文献速递胸部肿瘤放疗放疗物理与技术

持续与双水平气道正压通气或可改善胸腔内肿瘤患者的放疗实施

Continuous and bilevel positive airway pressure may improve radiotherapy delivery in patients with intra-thoracic tumors.
PubMed 文献 · Clin Transl Radiat Oncol · 2024-04-20

本研究在10例胸腔内肿瘤患者中测试不同CPAP/BiPAP设置,采用电阻抗断层成像评估呼气末肺阻抗与潮气阻抗变异。结果显示不同设置间呼气末肺阻抗差异显著,CPAP-15时增加最明显,潮气阻抗变异与呼吸变异性无显著差异。作者认为CPAP/BiPAP可行且耐受,较高后备呼吸频率的BiPAP可能最有潜力减轻肿瘤运动。

要点

  • 10例胸腔内肿瘤患者中9例耐受所有CPAP/BiPAP设置,1例无法维持CPAP-15。
  • 不同设置间呼气末肺阻抗差异显著(χ2 22.960,p < 0.001),CPAP-15时中位数(IQR)为1.03(1.00-1.06)。
  • 潮气阻抗变异与呼吸变异性在各设置间无显著差异。

核心结论

  • 在胸腔内肿瘤患者中应用不同CPAP/BiPAP设置是可行且可耐受的。
  • 在所应用的设置中,较高后备呼吸频率的BiPAP可能最有潜力减轻肿瘤运动,但作者指出尚需进一步开展研究肿瘤运动的工作。

研究设计与样本

  • 研究纳入10例患者(5例肺癌、5例其他胸腔内肿瘤),每例测试CPAP 5、10、15 cmH2O及BiPAP 14/10 cmH2O(较低后备呼吸频率7次/分与较高后备呼吸频率,后者初始为自主呼吸频率以上1次/分,若患者仍触发呼吸则可调整),每种设置测试10分钟。
  • 采用电阻抗断层成像分析呼气末肺阻抗(作为呼气末肺容量的估计)与潮气阻抗变异(作为潮气量的估计)。

主要发现

  • 10例患者中9例耐受所有设置,1例无法维持CPAP-15。
  • 不同设置间呼气末肺阻抗差异显著(χ2 22.960,p < 0.001),CPAP-15时增加最明显,中位数(IQR)为1.03(1.00-1.06),以自主呼吸时呼气末肺阻抗归一化。
  • 各设置间潮气阻抗变异与呼吸变异性无显著差异。

局限性

  • 原文指出尚需进一步开展研究肿瘤运动的工作。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Minimizing tumor motion in radiotherapy for intra-thoracic tumors reduces side-effects by limiting radiation exposure to healthy tissue. Continuous or Bilevel Positive Airway Pressure (CPAP/BiPAP) could achieve this, since it could increase lung inflation and decrease tidal volume variability. We aim to identify the better CPAP/BiPAP setting for minimizing tumor motion. METHODS: In 10 patients (5 with lung cancer, 5 with other intra-thoracic tumors), CPAP/BiPAP was tested with the following settings for 10 min each: CPAP 5, 10 and 15 cmH2O and BiPAP 14/10 cmH2O with a lower (7 breaths/min) and higher back-up respiratory rate (BURR initially 1 breath/min above the spontaneous breathing frequency, with the option to adjust if the patient continued to initiate breaths). Electrical impedance tomography was used to analyse end-expiratory lung impedance (EELI) as an estimate of end-expiratory lung volume and tidal impedance variation (TIV) as an estimate of tidal volume. RESULTS: Nine out of ten patients tolerated all settings; one patient could not sustain CPAP-15. A significant difference in EELI was observed between settings (χ2 22.960, p < 0.001), with most increase during CPAP-15 (median (IQR) 1.03 (1.00 - 1.06), normalized to the EELI during spontaneous breathing). No significant differences in TIV and breathing variability were found between settings. CONCLUSIONS: This study shows that the application of different settings of CPAP/BiPAP in patients with intra-thoracic tumors is feasible and tolerable. BiPAP with a higher BURR may offer the greatest potential for mitigating tumor motion among the applied settings, although further research investigating tumor motion should be conducted.

来源:Clin Transl Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Elshof J, Steenstra CM, Niezink AGH, et al. Continuous and bilevel positive airway pressure may improve radiotherapy delivery in patients with intra-thoracic tumors. Clin Transl Radiat Oncol. 2024. PMID: 38706725. doi:10.1016/j.ctro.2024.100784

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。