基于人工智能的前列腺癌放射治疗计划CT器官勾画
研究纳入2006至2018年接受根治性放疗的1530例前列腺癌患者,约50%CT用于训练、25%验证、25%测试,评估人工智能自动勾画前列腺及危及器官与人工勾画的一致性。结果显示前列腺、膀胱、直肠的中位Sørensen-Dice相似系数分别为0.82、0.95、0.88,结论认为基于CT的自动勾画可行且与人工勾画一致性良好。
要点
- 前列腺、膀胱、直肠的中位Sørensen-Dice相似系数分别为0.82、0.95、0.88。
- 前列腺、膀胱、直肠的中位平均表面距离分别为1.7、0.7、1.1 mm。
- 前列腺、膀胱、直肠的中位Hausdorff距离分别为9.2、6.7、13.5 mm。
核心结论
- 基于CT的前列腺癌放射治疗计划自动器官勾画可行,且与人工勾画一致性良好。
研究设计与样本
- 研究纳入2006至2018年接受根治性放疗的1530例前列腺癌患者的前列腺、膀胱和直肠人工勾画。
- 约50%的CT扫描用作训练集、25%用作验证集、25%用作测试集。
- 因金属伪影排除有髋关节假体的患者。
- 经训练和验证集微调后,在测试集上获得前列腺和危及器官的自动勾画。
- 采用Sørensen-Dice相似系数、平均表面距离和Hausdorff距离评估人工与自动勾画的一致性。
主要发现
- 人工与人工智能勾画之间的中位Sørensen-Dice相似系数:前列腺0.82、膀胱0.95、直肠0.88。
- 中位平均表面距离:前列腺1.7 mm、膀胱0.7 mm、直肠1.1 mm。
- 中位Hausdorff距离:前列腺9.2 mm、膀胱6.7 mm、直肠13.5 mm。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Meticulous manual delineations of the prostate and the surrounding organs at risk are necessary for prostate cancer radiation therapy to avoid side effects to the latter. This process is time consuming and hampered by inter- and intraobserver variability, all of which could be alleviated by artificial intelligence (AI). This study aimed to evaluate the performance of AI compared with manual organ delineations on computed tomography (CT) scans for radiation treatment planning. METHODS AND MATERIALS: Manual delineations of the prostate, urinary bladder, and rectum of 1530 patients with prostate cancer who received curative radiation therapy from 2006 to 2018 were included. Approximately 50% of those CT scans were used as a training set, 25% as a validation set, and 25% as a test set. Patients with hip prostheses were excluded because of metal artifacts. After training and fine-tuning with the validation set, automated delineations of the prostate and organs at risk were obtained for the test set. Sørensen-Dice similarity coefficient, mean surface distance, and Hausdorff distance were used to evaluate the agreement between the manual and automated delineations. RESULTS: The median Sørensen-Dice similarity coefficient between the manual and AI delineations was 0.82, 0.95, and 0.88 for the prostate, urinary bladder, and rectum, respectively. The median mean surface distance and Hausdorff distance were 1.7 and 9.2 mm for the prostate, 0.7 and 6.7 mm for the urinary bladder, and 1.1 and 13.5 mm for the rectum, respectively. CONCLUSIONS: Automated CT-based organ delineation for prostate cancer radiation treatment planning is feasible and shows good agreement with manually performed contouring.
引用
- Polymeri E, Johnsson ÅA, Enqvist O, et al. Artificial Intelligence-Based Organ Delineation for Radiation Treatment Planning of Prostate Cancer on Computed Tomography. Adv Radiat Oncol. 2023. PMID: 38495038. doi:10.1016/j.adro.2023.101383
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。