文献速递乳腺癌放疗放疗物理与技术

剪切波弹性成像定量评估乳腺癌患者放疗诱导的乳腺纤维化:一项前瞻性研究12个月随访数据

Quantifying radiation-induced breast fibrosis by shear-wave elastography in patients with breast cancer: A 12-months-follow-up data of a prospective study.
PubMed 文献 · Clin Transl Radiat Oncol · 2024-03-30

这项前瞻性研究纳入41例保乳术后接受放疗的乳腺癌患者,在放疗前及放疗后3、12个月用剪切波弹性成像(SWE)和B型超声测量弹性值,并用CTCAE 5.0记录放疗诱导纤维化(RIF)。放疗前与放疗后12个月三个测量区域弹性值均有显著差异,12个月时RIF以1级为主(48.8%)。作者认为SWE可量化评估乳腺组织硬度,为RIF提供定量信息。

要点

  • 41例保乳术后放疗患者前瞻性随访,SWE测量瘤床、非瘤床及对侧乳腺弹性值。
  • 放疗后12个月CTCAE RIF分级:0级43.9%、1级48.8%、2级7.3%。

核心结论

  • 作者认为SWE能够评估组织硬度,为乳腺癌放疗诱导纤维化提供定量信息。
  • 作者指出需长期随访的进一步研究以提供更多定量数据。

研究设计与样本

  • 前瞻性研究,41例乳腺癌患者在放疗前入组。
  • 放疗前及放疗后3、12个月行SWE和B型超声测量弹性值。
  • 在患侧瘤床、患侧非瘤床及对侧乳腺测量最大弹性值,并用CTCAE 5.0记录RIF。

主要发现

  • 放疗前瘤床、非瘤床及对侧乳腺弹性值分别为71.2±74.9 kPa、19.4±9.8 kPa、20.3±10.0 kPa。
  • 放疗后12个月瘤床、非瘤床及对侧乳腺弹性值分别为28.7±26.3 kPa、15.1±7.0 kPa、14.7±6.3 kPa。
  • 放疗前与放疗后12个月弹性值在瘤床(p<0.001)、非瘤床(p=0.002)及对侧乳腺(p=0.001)均显著不同。
  • 放疗后12个月CTCAE RIF分级分布为0级43.9%、1级48.8%、2级7.3%。

关键数值与推荐

  • RIF采用CTCAE 5.0分级记录。
  • 定量测量采用瘤床、非瘤床及对侧乳腺的最大弹性值。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 作者指出需长期随访的进一步研究以提供更多定量数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To assess radiation-induced fibrosis (RIF) using shear-wave elastography (SWE) in patients with breast cancer who received radiotherapy (RT) after breast conserving surgery. METHODS: Forty-one patients were enrolled in a prospective study before RT. SWE and B-mode ultrasonography were performed to measure elasticity. For quantitative measurement, the maximum elasticity value was measured in the tumor bed and non-tumor bed of the treated breast, and contralateral breast before RT and at 3, and 12 months after RT. and RIF was recorded using the Common Terminology Criteria for Adverse Events (CTCAE) version 5.0. RESULTS: The mean ± standard deviation elasticity values for the tumor bed, non-tumor bed, and contralateral breast were 71.2 ± 74.9 kPa, 19.4 ± 9.8 kPa and 20.3 ± 10.0 kPa before RT; 28.7 ± 26.3 kPa, 15.1 ± 7.0 kPa, and 14.7 ± 6.3 kPa at 12 months after RT, respectively. The elasticity values for all three measurement areas before and 12 months after RT were significantly different (p < 0.001 for tumor bed, p = 0.002 for non-tumor bed, p = 0.001 for contralateral breast). At 12 months follow-up, the distribution of grades of RIF evaluated by CTCAE grade was grade 0 in 43.9 %, grade 1 in 48.8 %, and grade 2 in 7.3 %. CONCLUSION: We demonstrated that SWE enables the evaluation of tissue stiffness to provide quantified information for the RIF of breast cancer. Further studies with long-term follow-up should provide more quantitative data.

来源:Clin Transl Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Jung W, Chung J, Lee J, et al. Quantifying radiation-induced breast fibrosis by shear-wave elastography in patients with breast cancer: A 12-months-follow-up data of a prospective study. Clin Transl Radiat Oncol. 2024. PMID: 38590328. doi:10.1016/j.ctro.2024.100773

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。