文献速递消化道肿瘤放疗放疗物理与技术

基于对比增强计算机断层扫描图像的深度学习用于食管癌大体肿瘤体积自动勾画:一项多机构研究

Deep Learning for Automatic Gross Tumor Volumes Contouring in Esophageal Cancer Based on Contrast-Enhanced Computed Tomography Images: A Multi-Institutional Study.
PubMed 文献 · Int J Radiat Oncol Biol Phys · 2024-03-02

该多机构研究回顾性收集580例食管鳞状细胞癌(ESCC)患者的对比增强CT图像,开发三维深度学习模型自动勾画大体肿瘤体积(GTV),并在3个验证队列中进行内外部验证。AI工具在 multicenter 验证队列中中位DSC为0.865、0.876、0.866,中位平均表面距离为0.939、0.789、0.875 mm,可改善部分专家勾画性能并减少观察者间变异。

要点

  • AI工具在多中心验证队列中勾画GTV的中位DSC为0.865、0.876、0.866。
  • AI工具使12名认证专家中半数勾画性能显著提升(DSC 0.794-0.835 vs 0.856-0.881,P=0.003-0.048)。
  • AI勾画减少观察者内和观察者间变异分别达37.4%和55.2%,节省勾画时间77.6%。

核心结论

  • AI勾画工具可改善ESCC患者的GTV勾画性能并促进放射组学分析,提示其在放疗计划设计和放射组学研究中的潜力。

研究设计与样本

  • 多机构回顾性研究,回顾性收集580例符合条件的ESCC患者的对比增强CT图像,由2名专家共识勾画的GTV轮廓作为参考标准。
  • 开发三维深度学习模型用于GTV勾画,在训练队列中开发并在3个验证队列中进行内部和外部验证。
  • 从外部验证队列中随机选取25例患者,将AI工具与12名认证专家进行比较,评估其辅助改善勾画性能和减少变异的能力。

主要发现

  • AI工具在多中心验证队列中表现出良好的GTV勾画性能,中位DSC分别为0.865、0.876、0.866,中位平均表面距离分别为0.939、0.789、0.875 mm。
  • AI工具显著改善了12名认证专家中半数的勾画性能(DSC值0.794-0.835 vs 0.856-0.881,P=0.003-0.048)。
  • AI工具分别减少观察者内和观察者间变异37.4%和55.2%,节省勾画时间77.6%。
  • 在放射组学分析中,参考标准与AI生成轮廓的88.7%放射组学特征表现出稳定的可重复性,且这些轮廓的病理完全缓解预测性能相似(P=0.430)。

关键数值与推荐

  • 勾画性能采用Dice相似系数(DSC)和平均表面距离衡量。
  • AI工具与12名认证专家在25例随机选取的外部验证队列患者中比较,DSC值0.794-0.835 vs 0.856-0.881,P=0.003-0.048。
  • 放射组学分析中,88.7%的放射组学特征表现出稳定的可重复性,病理完全缓解预测性能相似(P=0.430)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To develop and externally validate an automatic artificial intelligence (AI) tool for delineating gross tumor volume (GTV) in patients with esophageal squamous cell carcinoma (ESCC), which can assist in neo-adjuvant or radical radiation therapy treatment planning. METHODS AND MATERIALS: In this multi-institutional study, contrast-enhanced CT images from 580 eligible ESCC patients were retrospectively collected. The GTV contours delineated by 2 experts via consensus were used as ground truth. A 3-dimensional deep learning model was developed for GTV contouring in the training cohort and internally and externally validated in 3 validation cohorts. The AI tool was compared against 12 board-certified experts in 25 patients randomly selected from the external validation cohort to evaluate its assistance in improving contouring performance and reducing variation. Contouring performance was measured using dice similarity coefficient (DSC) and average surface distance. Additionally, our previously established radiomics model for predicting pathologic complete response was used to compare AI-generated and ground truth contours, to assess the potential of the AI contouring tool in radiomics analysis. RESULTS: The AI tool demonstrated good GTV contouring performance in multicenter validation cohorts, with median DSC values of 0.865, 0.876, and 0.866 and median average surface distance values of 0.939, 0.789, and 0.875 mm, respectively. Furthermore, the AI tool significantly improved contouring performance for half of 12 board-certified experts (DSC values, 0.794-0.835 vs 0.856-0.881, P = .003-0.048), reduced the intra- and interobserver variations by 37.4% and 55.2%, respectively, and saved contouring time by 77.6%. In the radiomics analysis, 88.7% of radiomic features from ground truth and AI-generated contours demonstrated stable reproducibility, and similar pathologic complete response prediction performance for these contours (P = .430) was observed. CONCLUSIONS: Our AI contouring tool can improve GTV contouring performance and facilitate radiomics analysis in ESCC patients, which indicates its potential for GTV contouring during radiation therapy treatment planning and radiomics studies.

来源:Int J Radiat Oncol Biol Phys,查看原文。版权归原作者所有。

引用

  1. Zhang S, Li K, Sun Y, et al. Deep Learning for Automatic Gross Tumor Volumes Contouring in Esophageal Cancer Based on Contrast-Enhanced Computed Tomography Images: A Multi-Institutional Study. Int J Radiat Oncol Biol Phys. 2024. PMID: 38432286. doi:10.1016/j.ijrobp.2024.02.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。