文献速递胸部肿瘤放疗放疗物理与技术

利用双能CT碘图评估辐射剂量对肺功能的影响

Evaluation of Radiation Dose Effect on Lung Function Using Iodine Maps Derived From Dual-Energy Computed Tomography.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2024-05-03

该前瞻性研究(NCT04863027)纳入48例肺癌患者,在放疗前及放疗后6、12个月行双源CT模拟机增强双能CT,提取碘图并计算归一化功能反应(NFR),评估常规或立体定向放疗后肺灌注的纵向变化。结果显示NFR与剂量呈线性相关(P < .001),放疗后月数与NFR相关(P = .029),但NFR与肺功能检查变化不相关。

要点

  • 双能CT碘图可用于放疗后肺功能的详细解剖学评估,包括潜在的亚临床变化。
  • NFR与剂量在立体定向体部放疗和常规分割调强放疗两组中均呈线性相关(P < .001)。
  • NFR与肺功能检查变化不相关。

核心结论

  • 双能CT衍生碘图是详细解剖学评估辐射对肺功能影响的有前景的方法,包括潜在的亚临床变化。

研究设计与样本

  • 前瞻性研究(试验标识NCT04863027),纳入48例肺癌患者,放疗前及放疗后6、12个月行双源CT模拟机增强双能CT并提取碘图,同时行肺功能检查。
  • 48例中21例(44%)接受立体定向体部放疗,27例(56%)接受常规分割调强放疗;最终31例纳入数据分析。

主要发现

  • NFR与剂量在两组中均呈线性相关(P < .001)。
  • 放疗后月数与NFR相关(P = .029),但立体定向体部放疗亚组未观察到该相关性。
  • NFR与肺功能检查变化不相关。

关键数值与推荐

  • 归一化功能反应按3个剂量范围计算:<5 Gy、5至20 Gy、>20 Gy。
  • 参考区域定义为5 Gy等剂量体积外灌注位于前10%的所有体素。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: There is interest in using dual-energy computed tomography (DECT) to evaluate organ function before and after radiation therapy (RT). The purpose of this study (trial identifier: NCT04863027) is to assess longitudinal changes in lung perfusion using iodine maps derived from DECT in patients with lung cancer treated with conventional or stereotactic RT. METHODS AND MATERIALS: For 48 prospectively enrolled patients with lung cancer, a contrast-enhanced DECT using a dual-source CT simulator was acquired pretreatment and at 6 and 12 months posttreatment. Pulmonary functions tests (PFT) were obtained at baseline and at 6 and 12 months posttreatment. Iodine maps were extracted from the DECT images using a previously described 2-material decomposition framework. Longitudinal iodine maps were normalized using a reference region defined as all voxels with perfusion in the top 10% outside of the 5 Gy isodose volume. Normalized functional responses (NFR) were calculated for 3 dose ranges: <5, 5 to 20, and >20 Gy. Mixed model analysis was used to assess the correlation between dose metrics and NFR. Pearson correlation was used to assess if NFRs were correlated with PFT changes. RESULTS: Out of the 48 patients, 21 (44%) were treated with stereotactic body RT and 27 (56%) were treated with conventionally fractionated intensity-modulated RT. Thirty-one out of these 48 patients were ultimately included in data analysis. It was found that NFR is linearly correlated with dose (P < .001) for both groups. The number of months elapsed post-RT was also found to correlate with NFR (P = .029), although this correlation was not observed for the stereotactic body RT subgroup. The NFR was not found to correlate with PFT changes. CONCLUSIONS: DECT-derived iodine maps are a promising method for detailed anatomic evaluation of radiation effect on lung function, including potentially subclinical changes.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Zhang S, Simard M, Lapointe A, et al. Evaluation of Radiation Dose Effect on Lung Function Using Iodine Maps Derived From Dual-Energy Computed Tomography. Int J Radiat Oncol Biol Phys. 2024. PMID: 38705488. doi:10.1016/j.ijrobp.2024.04.069

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。