时间延迟对比增强扫描在确定大体积脑转移瘤大体肿瘤靶区体积中的作用
该前瞻性研究纳入155例初诊脑转移瘤患者(561个>1 cm病灶),在钆对比剂注射后1、3、5、10、18、20分钟行增强T1加权成像并勾画大体肿瘤靶区(GTV),以六期融合GTV-total为参考。结果显示不同延迟时间GTV边界和形状存在显著差异,作者结论认为GTV确定应采用时间延迟多期增强扫描,且≥10分钟时相为必需。
要点
- 与GTV-1min相比,GTV-3min至GTV-20min体积增加2.2%至10.6%(P<0.05)。
- 与GTV-total相比,各单期GTV体积减少10.3%至25.4%(P<0.05)。
- 作者结论认为GTV确定应采用时间延迟多期增强扫描,≥10分钟时相为必需。
核心结论
- 不同延迟时间的增强MR扫描在大体积脑转移瘤的边界和形状上显示出显著差异。
- 作者结论认为GTV确定应采用时间延迟多期对比增强扫描,且≥10分钟时相为必需。
研究设计与样本
- 前瞻性纳入155例初诊脑转移瘤患者,共561个>1 cm病灶。
- 在钆对比剂注射后1、3、5、10、18、20分钟行增强T1加权成像扫描,分别确定GTV-1min至GTV-20min。
- 将六个时相GTV融合定义为GTV-total,并设为参考GTV,比较不同延迟时间GTV与脑白质的体积、形状和信号强度。
主要发现
- 与GTV-1min相比,GTV-3min、GTV-5min、GTV-10min、GTV-18min、GTV-20min体积分别增加2.2%、3.8%、6.5%、9.5%、10.6%(P<0.05)。
- 与GTV-total相比,GTV-1min、GTV-3min、GTV-5min、GTV-10min、GTV-18min、GTV-20min体积分别减少25.4%、22.1%、18.7%、15.0%、11.2%、10.3%(P<0.05)。
- 与GTV-total相比,29个(51.8%)融合GTV体积减少率<5%,45个(80.4%)Dice相似系数>0.95,且均包含GTV-10min、GTV-18min或GTV-20min。
- GTV与脑白质的信号强度比在5分钟时达峰值(0.351±0.24)。
关键数值与推荐
- 作者结论认为GTV确定应采用时间延迟多期对比增强扫描,且≥10分钟时相为必需。
临床怎么用
- 作者结论认为脑转移瘤放疗GTV确定应采用时间延迟多期对比增强扫描,且≥10分钟时相为必需。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND AND PURPOSE: To assess the variation of large-volume brain metastases (BMs) boundaries and shapes using enhanced magnetic resonance (MR) scanning with different delay times and to provide a basis for determining the gross tumor target volume (GTV) for radiotherapy of BMs. MATERIALS AND METHODS: We prospectively enrolled 155 patients initially diagnosed with BMs (561 lesions > 1 cm). Contrast-enhanced (CE) T1-weighted imaging scans were performed 1, 3, 5, 10, 18, and 20 min after gadolinium-based contrast agent injection and GTVs were determined as GTV-1min, GTV-3min, GTV-5min, GTV-10min, GTV-18min, and GTV-20min, respectively, which were subsequently fused in different phases. Fusion of the six GTVs was defined as GTV-total, which was set as the reference GTV. The volume, shape, and signal intensity of the GTVs and brain white matter (BWM) were compared at different delay times. RESULTS: GTV-3min, GTV-5min, GTV-10min, GTV-18min, and GTV-20min volumes increased by 2.2 %, 3.8 %, 6.5 %, 9.5 %, and 10.6 %, respectively (P < 0.05) compared with GTV-1min. Compared with GTV-total, GTV-1min, GTV-3min, GTV-5min, GTV-10min, GTV-18min, and GTV-20min volumes reduced by 25.4 %, 22.1 %, 18.7 %, 15.0 %, 11.2 %, and 10.3 %, respectively (P < 0.05). Compared with GTV-total, 29 (51.8 %) fused GTVs had a volume reduction rate < 5 %, 45 (80.4 %) had a Dice similarity coefficient > 0.95, and all contained GTV-10min, GTV-18min or GTV-20min. The signal intensity ratio between the GTV and BWM peaked at 5 min (0.351 ± 0.24). CONCLUSION: Enhanced MR scans with different delay times show significant differences in the boundaries and shapes of large-volume BMs, and time-delayed multi-phase CE scanning should be used in GTV determination, with time phases ≥ 10 min being mandatory.
引用
- Du S, Gong G, Chen M, et al. The effect of time-delayed contrast-enhanced scanning in determining the gross tumor target volume of large-volume brain metastases. Radiother Oncol. 2024. PMID: 38768715. doi:10.1016/j.radonc.2024.110330
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。