一项评估调强放疗对即刻二期假体乳房再造乳腺癌患者假体失败率影响的II期研究及MRI影像相关子研究
单臂II期试验纳入2014年6月至2017年3月119例乳房切除加腋窝清扫后假体再造并接受调强放疗的乳腺癌患者,主要终点为永久假体置入24个月内假体失败率,若低于16%则优于历史对照。100例可评估者中25例发生假体失败,第1组(放疗至永久假体)8/42(19%),第2组(放疗至组织扩张器)17/58(29%),未优于传统三维适形方法。MRI形态学特征与Baker 3至4级包膜挛缩相关,但需更大样本验证。
要点
- 100例可评估患者中25例发生假体失败,第1组8/42(19%),第2组17/58(29%)。
- 假体失败率与历史三维适形方法相似,未达到低于16%的改善目标。
- 纵向MRI形态学特征与Baker 3至4级包膜挛缩相关,但需更大样本验证。
核心结论
- 接受调强放疗的乳房再造乳腺癌患者假体失败率与传统三维适形方法相似,但未优于后者。
- MRI特征有望预测包膜挛缩,但需在更大样本研究中验证。
研究设计与样本
- 单臂II期临床试验,纳入乳房切除加腋窝清扫后假体再造并接受调强放疗的乳腺癌患者。
- 主要终点为永久假体置入24个月内假体失败率,若低于16%则视为优于历史对照。
- 假体失败定义为取出导致胸壁平坦或更换为其他再造方式。
- 患者分为2组:第1组(RT-PI)放疗至永久假体,第2组(RT-TE)放疗至组织扩张器。
- 2014年6月至2017年3月共入组119例女性,第1组45例,第2组74例,可评估100例。
主要发现
- 100例可评估参与者中25例在研究期间发生假体失败,第1组8/42(19%),第2组17/58(29%)。
- 假体失败原因中,包膜挛缩13例、感染7例、外露3例、其他原因2例。
- 纵向MRI图像观察到的形态学形状特征与Baker 3至4级挛缩的发生相关。
局限性
- MRI特征虽有望预测包膜挛缩,但需在更大样本研究中验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Postmastectomy radiation therapy is a mainstay in the adjuvant treatment of node-positive breast cancer, but it poses risks for women with breast reconstruction. Multibeam intensity-modulated radiation therapy improves dose conformality and homogeneity, potentially reducing complications in breast cancer patients with implant-based reconstruction. To investigate this hypothesis, we conducted a single-arm phase 2 clinical trial of breast cancer patients who underwent mastectomy/axillary dissection and prosthesis-based reconstruction. METHODS AND MATERIALS: The primary endpoint was the rate of implant failure (IF) within 24 months of permanent implant placement, which would be considered an improvement over historical controls if below 16%. IF was defined as removal leading to a flat chest wall or replacement with another reconstruction. Patients were analyzed in 2 cohorts. Cohort 1 (RT-PI) received radiation therapy to the permanent implant. Cohort 2 (RT-TE) received radiation therapy to the TE. IF rates, adverse events, and quality of life were analyzed. Follow-up/postradiation therapy assessments were compared with the baseline/preradiation therapy assessments at 3 to 10 weeks after exchange surgery. A subgroup underwent serial magnetic resonance imaging (MRI) sessions to explore the association between MRI-detected changes and capsular contracture, a known adverse effect of radiation therapy. RESULTS: Between June 2014 and March 2017, 119 women were enrolled. Cohort 1 included 45 patients, and cohort 2 had 74 patients. Among 100 evaluable participants, 25 experienced IF during the study period. IF occurred in 8/42 (19%) and 17/58 (29%) in cohorts 1 and 2, respectively. Among the IFs, the majority were due to capsular contracture (13), infection (7), exposure (3), and other reasons (2). Morphologic shape features observed in longitudinal MRI images were associated with the development of Baker grade 3 to 4 contractures. CONCLUSIONS: The rate of IF in reconstructed breast cancer patients treated with intensity-modulated radiation therapy was similar to, but not improved over, that observed with conventional, 3-dimensional-conformal methods. MRI features show promise for predicting capsular contracture but require validation in larger studies.
引用
- Khan AJ, Marine CB, Flynn J, et al. A Phase II Study Evaluating the Effect of Intensity Modulated Postmastectomy Radiation Therapy on Implant Failure Rates in Breast Cancer Patients With Immediate, 2-Stage Implant Reconstruction With an MRI Imaging Correlative Substudy. Int J Radiat Oncol Biol Phys. 2024. PMID: 38570168. doi:10.1016/j.ijrobp.2024.03.031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。