文献速递乳腺癌放疗放疗物理与技术

持续气道正压通气与深吸气屏气在左侧乳腺癌放疗中的剂量学比较

Dosimetric Comparison of CPAP and DIBH for Left-sided Breast Cancer Radiation Therapy.
PubMed 文献 · Adv Radiat Oncol · 2024-02-17

本研究回顾性收集35例左侧乳腺癌患者的计划CT,比较自由呼吸、10 cmH2O持续气道正压通气(CPAP)与深吸气屏气(DIBH)三种呼吸条件下容积旋转调强计划的剂量学与几何差异。CPAP与DIBH的平均心脏剂量均为1.05 Gy,显著低于自由呼吸的1.34 Gy;左前降支最大剂量在CPAP计划中最小。作者认为CPAP在剂量学与几何方面与DIBH相似,可能作为DIBH的替代方案。

要点

  • CPAP与DIBH平均心脏剂量均为1.05 Gy,显著低于自由呼吸的1.34 Gy。
  • 左前降支最大剂量CPAP为4.44 Gy,低于DIBH的4.73 Gy与自由呼吸的7.33 Gy。
  • CPAP与DIBH在心脏-CTV最小距离上无显著差异,DIBH肺体积最大。

核心结论

  • CPAP与DIBH在几何和剂量学方面表现相似,为CPAP在放疗中的有效性和可行性提供了有力证据,提示其可能作为左侧乳腺癌患者DIBH的替代方案。

研究设计与样本

  • 回顾性计划研究,收集35例左侧乳腺癌患者在自由呼吸、CPAP(10 cmH2O压力)和DIBH三种呼吸条件下的计划CT。
  • 容积旋转调强计划目标为95%处方剂量覆盖95%计划靶区体积,最大剂量低于107%。
  • 对三种计划进行剂量学比较分析,并通过计算每幅计划CT中心脏与临床靶区(CTV)的最小距离评估几何差异。

主要发现

  • CPAP与DIBH计划平均心脏剂量均为1.05 Gy,显著低于自由呼吸计划的1.34 Gy。
  • 左前降支最大剂量在CPAP计划中最小(4.44 Gy),其次为DIBH(4.73 Gy)和自由呼吸(7.33 Gy)。
  • CPAP与DIBH的其他危及器官剂量相似:平均对侧乳腺剂量分别为2.27 Gy和2.21 Gy,平均同侧肺剂量分别为4.09 Gy和4.08 Gy,V20分别为6.11%和6.31%,平均对侧肺剂量分别为0.94 Gy和0.92 Gy。
  • CPAP与DIBH之间心脏-CTV最小距离无显著差异。
  • DIBH肺体积最大(3908 cc),其次为CPAP(3509 cc)和自由呼吸(2703 cc)。

临床怎么用

  • 作者认为CPAP在剂量学与几何方面与DIBH相似,提示其可能作为左侧乳腺癌患者DIBH的替代方案。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Despite the increasing interest in using continuous positive airway pressure (CPAP) in radiation therapy (RT), direct comparisons with the more widely used deep inspiration breath-hold (DIBH) have been limited. This planning study aimed to offer comprehensive geometric and dosimetric evidence by comparing CPAP and DIBH-based RT plans. MATERIALS AND METHODS: A retrospective data set of 35 patients with left-sided breast cancer with planning computed tomography scans under three breathing conditions (free breathing (FB), CPAP with 10 cmH2O pressure, and DIBH) was collected. Volumetric arc therapy plans aimed for 95% dose coverage to 95% of the planning target volume with a maximum dose below 107%. A comparative dosimetric analysis among the three plans was conducted. Additionally, geometric differences were assessed by calculating the minimum distance between the heart and the clinical target volume (CTV) in each planning computed tomography. RESULTS: CPAP and DIBH plans demonstrated comparable mean heart doses (1.05 Gy), which were significantly lower than the FB plan (1.34 Gy). The maximum dose to the left anterior descending artery was smallest in the CPAP plan (4.44 Gy), followed by DIBH (4.73 Gy) and FB (7.33 Gy) plans. Other organ-at-risk doses for CPAP and DIBH were similar, with mean contralateral breast doses of 2.27 and 2.21 Gy, mean ipsilateral lung doses of 4.09 and 4.08 Gy, V20 at 6.11% and 6.31%, and mean contralateral lung doses of 0.94 and 0.92 Gy, respectively. No significant difference was found in the minimum heart-to-CTV distance between CPAP and DIBH. DIBH exhibited the greatest lung volume (3908 cc), followed by CPAP (3509 cc), and FB(2703 cc). CONCLUSIONS: The comparison between CPAP and DIBH shows their similarity in both geometric and dosimetric aspects, providing strong evidence for CPAP's effectiveness and feasibility in RT. This suggests its potential as an alternative to DIBH for patients with left-sided breast cancer.

来源:Adv Radiat Oncol,查看原文。版权归原作者所有。

引用

  1. Choi MS, Park RH, Lee J, et al. Dosimetric Comparison of CPAP and DIBH for Left-sided Breast Cancer Radiation Therapy. Adv Radiat Oncol. 2024. PMID: 38681894. doi:10.1016/j.adro.2024.101478

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。