本研究从全外显子测序中筛选与≥3级放射性肺炎相关的单核苷酸多态性(SNP),用因子机(FM)建模SNP上位效应,并加入剂量组学特征构建双组学模型。SNP-FM模型在测试组AUC为0.76,加入4个剂量组学特征后AUC升至0.81,提示该模型在识别胸部放疗期间重度放射性肺炎方面具有临床潜力。

要点

  • 从28例≥3级与28例匹配的≤1级放射性肺炎患者外周血中筛选出81个差异显著SNP(P<0.015)。
  • 19个SNP的SNP-SNP交互(上位效应)经FM建模,测试组AUC为0.76。
  • 加入4个剂量组学特征后双组学模型AUC升至0.81。

核心结论

  • 通过协同SNP上位效应与剂量组学特征构建了一种新型双组学模型,其增强的放射性肺炎预测能力提示在胸部放疗期间识别重度放射性肺炎患者方面具有临床潜力。

研究设计与样本

  • 从全外显子测序SNP中采用Fisher精确检验筛选在≥3级与≤1级放射性肺炎组间差异显著的潜在SNP,2009至2016年在本机构接受胸部放疗的肺癌患者纳入SNP筛选与模型构建。
  • 采用因子机(FM)方法建模SNP上位效应并构建放射性肺炎预测模型(SNP-FM),剂量组学特征经最小冗余最大相关(mRMR)方法筛选后加入SNP-FM模型构建双组学模型。
  • SNP筛选阶段对28例≥3级放射性肺炎与匹配的28例≤1级放射性肺炎患者外周血样本进行测序,模型构建阶段纳入400例合格患者(含108例≥2级放射性肺炎)。

主要发现

  • 81个SNP差异显著(P<0.015)被视为潜在SNP,另纳入21个放射毒性相关SNP。
  • 单个SNP与放射性肺炎无强相关性。
  • 19个SNP的SNP-SNP交互(上位效应)经FM方法建模,在测试组达到AUC 0.76。
  • 筛选出4个剂量组学特征加入模型后,AUC增至0.81。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Radiation pneumonitis (RP) is the major dose-limiting toxicity of thoracic radiotherapy. This study aimed to developed a dual-omics (single nucleotide polymorphisms, SNP and dosiomics) prediction model for symptomatic RP. MATERIALS AND METHODS: The potential SNPs, which are of significant difference between the RP grade ≥ 3 group and the RP grade ≤ 1 group, were selected from the whole exome sequencing SNPs using the Fisher's exact test. Patients with lung cancer who received thoracic radiotherapy at our institution from 2009 to 2016 were enrolled for SNP selection and model construction. The factorization machine (FM) method was used to model the SNP epistasis effect, and to construct the RP prediction model (SNP-FM). The dosiomics features were extracted, and further selected using the minimum redundancy maximum relevance (mRMR) method. The selected dosiomics features were added to the SNP-FM model to construct the dual-omics model. RESULTS: For SNP screening, peripheral blood samples of 28 patients with RP grade ≥ 3 and the matched 28 patients with RP grade ≤ 1 were sequenced. 81 SNPs were of significant difference (P < 0.015) and considered as potential SNPs. In addition, 21 radiation toxicity related SNPs were also included. For model construction, 400 eligible patients (including 108 RP grade ≥ 2) were enrolled. Single SNP showed no strong correlation with RP. On the other hand, the SNP-SNP interaction (epistasis effect) of 19 SNPs were modeled by the FM method, and achieved an area under the curve (AUC) of 0.76 in the testing group. In addition, 4 dosiomics features were selected and added to the model, and increased the AUC to 0.81. CONCLUSIONS: A novel dual-omics model by synergizing the SNP epistasis effect with dosiomics features was developed. The enhanced the RP prediction suggested its promising clinical utility in identifying the patients with severe RP during thoracic radiotherapy.