 Lung-PTV region was able to achieve a higher accuracy when compared to the other regions.
引用
- Hou L, Chen K, Zhou C, et al. CT-based different regions of interest radiomics analysis for acute radiation pneumonitis in patients with locally advanced NSCLC after chemoradiotherapy. Clin Transl Radiat Oncol. 2024. PMID: 39189001. doi:10.1016/j.ctro.2024.100828
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。