文献速递乳腺癌放疗放疗物理与技术

使用自动勾画系统与RapidPlan模型快速筛选适合深吸气屏气的左乳腺癌辅助调强放疗患者

Rapid Selection of Patients Suitable for Deep Inspiration Breath-Hold Using an Automatic Delineating System and RapidPlan Model in Patients With Left Breast Cancer Undergoing Adjuvant Radiation Therapy With IMRT.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2024-06-27

本研究纳入136例左乳腺癌自由呼吸计划(手动勾画-手动计划),其中104例用于训练RapidPlan模型,32例由软件自动勾画后经RapidPlan生成计划(自动勾画-RapidPlan);另纳入40例使用深吸气屏气(DIBH)的患者分析心脏获益差异。结果显示两种计划多数剂量学参数无显著差异,RapidPlan模型可快速准确预测自由呼吸下心脏剂量,自由呼吸平均心脏剂量(FB-MHD)≥4 Gy可作为筛选适合DIBH患者的剂量阈值。

要点

  • 自动勾画联合RapidPlan模型可快速准确预测左乳腺癌自由呼吸下的心脏剂量。
  • 保乳术后患者两种计划心脏剂量强相关(0.80≤r≤0.88,P<.05),改良根治术后中度相关(0.46≤r≤0.58,P<.05)。
  • FB-MHD≥4 Gy的患者从DIBH获得的心脏获益显著大于FB-MHD<4 Gy者。

核心结论

  • 自动勾画联合RapidPlan模型可快速、准确地预测左乳腺癌患者自由呼吸下的心脏剂量。
  • FB-MHD≥4 Gy可作为筛选适合DIBH患者的剂量阈值。

研究设计与样本

  • 纳入136例左乳腺癌临床批准的自由呼吸计划,定义为手动勾画-手动计划(MD-MP)。
  • 136例中104例用于RapidPlan模型训练;32例由软件自动勾画后经RapidPlan生成计划,定义为自动勾画-RapidPlan(AD-RP)。
  • 另纳入40例使用DIBH的患者,分析DIBH心脏获益差异。

主要发现

  • 针对保乳术后和改良根治术后分别建立两个RapidPlan模型。
  • MD-MP与AD-RP多数剂量学参数无显著差异。
  • 保乳术后患者两种计划心脏剂量强相关(0.80≤r≤0.88,P<.05);改良根治术后中度相关(0.46≤r≤0.58,P<.05)。
  • RapidPlan模型对上述两种手术后患者预测平均心脏剂量(MHD)的误差分别在±59.67 cGy和±63.32 cGy以内。
  • FB-MHD≥4 Gy患者从DIBH获得的心脏获益显著大于FB-MHD<4 Gy患者。

关键数值与推荐

  • FB-MHD≥4 Gy可作为筛选适合DIBH患者的剂量阈值。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study aimed to determine whether radiation therapy plans created using an automatic delineating system and a RapidPlan (RP) module could rapidly and accurately predict heart doses and benefit from deep inspiratory breath-hold (DIBH) in patients with left breast cancer. METHODS AND MATERIALS: One hundred thirty-six clinically approved free breathing (FB) plans for patients with left breast cancer were included, defined as manual delineation-manual plan (MD-MP). A total of 104 of 136 plans were selected for RP model training. A total of 32 of 136 patients were automatically delineated by software, after which the RP generated plans, defined as automatic delineation-RapidPlan (AD-RP). In addition, 40 patients who used DIBH were included to analyze differences in heart benefits from DIBH. RESULTS: Two RP models were established for post-breast-conserving surgery (BCS) and post-modified radical mastectomy. There were no significant differences in most of the dosimetric parameters between the MD-MP and AD-RP. The heart doses of the 2 plans were strongly correlated in patients after BCS (0.80 ≤ r ≤ 0.88, P < .05) and moderately correlated in patients after postmodified radical mastectomy (0.46 ≤ r ≤ 0.58, P <.05). The RP model predicted the mean heart dose (MHD) within ± 59.67 cGy and ± 63.32 cGy for patients who underwent the 2 surgeries described above. The heart benefits from DIBH were significantly greater in patients with FB-MHD ≥ 4 Gy than in those with FB-MHD < 4 Gy. CONCLUSIONS: The combined automatic delineation RP model allows for the rapid and accurate prediction of heart dose under FB in patients with left breast cancer. FB-MHD ≥ 4 Gy can be used as a dose threshold to select patients suitable for DIBH.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Zhou YY, Li YN, Xu JF, et al. Rapid Selection of Patients Suitable for Deep Inspiration Breath-Hold Using an Automatic Delineating System and RapidPlan Model in Patients With Left Breast Cancer Undergoing Adjuvant Radiation Therapy With IMRT. Int J Radiat Oncol Biol Phys. 2024. PMID: 38942395. doi:10.1016/j.ijrobp.2024.06.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。