子宫运动分析用于放疗计划优化:机载混合磁共振成像的创新贡献
本研究对15例局部晚期宫颈癌患者在磁共振引导放疗期间进行每日MRI扫描分析宫颈子宫结构变化,发现宫颈子宫结构中位体积缩小31%,并确定治疗全程及第14次分次后所需的不对称计划靶区外放边界。
要点
- 15例局部晚期宫颈癌患者共372次MRI扫描显示宫颈子宫结构中位体积缩小31%。
- 治疗全程所需计划靶区外放边界为头侧2cm、尾侧0.5cm、后侧1.5cm、前侧2cm、两侧各1.5cm。
- 第14次分次后较小边界(头侧0.7cm、尾侧0.5cm、后侧1.3cm、前侧1.3cm、两侧各1.3cm)已足够。
核心结论
- 宫颈子宫结构活动度在放疗期间发生变化,提示第三周后可缩小计划靶区外放边界。
研究设计与样本
- 研究纳入15例接受同步放化疗的局部晚期宫颈癌患者,采用MRIdian系统按同步整合推量方案放疗。
- 处方剂量为PTV1 55-50.6 Gy分22次、PTV2 45-39.6 Gy分25次。
- 基于模拟MRI在宫颈子宫结构上分别外放0.5、0.7、1、1.3、1.5和2 cm生成6个计划靶区。
- 以95%患者整个治疗期间95%宫颈子宫结构被覆盖为标准确定足够外放边界。
主要发现
- 15例患者共372次MRI扫描显示宫颈子宫结构中位体积缩小31%。
关键数值与推荐
- 治疗全程计划靶区最佳不对称外放边界为头侧2 cm、尾侧0.5 cm、后侧1.5 cm、前侧2 cm、两侧各1.5 cm。
- 第14次分次后较小边界(头侧0.7 cm、尾侧0.5 cm、后侧1.3 cm、前侧1.3 cm、两侧各1.3 cm)已足够。
临床怎么用
- 作者认为采用混合MRI引导系统的定制MRgRT工作流程、缩小PTV外放边界的简化IGRT很重要。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Organ motion (OM) and volumetric changes pose challenges in radiotherapy (RT) for locally advanced cervical cancer (LACC). Magnetic Resonance-guided Radiotherapy (MRgRT) combines improved MRI contrast with adaptive RT plans for daily anatomical changes. Our goal was to analyze cervico-uterine structure (CUS) changes during RT to develop strategies for managing OM. MATERIALS AND METHODS: LACC patients received chemoradiation by MRIdian system with a simultaneous integrated boost (SIB) protocol. Prescription doses of 55-50.6 Gy at PTV1 and 45-39.6 Gy at PTV2 were given in 22 and 25 fractions. Daily MRI scans were co-registered with planning scans and CUS changes were assessed.Six PTVs were created by adding 0.5, 0.7, 1, 1.3, 1.5, and 2 cm margins to the CUS, based on the simulation MRI. Adequate margins were determined to include 95 % of the CUSs throughout the entire treatment in 95 % of patients. RESULTS: Analysis of 15 LACC patients and 372 MR scans showed a 31 % median CUS volume decrease. Asymmetric margins of 2 cm cranially, 0.5 cm caudally, 1.5 cm posteriorly, 2 cm anteriorly, and 1.5 cm on both sides were optimal for PTV, adapting to CUS variations. Post-14th fraction, smaller margins of 0.7 cm cranially, 0.5 cm caudally, 1.3 cm posteriorly, 1.3 cm anteriorly, and 1.3 cm on both sides sufficed. CONCLUSION: CUS mobility varies during RT, suggesting reduced PTV margins after the third week. MRgRT with adaptive strategies optimizes dose delivery, emphasizing the importance of streamlined IGRT with reduced PTV margins using a tailored MRgRT workflow with hybrid MRI-guided systems.
引用
- Romano A, Votta C, Nardini M, et al. Uterus motion analysis for radiotherapy planning optimization. The innovative contribution of on-board hybrid MR imaging. Clin Transl Radiat Oncol. 2024. PMID: 39005509. doi:10.1016/j.ctro.2024.100808
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。